Comparative Evaluation of Bulk-Fill Composite Resins: Knoop Microhardness, Diametral Tensile Strength and Degree of Conversion

被引:1
作者
Strini, Bruna Scarcello [1 ]
Marques, Joyce Figueiredo de Lima [1 ,5 ]
Pereira, Renata [1 ]
Sobral-Souza, Danielle Ferreira [2 ]
Pecorari, Vanessa Gallego Arias [3 ]
Liporoni, Priscila Christiane Suzy [4 ]
Aguiar, Flavio Henrique Baggio [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Piracicaba, SP, Brazil
[2] Univ Fed Mato Grosso do Sul, Dent Sch, Campo Grande, MS, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Biostat, Piracicaba, SP, Brazil
[4] Univ Taubate, Dept Restorat Dent, Taubate, SP, Brazil
[5] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Ave Limeira 901, BR-13414903 Piracicaba, SP, Brazil
来源
CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY | 2022年 / 14卷
关键词
composite resins; Bulk-Fill; FTIR; hardness; tensile strength; INCREMENT THICKNESS; MARGINAL ADAPTATION; LIGHT ATTENUATION; SAMPLE THICKNESS; SHRINKAGE; RESTORATIONS; HARDNESS; ETHANOL;
D O I
10.2147/CCIDE.S376195
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Bulk-fill composite resins were developed to reduce time and facilitate the restorative procedure. However, considering their recent introduction on the market and the new formulations, their performance still requires evaluation. This study aimed to evaluate Knoop microhardness (KHN), diametral tensile strength (DTS) and degree of conversion (DC) of three Bulk-Fill composite resins and a conventional one. Materials and Methods: Sixty samples (n = 15; 8 mm empty set x 4 mm height) were confectioned using a mold. Filtek Bulk-Fill (FBF), Tetric N-Ceram Bulk-Fill (TNC) and SonicFill 2 (SF2) were placed in 4 mm increments, and Filtek Z350 (FZ350) was placed in 2 mm increments. The KHN of top and bottom surfaces were tested using Knoop Hardness tester at 10 gf/10s. The DTS was tested under compressive load at 1.0 mm/min. The DC was measured by Fourier Transform Infrared (FTIR) spectroscopy. Differences in DTS and DC were analyzed by ANOVA and Tukey post hoc test. For KHN, Kruskal-Wallis and Wilcoxon tests were performed at alpha = 0.05. Results: Top surfaces of all composite resins had higher KHN than bottom surfaces. At top and bottom surfaces, FZ350 showed higher KHN than TNC and SF2. The highest DTS was obtained by FBF, followed by FZ350 and SF2. The highest DC was obtained by SF2, the lowest one was obtained by FBF. Conclusion: From Bulk-Fill composite resins, FBF presented the best KHN and DTS results. The SF2 showed the best DC. Further studies are required to ensure whether these differences can negatively influence the behavior of in vivo restorations.
引用
收藏
页码:225 / 233
页数:9
相关论文
共 38 条
  • [1] Hardness and diametral tensile strength of a hybrid composite resin polymerized with different modes and immersed in ethanol or distilled water media
    Aguiar, FHB
    Braceiro, ATB
    Ambrosano, GMB
    Lovadino, JR
    [J]. DENTAL MATERIALS, 2005, 21 (12) : 1098 - 1103
  • [2] Influence of light curing and sample thickness on microhardness of a composite resin
    Aguiar, Flvio H. B.
    Andrade, Kelly R. M.
    Lima, Debora A. N. Leite
    Ambrosano, Glaucia M. B.
    Lovadino, Jose R.
    [J]. CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2009, 1 : 21 - 25
  • [3] Alger M.S.M., 1997, POLYM SCI DICT
  • [4] American Dental Association Certification Programs of the Council on Dental Materials Instruments and Equipment, 1977, American National Standards Institution/American Dental Association Specification 27 for direct filling resins
  • [5] Color Stability and Micro-Hardness of Bulk-Fill Composite Materials after Exposure to Common Beverages
    Bahbishi, Nora
    Mzain, Waad
    Badeeb, Bayan
    Nassar, Hani M.
    [J]. MATERIALS, 2020, 13 (03)
  • [6] Clinical Evaluation of a Low-shrinkage Composite in Posterior Restorations: One-Year Results
    Baracco, B.
    Perdigao, J.
    Cabrera, E.
    Giraldez, I.
    Ceballos, L.
    [J]. OPERATIVE DENTISTRY, 2012, 37 (02) : 117 - 129
  • [7] Benetti AR, 2011, AM J DENT, V24, P115
  • [8] Impact of the distance of light curing on the degree of conversion and microhardness of a composite resin
    Catelan, Anderson
    Napoleao De Araujo, Larissa Sgarbosa
    Martins Da Silveira, Bruna Cilene
    Kawano, Yoshio
    Bovi Ambrosano, Glaucia Maria
    Marchi, Giselle Maria
    Baggio Aguiar, Flavio Henrique
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2015, 73 (04) : 298 - 301
  • [9] Clinical performance and chemical-physical properties of bulk fill composites resin -a systematic review and meta-analysis
    Cidreira Boaro, Leticia Cristina
    Lopes, Diana Pereira
    Caetano de Souza, Andreia Santos
    Nakano, Ellea Lie
    Ayala Perez, Mirko Dennys
    Pfeifer, Carmem Silvia
    Goncalves, Flavia
    [J]. DENTAL MATERIALS, 2019, 35 (10) : E249 - E264
  • [10] Longevity of posterior composite restorations: Not only a matter of materials
    Demarco, Flavio F.
    Correa, Marcos B.
    Cenci, Maximiliano S.
    Moraes, Rafael R.
    Opdam, Niek J. M.