Towards fluorescence anisotropy detection for real-time PCR assays

被引:0
作者
Crane, B [1 ]
Sudo, H [1 ]
Thilly, WG [1 ]
Hunter, IW [1 ]
机构
[1] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
来源
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH | 2003年 / 25卷
关键词
fluorescence anisotropy; real-time PCR; fluorescence polarization;
D O I
10.1109/IEMBS.2003.1280787
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Real-time PCR methods play a valuable role in the characterization of mutations as well as gene expression studies. Existing techniques such as TaqMAN(TM) and Molecular Beacons(TM) employ specially designed oligonucleotides whose fluorescent resonance energy transfer (FRET) is affected by the reaction progression. Such methods have proven repeatable and accurate, however the challenges in design and cost of these reagents are limiting for high throughput applications. Other less expensive techniques, such as the use of intercalating probes, lack the specificity to allow simultaneous detection of multiple alleles. To overcome these limitations, we are developing an alternative real-time PCR detection technique based on fluorescence anisotropy (FA) that relies only on fluorescently labeled forward primers. Previous work on FA and PCR has highlighted several barriers to their combination. Here we analyze these challenges and study the specifications for instrumentation to overcome them. We report the construction of an apparatus testing these specifications in which very low noise FA measurements have been made throughout the progress of the PCR procedure. This work demonstrates the feasibility of FA detection for reduced cost analysis of real-time PCR assays for high throughput applications.
引用
收藏
页码:3060 / 3063
页数:4
相关论文
共 15 条
[11]   Simultaneous strand displacement amplification and fluorescence polarization detection of Chlamydia trachomatis DNA [J].
Spears, PA ;
Linn, CP ;
Woodard, DL ;
Walker, GT .
ANALYTICAL BIOCHEMISTRY, 1997, 247 (01) :130-137
[12]   DNA detection by strand displacement amplification and fluorescence polarization with signal enhancement using a DNA binding protein [J].
Walker, GT ;
Linn, CP ;
Nadeau, JG .
NUCLEIC ACIDS RESEARCH, 1996, 24 (02) :348-353
[13]  
WALKER GT, 1997, FLUORESCENCE POLARIZ
[14]   Kinetic FP-TDI assay for SNP allele frequency determination [J].
Xiao, M ;
Latif, SM ;
Kwok, PY .
BIOTECHNIQUES, 2003, 34 (01) :190-+
[15]   Quantitative analysis of polymerase chain reaction using anisotropy ratio and relative hydrodynamic volume of fluorescence polarization method [J].
Ye, BC ;
Ikebukuro, K ;
Karube, I .
NUCLEIC ACIDS RESEARCH, 1998, 26 (15) :3614-3615