Cerebral embolic protection in thoracic endovascular aortic repair

被引:37
|
作者
Grover, Gagandeep [1 ]
Perera, Anisha H. [1 ]
Hamady, Mohamad [2 ]
Rudarakanchana, Nung [1 ]
Barras, Christen D. [3 ]
Singh, Abhinav [4 ]
Davies, Alun H. [1 ]
Gibbs, Richard [1 ]
机构
[1] Imperial Coll London, Dept Surg & Canc, Imperial Vasc Unit, London, England
[2] Imperial Hlthcare Coll NHS Trust, Dept Intervent Radiol, London, England
[3] Natl Hosp Neurol & Neurosurg, Lysholm Dept Neuroradiol, London, England
[4] Imperial Coll Hlthcare NHS Trust, Dept Neuroradiol, London, England
关键词
CEPD; DW-MRI; Embolization; HITS; TEVAR; STROKE; BRAIN; RISK; EMBOLIZATION; METAANALYSIS; MICROEMBOLI; INFARCTION; DEMENTIA; BYPASS;
D O I
10.1016/j.jvs.2017.11.098
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Stroke occurs in 3% to 8% and silent cerebral infarction in >60% of patients undergoing thoracic endovascular aortic repair (TEVAR). We investigated the utility of a filter cerebral embolic protection device (CEPD) to reduce diffusion-weighted magnetic resonance imaging (DW-MRI) detected cerebral injury and gaseous and solid embolization during TEVAR. Methods: Patients anatomically suitable underwent TEVAR with CEPD, together with intraoperative transcranial Doppler to detect gaseous and solid high-intensity transient signals (HITSs), pre- and postoperative DW-MRI, and clinical neurologic assessment <= 6 months after the procedure. Results: Ten patients (mean age, 68 years) underwent TEVAR with a CEPD. No strokes or device-related complications developed. The CEPD added a median of 7 minutes (interquartile range [IQR], 5-16 minutes) to the procedure, increased the fluoroscopy time by 3.3 minutes (IQR, 2.4-3.9 minutes), and increased the total procedural radiation by 2.2%. The dose area product for CEPD was 1824 mGy.cm(2) (IQR, 1235-3392 mGy.cm(2)). The average contrast volume used increased by 23 mL (IQR, 24-35 mL). New DW-MRI lesions, mostly in the hindbrain, were identified in seven of nine patients (78%). The median number was 1 (IQR, 1-3), with a median surface area of 6 mm(2) (IQR, 3-16 mm(2)). A total of 2835 HITSs were detected in seven patients: 91% gaseous and 9% solid. The maximum number of HITSs were detected during CEPD manipulation: 142 (IQR, 59-146; 95% gaseous and 5% solid). The maximum number of HITSs during TEVAR occurred during stent deployment: 82 (IQR, 73-142; 81% gas and 11% solid). Solid HITSs were associated with an increase in surface area of new DW-MRI lesions (r(s) = 0.928; P =.01). Increased gaseous HITSs were associated with new DW-MRI lesions (r(s) = 0.912; P =.01), which were smaller (< 3 mm; r = 0.88; P =.02). Embolic debris was captured in 95% of the filters. The median particle count was 937 (IQR, 146-1687), and the median surface area was 2.66 mm(2) (IQR, 0.08-9.18 mm(2)). Conclusions: The use of a CEPD with TEVAR appeared to be safe and feasible in this first pilot study and could serve as a useful adjunct to reduce cerebral injury. The significance of gaseous embolization and its role in cerebral injury in TEVAR warrants further investigation.
引用
收藏
页码:1656 / 1666
页数:11
相关论文
共 50 条
  • [41] Thoracic endovascular aortic repair of aortobronchial fistulas
    Ysa, A.
    Bustabad, M. R.
    ANGIOLOGIA, 2010, 62 (03): : 130 - 131
  • [42] Endovascular repair for thoracic aortic arch aneurysms
    Caronno, R.
    Piffaretti, G.
    Tozzi, M.
    Lomazzi, C.
    Cuffari, S.
    Sala, A.
    Castelli, P.
    INTERNATIONAL ANGIOLOGY, 2006, 25 (03) : 249 - 255
  • [43] Endovascular Repair of Blunt Thoracic Aortic Injuries
    Brinster, Derek R.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2009, 21 (04) : 393 - 398
  • [44] Thoracic endovascular aortic repair for ruptured pseudocoarctation
    Arakawa, Mamoru
    Yuri, Koichi
    Takeuchi, Taro
    Okamura, Homare
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (04): : E101 - E103
  • [45] Endovascular repair of traumatic thoracic aortic tears
    Mansour, M. Ashraf
    Kirk, Jeffrey S.
    Cuff, Robert F.
    Banegas, Shonda L.
    Ambrosi, Gavin M.
    Liao, Timothy H.
    Chambers, Christopher M.
    Wong, Peter Y.
    Heiser, John C.
    AMERICAN JOURNAL OF SURGERY, 2012, 203 (03): : 401 - 404
  • [46] Neurological Complications of Thoracic Endovascular Aortic Repair
    Ullery, Brant W.
    Wang, Grace J.
    Low, David
    Cheung, Albert T.
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 15 (04) : 123 - 140
  • [47] Endovascular repair in management of thoracic aortic aneurysms
    Bingol, Hakan
    Iyem, Hikmet
    Akay, Hakki Tankut
    Ustunsoz, Bahri
    Bolcal, Cengiz
    Ugurer, Sahin
    Sirin, Gokce
    Demirkilic, Ufuk
    Tatar, Harun
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (01): : 53 - 59
  • [48] Thoracic Endovascular Aortic Repair in Octogenarians and Nonagenarians
    Akhmerov, Akbarshakh
    Shah, Aamir S.
    Gupta, Navyash
    Tulloch, Allan W.
    Gewertz, Bruce
    Azizzadeh, Ali
    ANNALS OF VASCULAR SURGERY, 2020, 68 : 299 - 304
  • [49] Thoracic endovascular aortic repair of aortobronchial fistulas
    Riesenman, Paul J.
    Brooks, James D.
    Farber, Mark A.
    JOURNAL OF VASCULAR SURGERY, 2009, 50 (05) : 992 - 998
  • [50] Explantation of infected thoracic endovascular aortic repair
    Fan, Emily Y.
    Judelson, Dejah R.
    Schanzer, Andres
    JOURNAL OF VASCULAR SURGERY CASES AND INNOVATIVE TECHNIQUES, 2018, 4 (04): : 307 - 310