In vitro hemodynamic investigation of the embryonic aortic arch at late gestation

被引:20
作者
Pekkan, Kerem [1 ]
Dasi, Lakshmi P. [2 ]
Nourparvar, Paymon [2 ]
Yerneni, Srinivasu [2 ]
Tobita, Kimimasa [3 ,4 ,5 ]
Fogel, Mark A. [3 ,5 ]
Keller, Bradley [3 ,4 ,5 ]
Yoganathan, Ajit [2 ]
机构
[1] Carnegie Mellon Univ, Dept Biomed & Mech Engn, Pittsburgh, PA 15213 USA
[2] Georgia Inst Technol, Sch Biomed Engn, Atlanta, GA 30332 USA
[3] Childrens Hosp Pittsburgh, Dept Pediat, Pittsburgh, PA USA
[4] Childrens Hosp Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[5] Childrens Hosp Pittsburgh, Dept Cardiol, Pittsburgh, PA USA
关键词
cardiac development; hemodynamics; CFD; cardiovascular fluid dynamics; congenital heart defects; fetal circulation; embryonic aortic arch;
D O I
10.1016/j.jbiomech.2008.03.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study focuses on the dynamic flow through the fetal aortic arch driven by the concurrent action of right and left ventricles. We created a parametric pulsatile computational fluid dynamics (CFD) model of the fetal aortic junction with physiologic vessel geometries. To gain a better biophysical understanding, an in vitro experimental fetal flow loop for flow visualization was constructed for identical CFD conditions. CFD and in vitro experimental results were comparable. Swirling flow during the acceleration phase of the cardiac cycle and unidirectional flow following mid-deceleration phase were observed in pulmonary arteries (PA), head-neck vessels, and descending aorta. Right-to-left (oxygenated) blood flowed through the ductus arteriosus (DA) posterior relative to the antegrade left ventricular outflow tract (LVOT) stream and resembled jet flow. LVOT and right ventricular outflow tract flow mixing had not completed until similar to 3.5 descending aorta diameters downstream of the DA insertion into the aortic arch. Normal arch model flow patterns were then compared to flow patterns of four common congenital heart malformations that include aortic arch anomalies. Weak oscillatory reversing flow through the DA junction was observed only for the Tetralogy of Fallot configuration. PA and hypoplastic left heart syndrome configurations demonstrated complex, abnormal flow patterns in the PAs and head-neck vessels. Aortic coarctation resulted in large-scale recirculating flow in the aortic arch proximal to the DA. Intravascular flow patterns spatially correlated with abnormal vascular structures consistent with the paradigm that abnormal intravascular flow patterns associated with congenital heart disease influence vascular growth and function. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1697 / 1706
页数:10
相关论文
共 97 条
[1]   Fetal aortic arch measurements between 14 and 38 weeks' gestation:: in-utero ultrasonographic study [J].
Achiron, R ;
Zimand, S ;
Hegesh, J ;
Lipitz, S ;
Zalel, Y ;
Rotstein, Z .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 15 (03) :226-230
[2]  
Allan L. D., 2000, TXB FETAL CARDIOLOGY
[3]   Development of hypoplastic left heart syndrome after diagnosis of aortic stenosis in the first trimester by early echocardiography [J].
Axt-Fliedner, R. ;
Kreiselmaier, P. ;
Schwarze, A. ;
Krapp, M. ;
Gembruch, U. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (01) :106-109
[4]   Placental, fetal, and transitional circulation revisited [J].
Blackburn, Susan .
JOURNAL OF PERINATAL & NEONATAL NURSING, 2006, 20 (04) :290-294
[5]   Detection of transposition of the great arteries in fetuses reduces neonatal morbidity and mortality [J].
Bonnet, D ;
Coltri, A ;
Butera, G ;
Fermont, L ;
Le Bidois, J ;
Kachaner, J ;
Sidi, D .
CIRCULATION, 1999, 99 (07) :916-918
[6]   Outcome after prenatal diagnosis of hypoplastic left-heart syndrome: a case series [J].
Brackley, KJ ;
Kilby, MD ;
Wright, JG ;
Brawn, WJ ;
Sethia, B ;
Stumper, O ;
Holder, R ;
Wyldes, MP ;
Whittle, MJ .
LANCET, 2000, 356 (9236) :1143-1147
[7]  
BREMER JL, 1928, J ANAT, V40, P307
[8]   Fetal hemodynamics [J].
Brezinka, C .
JOURNAL OF PERINATAL MEDICINE, 2001, 29 (05) :371-380
[9]   Transitions in early embryonic atrioventricular valvular function correspond with changes in cushion biomechanics that are predictable by tissue composition [J].
Butcher, Jonathan T. ;
McQuinn, Tim C. ;
Sedmera, David ;
Turner, Debi ;
Markwald, Roger R. .
CIRCULATION RESEARCH, 2007, 100 (10) :1503-1511
[10]  
Caro CG, 1978, The mechanics of the circulation