Cerebral embolic protection in thoracic endovascular aortic repair

被引:39
作者
Grover, Gagandeep [1 ]
Perera, Anisha H. [1 ]
Hamady, Mohamad [2 ]
Rudarakanchana, Nung [1 ]
Barras, Christen D. [3 ]
Singh, Abhinav [4 ]
Davies, Alun H. [1 ]
Gibbs, Richard [1 ]
机构
[1] Imperial Coll London, Dept Surg & Canc, Imperial Vasc Unit, London, England
[2] Imperial Hlthcare Coll NHS Trust, Dept Intervent Radiol, London, England
[3] Natl Hosp Neurol & Neurosurg, Lysholm Dept Neuroradiol, London, England
[4] Imperial Coll Hlthcare NHS Trust, Dept Neuroradiol, London, England
关键词
CEPD; DW-MRI; Embolization; HITS; TEVAR; STROKE; BRAIN; RISK; EMBOLIZATION; METAANALYSIS; MICROEMBOLI; INFARCTION; DEMENTIA; BYPASS;
D O I
10.1016/j.jvs.2017.11.098
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Stroke occurs in 3% to 8% and silent cerebral infarction in >60% of patients undergoing thoracic endovascular aortic repair (TEVAR). We investigated the utility of a filter cerebral embolic protection device (CEPD) to reduce diffusion-weighted magnetic resonance imaging (DW-MRI) detected cerebral injury and gaseous and solid embolization during TEVAR. Methods: Patients anatomically suitable underwent TEVAR with CEPD, together with intraoperative transcranial Doppler to detect gaseous and solid high-intensity transient signals (HITSs), pre- and postoperative DW-MRI, and clinical neurologic assessment <= 6 months after the procedure. Results: Ten patients (mean age, 68 years) underwent TEVAR with a CEPD. No strokes or device-related complications developed. The CEPD added a median of 7 minutes (interquartile range [IQR], 5-16 minutes) to the procedure, increased the fluoroscopy time by 3.3 minutes (IQR, 2.4-3.9 minutes), and increased the total procedural radiation by 2.2%. The dose area product for CEPD was 1824 mGy.cm(2) (IQR, 1235-3392 mGy.cm(2)). The average contrast volume used increased by 23 mL (IQR, 24-35 mL). New DW-MRI lesions, mostly in the hindbrain, were identified in seven of nine patients (78%). The median number was 1 (IQR, 1-3), with a median surface area of 6 mm(2) (IQR, 3-16 mm(2)). A total of 2835 HITSs were detected in seven patients: 91% gaseous and 9% solid. The maximum number of HITSs were detected during CEPD manipulation: 142 (IQR, 59-146; 95% gaseous and 5% solid). The maximum number of HITSs during TEVAR occurred during stent deployment: 82 (IQR, 73-142; 81% gas and 11% solid). Solid HITSs were associated with an increase in surface area of new DW-MRI lesions (r(s) = 0.928; P =.01). Increased gaseous HITSs were associated with new DW-MRI lesions (r(s) = 0.912; P =.01), which were smaller (< 3 mm; r = 0.88; P =.02). Embolic debris was captured in 95% of the filters. The median particle count was 937 (IQR, 146-1687), and the median surface area was 2.66 mm(2) (IQR, 0.08-9.18 mm(2)). Conclusions: The use of a CEPD with TEVAR appeared to be safe and feasible in this first pilot study and could serve as a useful adjunct to reduce cerebral injury. The significance of gaseous embolization and its role in cerebral injury in TEVAR warrants further investigation.
引用
收藏
页码:1656 / 1666
页数:11
相关论文
共 28 条
[1]   Transcranial Doppler findings during thoracic endovascular aortic repair [J].
Bismuth, Jean ;
Garami, Zsolt ;
Anaya-Ayala, Javier E. ;
Naoum, Joseph J. ;
El Sayed, Hosam F. ;
Peden, Eric K. ;
Lumsden, Alan B. ;
Davies, Mark G. .
JOURNAL OF VASCULAR SURGERY, 2011, 54 (02) :364-369
[2]   Endovascular Aortic Repair Versus Open Surgical Repair for Descending Thoracic Aortic Disease A Systematic Review and Meta-Analysis of Comparative Studies [J].
