Standardized LC-MS/MS based steroid hormone profile-analysis

被引:161
作者
Koal, Therese [1 ]
Schmiederer, Diane [1 ]
Hai Pham-Tuan [1 ]
Roehring, Cornelia [1 ]
Rauh, Manfred [2 ]
机构
[1] BIOCRATES Life Sci AG, A-6020 Innsbruck, Austria
[2] Univ Klinikum Erlangen, Kinder & Jugendklin, D-91054 Erlangen, Germany
关键词
Steroid hormones; High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS); Endocrinology; Kit; Standardization; Metyrapone; TANDEM MASS-SPECTROMETRY; SERUM TESTOSTERONE; CUSHINGS-SYNDROME; CHALLENGES; ANDROSTENEDIONE; ENDOCRINOLOGY; CORTISOL; THERAPY; ASSAYS; WOMEN;
D O I
10.1016/j.jsbmb.2011.12.001
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In order to overcome many limitations of immunoassays, high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has the potential to find its place in the clinical laboratory medicine for quantification of steroid hormones. A prerequisite for the application of a new analytical procedure in clinical diagnostics is standardization to minimize analytical intra- and interlaboratory variability and inaccuracy. We evaluate a newly standardized HPLC-MS/MS assay in kit-format, developed for routine determination of 16 steroid hormones in human serum samples. Fifteen metabolites can be measured quantitatively, which include aldosterone, androstenedione, androsterone, corticosterone, cortisol, cortisone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulfate (DHEAS), 17 beta-estradiol (E2), estrone (E1), etiocholanolone, 17 alpha-hydroxyprogesterone (17OHP), progesterone, and testosterone. 11-Deoxycorticosterone is the only compound rated as semi-quantitative in this kit. The sample preparation is performed by solid phase extraction (SPE) on a 96-well plate. The standardized assay has been validated for human serum in terms of lower and upper limit of quantification (LLOQ0.01-32 ng/mL, ULOQ 5-8000 ng/mL), linear correlation coefficient of calibration (R-2 > 0.9966). intra- and inter-day precision (intra-day 1.1-8.8%, inter-day 5.2-14.8% and 8.2-18.6% for 11-deoxycorticosterone), accuracy (intra-day 88.3-115.5% and 109.3-128.2% for 11-deoxycorticosterone, inter-day 91.4-117.2% and 102.3-137.1% for 11-deoxycorticosterone), analytical total error (3.6-17.8%), proficiency test accuracy (85.4-113.4%), recovery (68-99%), and metabolite stability (freeze/thaw stability 95.5-108.1%, short term stability 86.9-107.2%). Inter-assay comparison with a routine reference HPLC-MS/MS assay and seven immunoassays demonstrates the outstanding high performance of this HPLC-MS/MS based kit by improvements in accuracy for progesterone, androstenedione, and 17OHP. Finally, results of two metyrapone tests demonstrate the potential of the standardized HPLC-MS/MS assay for the analysis of a comprehensive steroid hormone profile in clinical diagnostics. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 36 条
[1]  
Alexandraki KI, 2010, FRONT HORM RES, V38, P165, DOI 10.1159/000318507
[2]  
[Anonymous], 2011, DESIRABLE SPECIFICAT
[3]  
[Anonymous], 2001, Guidance for industry - bioanalytical method validation
[4]   Preclinical challenges in steroid analysis of human samples [J].
Ceglarek, Uta ;
Werner, Maria ;
Kortz, Linda ;
Koerner, Antje ;
Kiess, Wieland ;
Thiery, Joachim ;
Kratzsch, Juergen .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (3-5) :505-512
[5]   Steroid profiling and analytics: Going towards sterome [J].
Ceglarek, Uta ;
Shackleton, Cedric ;
Stanczyk, Frank Z. ;
Adamski, Jerzy .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (3-5) :479-480
[6]   CUSHINGS-SYNDROME - REVIEW OF DIAGNOSTIC-TESTS [J].
CRAPO, L .
METABOLISM-CLINICAL AND EXPERIMENTAL, 1979, 28 (09) :955-977
[7]   Serum steroid profiling by isotopic dilution-liquid chromatography-mass spectrometry: Comparison with current immunoassays and reference intervals in healthy adults [J].
Fanelli, Flaminia ;
Belluomo, Ilaria ;
Di Lallo, Valentina D. ;
Cuomo, Gaia ;
De Iasio, Rosaria ;
Baccini, Margherita ;
Casadio, Elena ;
Casetta, Bruno ;
Vicennati, Valentina ;
Gambineri, Alessandra ;
Grossi, Gabriele ;
Pasquali, Renato ;
Pagotto, Uberto .
STEROIDS, 2011, 76 (03) :244-253
[8]   Development of a liquid chromatography-tandem mass spectrometry method for the determination of 23 endogenous steroids in small quantities of primate urine [J].
Hauser, Barbara ;
Deschner, Tobias ;
Boesch, Christophe .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2) :100-112
[9]   Steroid hormones: relevance and measurement in the clinical laboratory [J].
Holst, JP ;
Soldin, OP ;
Guo, TD ;
Soldin, SJ .
CLINICS IN LABORATORY MEDICINE, 2004, 24 (01) :105-+
[10]   Glucocorticoid replacement in pituitary surgery: Guidelines for perioperative assessment and management [J].
Inder, WJ ;
Hunt, PJ .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2002, 87 (06) :2745-2750