Introduction: The purpose of this research is to determine the accuracy and reliability of measurements obtained from 3-dimensional (3D) cone-beam computed tomography (CBCT) for different head orientations. Methods: Stainless steel wires were fixed to a dry skull at different places. The skull was scanned by using CBCT in the centered and 5 other positions. Intraobserver and interobserver reliability tests were performed by using 6 landmarks identified on the virtual 3D skulls by 2 operators. Two methods were used to determine the accuracy of measurements on the virtual 3D skull scanned in different positions. In the first method, 12 linear distances were compared on the physical skull and the 3D virtual skull in the centered and the other scanning positions. In the second method, registration of each of the 5 positions on the centered position was done separately, and coordinates of 11 landmarks were identified in each position and compared with the centered position. Data gathered from the 2 methods were compared statistically. Results: Concordance correlation and Pearson correlation coefficients values were almost 0.9999 in all the comparisons denoting: (1) high intraobserver and interobserver reliability; (2) very high concordance between the physical skull and the CBCT centered-position measurements; (3) very high concordance between measurements of the centered position in relation to those obtained from the different skull positions; and (4) registration of the skulls in the different positions showed high concordance, with the highest values between the centered and off-centered positions, and the lowest with the complex position. Conclusions: Accuracy and reliability of CBCT measurements are not affected by changing the skull orientation. Thus, the upper-lip and chin rests should not be considered absolute requirements during CBCT imaging if a stable head position is ensured. (Am J Orthod Dentofacial Orthop 2011;140:157-65)
引用
收藏
页码:157 / 165
页数:9
相关论文
共 21 条
[1]   Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull [J].
Berco, Mauricio ;
Rigali, Paul H., Jr. ;
Miner, R. Matthew ;
DeLuca, Stephelynn ;
Anderson, Nina K. ;
Will, Leslie A. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) :17.e1-17.e9
[2]  
BIANCHI S, 2003, DENTOMAXILLOFAC RAD, V30, pS28
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
CALVALCANTI MG, 1999, J ORAL MAXILLOFAC SU, V57, P690
[5]   Loss of anchorage of miniscrews: A 3-dimensional assessment [J].
El-Beialy, Amr Ragab ;
Abou-El-Ezz, Amr Mohamed ;
Attia, Khaled Hazem ;
El-Bialy, Ahmad Mohamed ;
Mostafa, Yehya Ahmed .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (05) :700-707
[6]  
Farman A.G., 2009, Semi-nars in Orthodontics, V15, P2, DOI DOI 10.1053/J.S0D0.2008.09.001
[7]   A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine [J].
Hashimoto, K ;
Arai, Y ;
Iwai, K ;
Araki, M ;
Kawashima, S ;
Terakado, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2003, 95 (03) :371-377
[8]  
HASSAN B, 2008, EUR J ORTHODONT, V23, P1
[9]   Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography [J].
Hilgers, ML ;
Scarfe, WC ;
Scheetz, JP ;
Farman, AG .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (06) :803-811
[10]   Three-dimensional cone beam computerized tomography in orthodontics [J].
Kau, C. H. ;
Richmond, S. ;
Palomo, J. M. ;
Hans, M. G. .
JOURNAL OF ORTHODONTICS, 2005, 32 (04) :282-293