Statistical process control for electron beam monitoring

被引:14
作者
Lopez-Tarjuelo, Juan [1 ]
Luquero-Llopis, Naika [2 ]
Garcia-Molla, Rafael [1 ]
David Quiros-Higueras, Juan [1 ]
Bouche-Babiloni, Ana [3 ]
Jordi Juan-Senabre, Xavier [1 ]
de Marco-Blancas, Noelia [1 ]
Ferrer-Albiach, Carlos [3 ,4 ]
Santos-Serra, Agustin [1 ]
机构
[1] Consorcio Hosp Prov Castellon, Serv Radiofis & Protecc Radiol, Castellon De La Plana 12002, Castellon, Spain
[2] Fdn Hosp Prov Castellon, Castellon de La Plana 12002, Spain
[3] Consorcio Hosp Prov Castellon, Serv Oncol Radioterap, Castellon de La Plana 12002, Spain
[4] Univ Cardenal Herrera, CEU, Fac Med, Castellon de La Plana 12006, Spain
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2015年 / 31卷 / 05期
关键词
Statistical process control; Control charts; Electron beam; Process capability ratio; QUALITY-ASSURANCE; RADIATION-THERAPY; IMRT QA; VERIFICATION; RADIOTHERAPY;
D O I
10.1016/j.ejmp.2015.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the electron beam monitoring statistical process control (SPC) in linear accelerator (linac) daily quality control. We present a long-term record of our measurements and evaluate which SPC-led conditions are feasible for maintaining control. Methods: We retrieved our linac beam calibration, symmetry, and flatness daily records for all electron beam energies from January 2008 to December 2013, and retrospectively studied how SPC could have been applied and which of its features could be used in the future. A set of adjustment interventions designed to maintain these parameters under control was also simulated. Results: All phase I data was under control. The dose plots were characterized by rising trends followed by steep drops caused by our attempts to re-center the linac beam calibration. Where flatness and symmetry trends were detected they were less-well defined. The process capability ratios ranged from 1.6 to 9.3 at a 2% specification level. Simulated interventions ranged from 2% to 34% of the total number of measurement sessions. We also noted that if prospective SPC had been applied it would have met quality control specifications. Conclusions: SPC can be used to assess the inherent variability of our electron beam monitoring system. It can also indicate whether a process is capable of maintaining electron parameters under control with respect to established specifications by using a daily checking device, but this is not practical unless a method to establish direct feedback from the device to the linac can be devised. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 31 条
[1]   Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control [J].
Able, Charles M. ;
Bright, Megan ;
Frizzell, Bart .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (03) :828-833
[2]   Initial investigation using statistical process control for quality control of accelerator beam steering [J].
Able, Charles M. ;
Hampton, Carnell J. ;
Baydush, Alan H. ;
Munley, Michael T. .
RADIATION ONCOLOGY, 2011, 6
[3]  
[Anonymous], 1931, EC CONTROL QUALITY M
[4]   DOSIMETRIC PRECISION REQUIREMENTS IN RADIATION-THERAPY [J].
BRAHME, A .
ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (05) :379-391
[5]  
BREEN S.Y., 2011, Quality and Safety in Radiotherapy
[6]   Statistical process control for IMRT dosimetric verification [J].
Breen, Stephen L. ;
Moseley, Douglas J. ;
Zhang, Beibei ;
Sharpe, Michael B. .
MEDICAL PHYSICS, 2008, 35 (10) :4417-4425
[7]  
CPQR CARO COMP CAMRT CPAC, 2013, MED LIN ACC MULT COL
[8]  
Deming W.E., 1986, OUT CRISIS
[9]  
DOBBS H., 1999, Physics Aspects of Quality Control in Radiotherapy
[10]   An improvement in IMRT QA results and beam matching in linacs using statistical process control [J].
Gagneur, Justin D. ;
Ezzell, Gary A. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05) :190-195