Cheng, Davy ;
Martin, Janet ;
Shennib, Hani ;
Dunning, Joel ;
Muneretto, Claudio ;
Schueler, Stephan ;
Von Segesser, Ludwig ;
Sergeant, Paul ;
Turina, Marko .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10) :986-1001
[3]   MR SIGNAL ABNORMALITIES AT 1.5-T IN ALZHEIMER DEMENTIA AND NORMAL AGING [J].
FAZEKAS, F ;
CHAWLUK, JB ;
ALAVI, A ;
HURTIG, HI ;
ZIMMERMAN, RA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (02) :351-356
[4]   Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: a randomized controlled trial [J].
Gerriets, Tibo ;
Schwarz, Niko ;
Sammer, Gebhard ;
Baehr, Jeanette ;
Stolz, Erwin ;
Kaps, Manfred ;
Kloevekorn, Wolf-Peter ;
Bachmann, Georg ;
Schoenburg, Markus .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :360-368
[5]   Neurological Outcomes With Embolic Protection Devices in Patients Undergoing Transcatheter Aortic Valve Replacement A Systematic Review and Meta-Analysis of Randomized Controlled Trials [J].
Giustino, Gennaro ;
Mehran, Roxana ;
Veltkamp, Roland ;
Faggioni, Michela ;
Baber, Usman ;
Dangas, George D. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (20) :2124-2133
[6]   Risk factors for perioperative stroke after thoracic endovascular aortic repair [J].
Gutsche, Jacob T. ;
Cheung, Albert T. ;
McGarvey, Michael L. ;
Moser, William G. ;
Szeto, Wilson ;
Carpenter, Jeffrey P. ;
Fairman, Ronald M. ;
Pochettino, Alberto ;
Bavaria, Joseph E. .
ANNALS OF THORACIC SURGERY, 2007, 84 (04) :1195-1200
[7]   Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis The CLEAN-TAVI Randomized Clinical Trial [J].
Haussig, Stephan ;
Mangner, Norman ;
Dwyer, Michael G. ;
Lehmkuhl, Lukas ;
Luecke, Christian ;
Woitek, Felix ;
Holzhey, David M. ;
Mohr, Friedrich W. ;
Gutberlet, Matthias ;
Zivadinov, Robert ;
Schuler, Gerhard ;
Linke, Axel .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (06) :592-601
[8]   Air bubbles are released by thoracic endograft deployment: An in vitro experimental study [J].
Inci, Kamuran ;
Koutouzi, Giasemi ;
Chernoray, Valery ;
Jeppsson, Anders ;
Nilsson, Hakan ;
Falkenberg, Marten .
SAGE OPEN MEDICINE, 2016, 4
[9]   Silent Cerebral Ischemia After Thoracic Endovascular Aortic Repair: A Neuroimaging Study [J].
Kahlert, Philipp ;
Eggebrecht, Holger ;
Janosi, Rolf A. ;
Hildebrandt, Heike A. ;
Plicht, Bjoern ;
Tsagakis, Konstantinos ;
Moenninghoff, Christoph ;
Nensa, Felix ;
Mummel, Petra ;
Heusch, Gerd ;
Jakob, Heinz G. ;
Forsting, Michael ;
Erbel, Raimund ;
Schlamann, Marc .
ANNALS OF THORACIC SURGERY, 2014, 98 (01) :53-58
[10]   Protection Against Cerebral Embolism During Transcatheter Aortic Valve Replacement [J].
Kapadia, Samir R. ;
Kodali, Susheel ;
Makkar, Raj ;
Mehran, Roxana ;
Lazar, Ronald M. ;
Zivadinov, Robert ;
Dwyer, Michael G. ;
Jilaihawi, Hasan ;
Virmani, Renu ;
Anwaruddin, Saif ;
Thourani, Vinod H. ;
Nazif, Tamim ;
Mangner, Norman ;
Woitek, Felix ;
Krishnaswamy, Amar ;
Mick, Stephanie ;
Chakravarty, Tarun ;
Nakamura, Mamoo ;
McCabe, James M. ;
Satler, Lowell ;
Zajarias, Alan ;
Szeto, Wilson Y. ;
Svensson, Lars ;
Alu, Maria C. ;
White, Roseann M. ;
Kraemer, Carlye ;
Parhizgar, Azin ;
Leon, Martin B. ;
Linke, Axel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (04) :367-377