Effect of bandage thickness on interface pressure applied by compression bandages

被引:31
作者
Al Khaburi, Jawad [1 ]
Dehghani-Sanij, Abbas A. [1 ]
Nelson, E. Andrea [2 ]
Hutchinson, Jerry [3 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Sch Healthcare, Leeds LS2 9JT, W Yorkshire, England
[3] ConvaTec Ltd, Deeside, Clwyd, Wales
关键词
Leg ulcer; Laplace; Compression bandaging; Interface pressure; CHRONIC VENOUS INSUFFICIENCY; STOCKING; MODEL; LEG;
D O I
10.1016/j.medengphy.2011.07.028
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Medical compression bandages are widely used in the treatment of chronic venous disorder. In order to design effective compression bandages, researchers have attempted to describe the interface pressure applied by these bandages using mathematical models. This paper reports on the work carried out to derive the mathematical model used to describe the interface pressure applied by single-layer bandage using two different approaches. The first assumes that the bandage thickness is negligible, whereas the second model includes the bandage thickness. The estimated pressures using the two formulae are then compared, simulated over a 3D representation of a real leg and validated experimentally. Both theoretical and experimental results have shown that taking bandage thickness into consideration while estimating the pressures applied by a medical compression bandage will result in more accurate estimation. However, the additional accuracy is clinically insignificant. (C) 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:378 / 385
页数:8
相关论文
共 23 条
[1]   The Law of Laplace and its relevance to contemporary medicine and rehabilitation [J].
Basford, JR .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (08) :1165-1170
[2]   The epidemiology of chronic venous insufficiency and varicose veins [J].
Beebe-Dimmer, JL ;
Pfeifer, JR ;
Engle, JS ;
Schottenfeld, D .
ANNALS OF EPIDEMIOLOGY, 2005, 15 (03) :175-184
[3]  
Bolton W, 1996, MEASUREMENT INSTRUME, P412
[4]  
DEBRUYNE P, 1976, MED BIOL ENG, V14, P94
[5]   Evaluation of a sensor for low interface pressure applications [J].
Ferguson-Pell, M ;
Hagisawa, S ;
Bain, D .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (09) :657-663
[6]   Experimental assessment and analytical 2D predictions of the stocking pressures induced on a model leg by medical compressive stockings [J].
Gaied, I. ;
Drapier, S. ;
Lun, B. .
JOURNAL OF BIOMECHANICS, 2006, 39 (16) :3017-3025
[7]  
Ghosh S, 2008, J Tissue Viability, V17, P82, DOI 10.1016/j.jtv.2007.09.013
[8]  
Hearn EJ, 1997, MECH MATER, P450
[9]   Model to predict interfacial pressures in multilayer elastic fabric tubes [J].
Hui, CL ;
Ng, SF .
TEXTILE RESEARCH JOURNAL, 2001, 71 (08) :683-687
[10]   Evaluation of thin, flexible sensors for time-resolved grip force measurement [J].
Komi, E. R. ;
Roberts, J. R. ;
Rothberg, S. J. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2007, 221 (12) :1687-1699