Echocardiographic Changes in Patients Implanted With a Fully Magnetically Levitated Left Ventricular Assist Device (Heartmate 3)

被引:12
|
作者
Uriel, Nir [1 ]
Medvedofsky, Diego [1 ]
Imamura, Teruhiko [1 ]
Maly, Jiri [3 ]
Kruse, Eric [1 ]
Ivak, Peter [2 ]
Sood, Poornima [4 ]
Lang, Roberto M. [1 ]
Maffessanti, Francesco [5 ]
Berliner, Dominik [2 ]
Bauersachs, Johann [2 ]
Haverich, Axel [2 ]
Zelizko, Michael [3 ]
Netuka, Ivan [3 ]
Schmitto, Jan D. [2 ]
机构
[1] Univ Chicago, Med Ctr, Dept Med, Chicago, IL 60637 USA
[2] Hannover Med Sch, Dept Cardiothorac Transplantat & Vasc Surg, Hannover, Germany
[3] Inst Clin & Expt Med, Dept Cardiovasc Surg, Prague, Czech Republic
[4] Abbott, Minneapolis, MN USA
[5] Univ Svizzera Italiana, Ctr Computat Med Cardiol, Inst Computat Sci, Lugano, Switzerland
关键词
HVAD; Heartmate; 3; echocardiography; conicity; sphericity; ramp test; CONTINUOUS-FLOW; SPEED OPTIMIZATION; RAMP; SUPPORT; THROMBOSIS; FAILURE; IMPACT;
D O I
10.1016/j.cardfail.2018.11.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The Heartmate 3 (HM3) is a Conformitee Europeenne mark approved left ventricular (LV) assist device (LVAD) with fully magnetically levitated rotor and features consisting of a wide range operational speeds, wide flow paths, and artificial pulse. We performed a hemodynamic-echocardiographic speed optimization evaluation in HM3-implanted patients to achieve optimal LV- and right ventricular (RV) shape. Methods and Results: Sixteen HM3 patients underwent pump speed ramp tests with right heart catheterization. Three-dimensional echocardiographic (3DE) LV and RV datasets (Philips) were acquired, and volumetric (Tomtec) and shape (custom software) analyses were performed (LV: sphericity, conicity; RV: septal and free-wall curvatures). Data were recorded at up to 13 speed settings. Speed changes were in 100-rpm steps, starting at 4600 rpm and ramping up to 6200 rpm. 3DE was feasible in 50% of the patients. Mean original speed was 5306 +/- 148 rpm. LV end-diastolic (ED) diameter (-0.15 +/- 0.09 cm/100 rpm) and volumes (ED: 269 +/- 109 mL to 175 +/- 90 mL; end-systolic [ES]: 234 +/- 111 mL to 146 +/- 81 mL) progressively decreased as the shape became less spherical and more conical; RV volumes initially remained stable, but at higher speeds increased (ED: from 148 +/- 64 mL to 181 +/- 92 mL; ES: 113 +/- 63 mL to 130 +/- 69 mL). On average, the RV septum became less convex (bulging toward the LV) at the highest speeds. Conclusions: LV and RV shape changes were noted in HM3-supported patients. Although a LV volumetric decrease and shape improvement was consistently noted, RV volumes grew in response to increase in speed above a certain point. A next concern would be whether understanding of morphologic and function changes in LV and RV during LVAD speed change assessed with the use of 3DE helps to optimize LVAD speed settings and improve clinical outcomes.
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [1] Clinical hemodynamic evaluation of patients implanted with a fully magnetically levitated left ventricular assist device (HeartMate 3)
    Uriel, Nir
    Adatya, Sirtaz
    Maly, Jiri
    Kruse, Eric
    Rodgers, Daniel
    Heatley, Gerald
    Herman, Ales
    Sood, Poornima
    Berliner, Dominik
    Bauersachs, Johann
    Haverich, Axel.
    Zelizko, Michael
    Schmitto, Jan D.
