Propionibacterium acnes lacks the capability to proliferate in platelet concentrates

被引:52
作者
Stoermer, M. [1 ]
Kleesiek, K. [1 ]
Dreier, J. [1 ]
机构
[1] Ruhr Univ Bochum, Univ Klinikum Ruhr, Herz & Diabet Zentrum Nordrhein Westfalen, Inst Labs & Transfus Med, D-32545 Bad Oeynhausen, Germany
关键词
automated culture; bacterial detection; platelet contamination; Propionibacterium acnes; sterility testing;
D O I
10.1111/j.1423-0410.2007.01019.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives Propionibacterium acnes is considered to be one of the most frequent contaminants of platelet concentrates (PCs) when anaerobic culture-based detection methods are used. But Propionibacteria are often detected too late when blood products have already been transfused. Therefore, its transfusion relevance is still demanding clarification because studies of the outcome of patients transfused with P. acnes-contaminated PCs are still uncommon. In this study, we monitored clinical effects in patients after transfusion of PCs, which were detected too late in sterility testing. Furthermore, we assessed the bacterial proliferation of Propionibacterium species seeded into PCs to clarify their significance for platelet bacteria screening. Materials and Methods In the look-back process, we followed the route of the putative contaminated PC units from storage to transfusion. In the in vitro study, PCs were inoculated with 1-100 colony-forming unit (CFU)/ml of clinical isolates of Propionibacteria (n = 10). Sampling was performed during 10-day aerobic storage at 22 degrees C. The presence of bacteria was assessed by plating culture and automated BacT/Alert culture system. Results Propionibacterium acnes shows slow or no growth under PC storage conditions. Clinical signs of adverse events after transfusion of potentially contaminated PC units were not reported. Conclusion Propionibacteria do not proliferate under PC storage conditions and therefore may be missed or detected too late when blood products have already been transfused.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 45 条
[1]   The reliability of bacterial detection in platelets [J].
AuBuchon, J. P. .
ISBT SCIENCE SERIES, VOL 1, NO 1: STATE OF THE ART PRESENTATIONS, 2006, 1 (01) :59-63
[2]   The residual risk of sepsis: modeling the effect of concentration on bacterial detection in two-bottle culture systems and an estimation of false-negative culture rates [J].
Benjamin, Richard J. ;
Wagner, Stephen J. .
TRANSFUSION, 2007, 47 (08) :1381-1389
[3]   Bacterial detection of platelets: Current problems and possible resolutions [J].
Blajchman, MA ;
Beckers, EAM ;
Dickmeiss, E ;
Lin, L ;
Moore, G ;
Muylle, L .
TRANSFUSION MEDICINE REVIEWS, 2005, 19 (04) :259-272
[4]   Improving the bacteriological safety of platelet transfusions [J].
Blajchman, MA ;
Goldman, M ;
Baeza, F .
TRANSFUSION MEDICINE REVIEWS, 2004, 18 (01) :11-24
[5]   Investigation of an isolate of Staphylococcus lugdunensis implicated in a platelet fatality:: a possible advantage of the use of an anaerobic bottle [J].
Brecher, Mark E. ;
Hay, Shauna N. .
TRANSFUSION, 2007, 47 (08) :1390-1394
[6]   Growth of bacteria in inoculated platelets: implications for bacteria detection and the extension of platelet storage [J].
Brecher, ME ;
Holland, PV ;
Pineda, AA ;
Tegtmeier, GE ;
Yomtovian, R .
TRANSFUSION, 2000, 40 (11) :1308-1312
[7]   Evaluation of an automated culture system for detecting bacterial contamination of platelets: an analysis with 15 contaminating organisms [J].
Brecher, ME ;
Means, N ;
Jere, CS ;
Heath, D ;
Rothenberg, S ;
Stutzman, LC .
TRANSFUSION, 2001, 41 (04) :477-482
[8]   Evaluation of a new generation of culture bottle using an automated bacterial culture system for detecting nine common contaminating organisms found in platelet components [J].
Brecher, ME ;
Heath, DG ;
Hay, SN ;
Rothenberg, SJ ;
Stutzman, LC .
TRANSFUSION, 2002, 42 (06) :774-779
[9]   Effects of skin disinfection method, deviation bag, and bacterial screening on clinical safety of platelet transfusions in the Netherlands [J].
de Korte, D ;
Curvers, J ;
de Kort, WLAM ;
Hoekstra, T ;
van der Poel, CL ;
Beckers, EAM ;
Marcelis, JH .
TRANSFUSION, 2006, 46 (03) :476-485
[10]   Two novel real-time reverse transcriptase PCR assays for rapid detection of bacterial contamination in platelet concentrates [J].
Dreier, J ;
Störmer, M ;
Kleesiek, K .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (10) :4759-4764