Quantification of the accuracy of MRI generated 3D models of long bones compared to CT generated 3D models

被引:94
|
作者
Rathnayaka, Kanchana [1 ]
Momot, Konstantin I. [2 ]
Noser, Hansrudi [3 ]
Volp, Andrew [4 ]
Schuetz, Michael A. [1 ,4 ]
Sahama, Tony [2 ]
Schmutz, Beat [1 ]
机构
[1] Inst Hlth & Biomed Innovat, Kelvin Grove, Qld 4059, Australia
[2] Queensland Univ Technol, Brisbane, Qld 4000, Australia
[3] AO Res Inst Davos, CH-7270 Davos, Switzerland
[4] Princess Alexandra Hosp, Brisbane, Qld 4102, Australia
关键词
MRI; CT; 3D models; Femur; DISTAL MEDIAL TIBIA; FIT ASSESSMENT; HEAD MOTION; REGISTRATION; RELAXATION; ANISOTROPY; CARTILAGE; CHINESE;
D O I
10.1016/j.medengphy.2011.07.027
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Orthopaedic fracture fixation implants are increasingly being designed using accurate 3D models of long bones based on computer tomography (Cl'). Unlike CT, magnetic resonance imaging (MRI) does not involve ionising radiation and is therefore a desirable alternative to CT. This study aims to quantify the accuracy of MRI-based 3D models compared to CT-based 3D models of long bones. The femora of five intact cadaver ovine limbs were scanned using a 1.5T MRI and a CT scanner. Image segmentation of CT and MRI data was performed using a multi-threshold segmentation method. Reference models were generated by digitising the bone surfaces free of soft tissue with a mechanical contact scanner. The MRI- and CT-derived models were validated against the reference models. The results demonstrated that the CT-based models contained an average error of 0.15 mm while the MRI-based models contained an average error of 0.23 mm. Statistical validation shows that there are no significant differences between 3D models based on CT and MRI data. These results indicate that the geometric accuracy of MRI based 3D models was comparable to that of CT-based models and therefore MRI is a potential alternative to CT for generation of 3D models with high geometric accuracy. (C) 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:357 / 363
页数:7
相关论文
共 50 条
  • [1] Accuracy of cardiac magnetic resonance generated 3D models of the aortic annulus compared to cardiovascular computed tomography generated 3D models
    Gatti, Marco
    Cosentino, Aurelio
    Cura Stura, Erik
    Bergamasco, Laura
    Garabello, Domenica
    Pennisi, Giovanni
    Puppo, Mattia
    Salizzoni, Stefano
    Veglia, Simona
    Davini, Ottavio
    Rinaldi, Mauro
    Fonio, Paolo
    Faletti, Riccardo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (10): : 2007 - 2015
  • [2] Accuracy of cardiac magnetic resonance generated 3D models of the aortic annulus compared to cardiovascular computed tomography generated 3D models
    Marco Gatti
    Aurelio Cosentino
    Erik Cura Stura
    Laura Bergamasco
    Domenica Garabello
    Giovanni Pennisi
    Mattia Puppo
    Stefano Salizzoni
    Simona Veglia
    Ottavio Davini
    Mauro Rinaldi
    Paolo Fonio
    Riccardo Faletti
    The International Journal of Cardiovascular Imaging, 2020, 36 : 2007 - 2015
  • [3] QUALITY OF 3D MODELS GENERATED BY SFM TECHNOLOGY
    Marcis, M.
    SLOVAK JOURNAL OF CIVIL ENGINEERING, 2013, 21 (04) : 13 - 24
  • [4] The Accuracy of 3D Printed Carpal Bones Generated from Cadaveric Specimens
    Lebowitz, Cory
    Massaglia, Joseph
    Hoffman, Christopher
    Lucenti, Ludovico
    Dheer, Sachin
    Rivlin, Michael
    Beredjiklian, Pedro K.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2021, 9 (04): : 432 - 438
  • [5] ACCURACY ASSESSMENT OF 3D MODELS GENERATED FROM GOOGLE STREET VIEW IMAGERY
    Bruno, N.
    Roncella, R.
    8TH INTERNATIONAL WORKSHOP 3D-ARCH: 3D VIRTUAL RECONSTRUCTION AND VISUALIZATION OF COMPLEX ARCHITECTURES, 2019, 42-2 (W9): : 181 - 188
  • [6] TESTING THE REPRODUCIBILITY OF 3D MODELS OF LONG BONES: MDCT VERSUS 3D SURFACE SCANNING
    Campana, Lorenzo
    Fahrni, Stella
    Grabherr, Silke
    Uldin, Tanya
    FORENSIC SCIENCE INTERNATIONAL, 2017, 277 : 3 - 4
  • [7] Quantification of the accuracy of additive manufactured (3D printed) medical models
    Manmadhachary, A.
    Siva Rama Krishana, L.
    Saxena, Kuldeep K.
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2022,
  • [8] Increased Accuracy in Templating for Total Knee Arthroplasty Using 3D Models Generated from Radiographs
    Klag, Elizabeth A.
    Lizzio, Vincent A.
    Charters, Michael A.
    Ayoola, Ayooluwa S.
    Wesemann, Luke
    Banka, Trevor R.
    North, W. Trevor
    JOURNAL OF KNEE SURGERY, 2023, 36 (08) : 837 - 842
  • [9] 3D printing anatomical models of head bones
    Bartikian, M.
    Ferreira, A.
    Goncalves-Ferreira, A.
    Neto, L. L.
    SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (10) : 1205 - 1209
  • [10] 3D printing anatomical models of head bones
    M. Bartikian
    A. Ferreira
    A. Gonçalves-Ferreira
    L. L. Neto
    Surgical and Radiologic Anatomy, 2019, 41 : 1205 - 1209