    Netuka, Ivan
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (01): : 28 - 35
  • [2] Sound analysis of the magnetically levitated left ventricular assist device HeartMate 3™
    Sundbom, Per
    Roth, Michael
    Granfeldt, Hans
    Karlsson, Daniel M.
    Ahn, Henrik
    Gustafsson, Fredrik
    Dellgren, Goran
    Hubbert, Laila
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2019, 42 (12): : 717 - 724
  • [3] HeartMate 3 fully magnetically levitated left ventricular assist device for advanced heart failure - initial Serbian experience
    Nestorovic, Emilija
    Terzic, Dusko
    Putnik, Svetozar
    Ristic, Arsen
    Ristic, Miljko
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2018, 146 (9-10) : 584 - 587
  • [4] A Fully Magnetically Levitated Left Ventricular Assist Device - Final Report
    Mehra, M. R.
    Uriel, N.
    Naka, Y.
    Cleveland, J. C., Jr.
    Yuzefpolskaya, M.
    Salerno, C. T.
    Walsh, M. N.
    Milano, C. A.
    Patel, C. B.
    Hutchins, S. W.
    Ransom, J.
    Ewald, G. A.
    Itoh, A.
    Raval, N. Y.
    Silvestry, S. C.
    Cogswell, R.
    John, R.
    Bhimaraj, A.
    Bruckner, B. A.
    Lowes, B. D.
    Um, J. Y.
    Jeevanandam, V.
    Sayer, G.
    Mangi, A. A.
    Molina, E. J.
    Sheikh, F.
    Aaronson, K.
    Pagani, F. D.
    Cotts, W. G.
    Tatooles, A. J.
    Babu, A.
    Chomsky, D.
    Katz, J. N.
    Tessmann, P. B.
    Dean, D.
    Krishnamoorthy, A.
    Chuang, J.
    Topuria, I.
    Sood, P.
    Goldstein, D. J.
    NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (17): : 1618 - 1627
  • [5] Magnetically Levitated Left Ventricular Assist Device
    Dalzell, Jonathan R.
    Connolly, Eugene C.
    Cannon, Jane A.
    NEW ENGLAND JOURNAL OF MEDICINE, 2019, 381 (05): : 489 - 490
  • [6] The momentum of HeartMate 3: a novel active magnetically levitated centrifugal left ventricular assist device (LVAD)
    Chatterjee, Anamika
    Feldmann, Christina
    Hanke, Jasmin S.
    Ricklefs, Marcel
    Shrestha, Malakh
    Dogan, Guenes
    Haverich, Axel
    Schmitto, Jan D.
    JOURNAL OF THORACIC DISEASE, 2018, 10 : S1790 - S1793
  • [7] First implantation in man of a new magnetically levitated left ventricular assist device (HeartMate III)
    Schmitto, Jan D.
    Hanke, Jasmin S.
    Rojas, Sebastian V.
    Avsar, Murat
    Haverich, Axel
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (06): : 858 - 860
  • [8] HeartMate 3, Fully Magnetically Levitated Left Ventricular Assist Device for the Treatment of Advanced Heart Failure -Results from the CE Mark Trial
    Netuka, Ivan
    Pya, Yuriy
    Zimpfer, Daniel
    Krabatsch, Thomas
    Garbade, Jens
    Rao, Vivek
    Morshuis, Michiel
    Marasco, Silvana
    Beyersdorf, Friedhelm
    Sood, Poornima
    Damme, Laura
    Schmitto, Jan D.
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (11) : 936 - 936
  • [9] Magnetically Levitated Left Ventricular Assist Device Reply
    Mehra, Mandeep R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2019, 381 (05): : 490 - 490
  • [10] An Examination of Bleeding and Thromboembolic Complications during the First Year of Support with the HeartMate 3 Fully Magnetically-Levitated Left Ventricular Assist Device
    Rao, V.
    Netuka, I.
    Schmitto, J.
    Pya, Y.
    Heatley, J.
    Damme, L.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S40 - S40