Achieving high absolute accuracy for group-delay measurements using the modulation phase-shift technique

被引:14
作者
Dennis, T [1 ]
Williams, PA [1 ]
机构
[1] Natl Inst Stand & Technol, Boulder, CO 80305 USA
关键词
calibration; microwave photonics; optical communication; optical components; optical propagation in dispersive media; optical variables measurements; reference material; uncertainty;
D O I
10.1109/JLT.2005.856199
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have developed a modulation phase-shift (MPS) system for measuring relative group delay (RGD) in optical components with high absolute accuracy and simultaneously high temporal and wavelength resolution. Our 200-MHz system has a 3.2-pm wavelength resolution and has demonstrated a group-delay resolution of 0.072 ps for repeated measurements of an artifact based on a hydrogen-cyanide gas cell. The expanded uncertainty (2 sigma) is +/- 0.46 ps for a single spectral measurement (similar to 3.4-pm steps) of a narrow 20-ps group-delay feature of the artifact. To our knowledge, this is the first time that the sources of measurement uncertainty for this technique have been described and quantified. A method for predicting the group delay of the gas-cell artifact from measured absorption spectra is described, and an uncertainty analysis for the prediction method is also presented. The implementation required to achieve results of the highest accuracy for both measurements and predictions is discussed.
引用
收藏
页码:3748 / 3754
页数:7
相关论文
共 17 条
  • [11] Accurate measurements of the zero-dispersion wavelength in optical fibers
    Mechels, SE
    Schlager, JB
    Franzen, DL
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1997, 102 (03) : 333 - 347
  • [12] MOTAMEDI A, 2001, P OPT FIB COMM OFC A
  • [13] Limitations of phase-shift method in measuring dense group delay ripple of fiber Bragg gratings
    Niemi, T
    Uusimaa, M
    Ludvigsen, H
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2001, 13 (12) : 1334 - 1336
  • [14] Reitz John., 1980, Foundations of Electromagnetic Theory, V3rd ed
  • [15] CALIBRATION LINES OF HCN IN THE 1.5-MU-M REGION
    SASADA, H
    YAMADA, K
    [J]. APPLIED OPTICS, 1990, 29 (24): : 3535 - 3547
  • [16] Pressure-induced shift and broadening of 1510-1540-nm acetylene wavelength calibration lines
    Swann, WC
    Gilbert, SL
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2000, 17 (07) : 1263 - 1270
  • [17] Taylor CE Kuyatt B.N., 1994, GUIDELINES EVALUATIN, DOI DOI 10.6028/NIST.TN.1297