Surface damage of dental implant systems and ions release after exposure to fluoride and hydrogen peroxide

被引:28
|
作者
Penarrieta-Juanito, Gabriella [1 ]
Sordi, Mariane B. [1 ]
Henriques, Bruno [2 ,3 ]
Dotto, Marta E. R. [4 ]
Teughels, Wim [5 ]
Silva, Filipe S. [3 ]
Magini, Ricardo S. [1 ]
Souza, Julio C. M. [3 ]
机构
[1] Fed Univ Santa Catarina UFSC, Div Implant Dent, Dept Dent, Postgrad Program Dent PPGO, Florianopolis, SC, Brazil
[2] Fed Univ Santa Catarina UFSC, Dept Mech Engn EMC, Lab Ceram & Composite Mat CERMAT, Florianopolis, SC, Brazil
[3] Univ Minho, Ctr Microelectromech Syst CMEMS UMINHO, Guimaraes, Portugal
[4] Fed Univ Santa Catarina UFSC, Dept Phys, Florianopolis, SC, Brazil
[5] Katholieke Univ Leuven, Univ Hosp Leuven, Dept Oral Hlth Sci, Leuven, Belgium
关键词
corrosion; fluoride; hydrogen peroxide; roughness; titanium; CORROSION BEHAVIOR; PURE TITANIUM; RESISTANCE; ALLOYS; WEAR; PH;
D O I
10.1111/jre.12603
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective The aim of this study was to evaluate surface changes on dental implant systems and ions release after immersion in fluoride and hydrogen peroxide. Methods Ten implant-abutment assemblies were embedded in acrylic resin and cross-sectioned along the implant vertical axis. Samples were wet ground and polished. Delimited areas of groups of samples were immersed in 1.23% sodium fluoride gel (F) or in 35% hydrogen peroxide (HP) for 16 min. Gels (n = 3) were collected from the implant surfaces and analyzed by inductively coupled plasma mass spectrometry (ICP-MS), to detect the concentration of metallic ions released from the implant systems. Selected areas of the abutment and implant (n = 15) were analyzed by atomic force microscopy (AFM) and scanning electron microscopy (SEM). Results SEM images revealed surface topographic changes on implant-abutment joints after immersion in fluoride. Implants showed excessive oxidation within loss of material, while abutment surfaces revealed intergranular corrosion after immersion in fluoride. ICP-MS results revealed a high concentration of Ti, Al, V ions in fluoride after contact with the implant systems. Localized corrosion of implant systems could not be detected by SEM after immersion in hydrogen peroxide although the profilometry showed increase in roughness. ICP-MS showed the release of metallic ions in hydrogen peroxide medium after contact with dental implants. Conclusion Therapeutical substances such as fluorides and hydrogen peroxide can promote the degradation of titanium-based dental implant and abutments leading to the release of toxic ions.
引用
收藏
页码:46 / 52
页数:7
相关论文
共 50 条
  • [1] The effect of different oxidizing ions on hydrogen peroxide treatment of titanium dental implant
    Khodaei, Mohammad
    Kelishadi, Saleh Hossein
    SURFACE & COATINGS TECHNOLOGY, 2018, 353 : 158 - 162
  • [2] Surface reaction of titanium oxide film to fluoride and hydrogen peroxide in simulated oral environment
    Takemoto, Shinji
    Hattori, Masayuki
    Yoshinari, Masao
    Kawada, Eiji
    Oda, Yutaka
    BIOCERAMICS 21, 2009, 396-398 : 373 - 376
  • [3] Influence of Fluoride Content of Artificial Saliva on Metal Release from 17-4 PH Stainless Steel Foam for Dental Implant Applications
    Mutlu, Ilven
    Oktay, Enver
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2013, 29 (06) : 582 - 588
  • [4] Surface Damage on Dental Implants with Release of Loose Particles after Insertion into Bone
    Senna, Plinio
    Cury, Altair Antoninha Del Bel
    Kates, Stephen
    Meirelles, Luiz
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (04) : 681 - 692
  • [5] Particle release from dental implants immediately after placement - An ex vivo comparison of different implant systems
    Barrak, Fadi
    Li, Siwei
    Muntane, Albert
    Bhatia, Manoj
    Crossthwaite, Kathryn
    Jones, Julian
    DENTAL MATERIALS, 2022, 38 (06) : 1004 - 1014
  • [6] Degradation of dental implant systems after immersion in therapeutic gels
    Juanito, G. M. P.
    Araujo, M. S.
    Magini, R. S.
    Souza, J. C. M.
    Dotto, M. E. R.
    Silva, Es
    Henriques, B.
    BIODENTAL ENGINEERING IV, 2018, : 5 - 9
  • [7] Electrochemical evaluation of the hydrogen peroxide- and fluoride-induced corrosive property and its recovery on the titanium surface
    Furiya-Sato, Satoko
    Fukushima, Azusa
    Mayanagi, Gen
    Sasaki, Keiichi
    Takahashi, Nobuhiro
    JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (03) : 307 - 312
  • [8] Effect of Hydrogen Peroxide Dentifrice and Brushing on Surface Properties of Direct Esthetic Dental Composites
    Alrahlah, Ali
    Aldhafyan, Mohammed
    Khan, Aftab Ahmed
    Awad, Mohamed M.
    Vohra, Fahim
    Khan, Rawaiz
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2017, 7 (10) : 1051 - 1056
  • [9] Enamel Surface Changes After Exposure to Bleaching Gels Containing Carbamide Peroxide or Hydrogen Peroxide
    Cvikl, B.
    Lussi, A.
    Moritz, A.
    Flury, S.
    OPERATIVE DENTISTRY, 2016, 41 (01) : E39 - E47
  • [10] Decontamination of dental unit water systems with hydrogen peroxide
    Zanetti, F
    De Luca, G
    Tarlazzi, P
    Stampi, S
    LETTERS IN APPLIED MICROBIOLOGY, 2003, 37 (03) : 201 - 206