Quantification in MALDI-TOF mass spectrometry of modified polymers

被引:29
|
作者
Walterova, Zuzana [1 ]
Horsky, Jiri [1 ]
机构
[1] Acad Sci Czech Republ, Inst Macromol Chem, Dept Separat & Transport Macromol, CR-16206 Prague 6, Czech Republic
关键词
MALDI-TOF mass spectrometry; Modified polymers; Quantification; Internal standard; Standard-addition method; POLYDISPERSE POLYMERS; QUANTITATIVE-ANALYSIS; SYNTHETIC-POLYMERS; DISCRIMINATION;
D O I
10.1016/j.aca.2011.03.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
MALDI-TOF mass spectrometry quantification is hampered by the poor reproducibility of the signal intensity and by molecular-mass and compositional discrimination. The addition of a suitable compound as an internal standard increases reproducibility and allows a calibration curve to be constructed. The concept was also verified with synthetic polymers but no instructions for practical implementation were given [H. Chen, M. He, J. Pei, H. He, Anal. Chem. 75 (2003) 6531-6535.], even though synthetic polymers are generally non-uniform with respect to molecular mass and composition and access to the polymer of the same molecular mass distribution and composition as that of the quantified one is thus the exception rather than rule. On the other hand, relative quantification of polymers e.g., the content of the precursor polymer in a batch of a modified polymer, is usually sought. In this particular case, the pure precursor is usually available and the modified polymer can serve as an internal standard. However, the calibration curve still cannot be constructed and the use of the internal standard has to be combined with the method of standard addition in which the precursor polymer is added directly to the analyzed sample. The experiments with simulated modified polymers, mixtures of poly(ethylene glycol) (PEG) and poly(ethylene glycol) monomethyl ether (MPEG) of similar molecular-mass distribution, revealed a power dependence of the PEG/MPEG signal-intensity ratio (MS ratio) on the PEG/MPEG concentrations ratio in the mixture (gravimetric ratio). The result was obtained using standard procedures and instrumentation, which means that the basic assumption of the standard-addition method, i.e., the proportionality of the MS and gravimetric ratios, generally cannot be taken for granted. Therefore, the multi-point combined internal-standard standard-addition method was developed and experimentally verified for the quantification of the precursor in modified polymers. In this method, the two parameters of the power-type calibration curve - the proportionality constant and the exponent-are assumed. If the exponent strongly deviates from unity the minority component can be significantly underrepresented in the spectrum. Therefore, the absence of the precursor polymer signals in the MALDI-TOF mass spectrum of a modified polymer sample does not prove the absence of the precursor in the sample. Such a conclusion has to be corroborated by the standard-addition method. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [1] Quantification of nitroaromatic explosives in contaminated soil using MALDI-TOF mass spectrometry
    Kober, S. Liane
    Hollert, Henner
    Frohme, Marcus
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (23) : 5993 - 6003
  • [2] Quantification of Polyethylene Glycol 400 Excreted in the Urine by MALDI-TOF Mass Spectrometry
    Kuki, Akos
    Hashimov, Mahir
    Nagy, Tibor
    Toth, Csaba
    Zsuga, Miklos
    Keki, Sandor
    PHARMACEUTICS, 2022, 14 (07)
  • [3] Quantification of thaumatin-like proteins in white wine using MALDI-TOF mass spectrometry
    Raskova, Michaela
    Perutka, Zdenek
    Marchetti-Deschmann, Martina
    Sebela, Marek
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2024, 250 (01) : 69 - 81
  • [4] Quantification of thaumatin-like proteins in white wine using MALDI-TOF mass spectrometry
    Michaela Rašková
    Zdeněk Perutka
    Martina Marchetti-Deschmann
    Marek Šebela
    European Food Research and Technology, 2024, 250 (1) : 69 - 81
  • [5] Quantitative MALDI-TOF Mass Spectrometry of Star-Shaped Polylactides Based on Chromatographic Hyphenation
    Falkenhagen, Jana
    Dalgic, Mete-Sungur
    Weidner, Steffen M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2025, 36 (03) : 613 - 621
  • [6] MALDI-TOF Mass Spectrometry: Any Use for Aspergilli?
    Maurizio Sanguinetti
    Brunella Posteraro
    Mycopathologia, 2014, 178 : 417 - 426
  • [7] MALDI-TOF Mass Spectrometry: Any Use for Aspergilli?
    Sanguinetti, Maurizio
    Posteraro, Brunella
    MYCOPATHOLOGIA, 2014, 178 (5-6) : 417 - 426
  • [8] MALDI-TOF Mass Spectrometry as the Tool for the Identification of Features of Polymers Obtained by Inverse Vulcanization
    Tarasova, Natalia
    Krivoborodov, Efrem
    Kirakosian, Diana
    Zanin, Alexey
    Toropygin, Ilya
    Mezhuev, Yaroslav
    MACROMOL, 2024, 4 (04): : 856 - 870
  • [9] Detection of antibacterial resistance by MALDI-TOF mass spectrometry
    Zboromyrska, Yuliya
    Ferrer-Navarro, Mario
    Marco, Francesc
    Vila, Jordi
    REVISTA ESPANOLA DE QUIMIOTERAPIA, 2014, 27 (02) : 87 - 92
  • [10] Characterization of Prokaryotes Using MALDI-TOF Mass Spectrometry
    Dridi, B. Bedis
    Drancourt, Michel
    METHODS IN MICROBIOLOGY, VOL 38: TAXONOMY OF PROKARYOTES, 2011, 38 : 283 - 297