Effect of copper surface wettability on the evaporation performance: Tests in a flat-plate heat pipe with visualization

被引:49
|
作者
Wong, Shwin-Chung [1 ]
Lin, Yu-Chung [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Power Mech Engn, Hsinchu 300, Taiwan
关键词
Heat pipe; Surface wettability; Wick capillarity; Thin film evaporation; CONTACT ANGLES; RESISTANCE MEASUREMENT; EXTENDED MENISCUS; THIN-FILM; LIQUID; CAPILLARY; TRANSPORT; POLARITY; WICK;
D O I
10.1016/j.ijheatmasstransfer.2011.04.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects of copper surface wettability on the evaporation performance of a copper mesh wick were experimentally studied in an operating flat-plate heat pipe. Different degrees of wettability were obtained by varying the exposure times in air after the wicked plates were taken out of the sintering furnace. Three different working fluids: water, methanol and acetone, which possess different figures of merit, were investigated at the same volumetric liquid charge. The surface wettability was quantified by the static contact angle of sessile water drops on a flat copper surface. While the static contact angles of water drops varied from 10 degrees to 40 degrees for different degrees of wettability, the methanol and acetone drops still fully wetted the copper surface. A two-layer 100 + 200 mesh copper wick, 0.26 mm in thickness, was sintered on a 3 mm-thick copper base plate. A glass plate was adopted as the top wall of the heat pipe for visualization. Uniform heating was applied to the base plate near one end, and a cooling water jacket was connected at the other end. With increasing heat load, the evaporative resistance decreased with liquid film recession until a critical heat load showing the minimum evaporative resistance. Afterwards, partial dryout began from the front end of the evaporator. With decreasing wettability, the evaporating water film receded faster with increasing heat load and the critical heat loads were significantly reduced. In contrast, the critical heat loads for methanol and acetone seemed hardly affected by different wettability conditions. The minimum evaporative resistances, however, remained unaffected by surface wettability for all the three working fluids. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3921 / 3926
页数:6
相关论文
共 50 条
  • [1] Visualization study and analysis on the heat transfer performance of an ultra-thin flat-plate heat pipe
    Liao, Xiaonan
    Jian, Qifei
    Zu, Shuaifei
    Li, Deqiang
    Huang, Zhe
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 126
  • [2] THERMAL PERFORMANCE OF A FLAT PLATE HEAT PIPE WITH GRADIENT WETTABILITY
    Ping-Hei Chen
    Chen, Hung-Hsia
    Huang, Bo-Rui
    Long-Sheng Kuo
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 3, 2014,
  • [3] FLOW VISUALIZATION AND FLOW PATTERNS IN A FLAT-PLATE POLYPROPYLENE PULSATING HEAT PIPE
    Alqahtani A.A.
    Bertola V.
    Multiphase Science and Technology, 2023, 35 (04) : 19 - 28
  • [4] Visualization of the working fluid in a flat-plate pulsating heat pipe by neutron radiography
    Yasuda, Yosuke
    Nabeshima, Fumika
    Horiuchi, Keisuke
    Nagai, Hiroki
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 185
  • [5] EVAPORATION RESISTANCE MEASUREMENT WITH VISUALIZATION FOR SINTERED COPPER-POWDER EVAPORATOR IN OPERATING FLAT-PLATE HEAT PIPES
    Wong, Shwin-Chung
    Liou, Jhan-Hong
    Chang, Chia-Wei
    IMPACT: 2009 4TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE, 2009, : 301 - 304
  • [6] Investigation into the effect of transverse condudction on the thermal performance of a flat-plate pulsating heat pipe
    Noh, Hyung Yun
    Yoon, Aejung
    Kim, Sung Jin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 181
  • [7] Evaporation resistance measurement with visualization for sintered copper-powder evaporator in operating flat-plate heat pipes
    Wong, Shwin-Chung
    Liou, Jhan-Hong
    Chang, Chia-Wei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (19-20) : 3792 - 3798
  • [8] DESIGN AND HEAT TRANSFER PERFORMANCE OF FLAT-PLATE HEAT PIPE WITH LEAF VEINS
    Liu, Fengrui
    Li, Jinwang
    Li, Jiyuan
    HEAT TRANSFER RESEARCH, 2023, 54 (11) : 35 - 50
  • [9] THERMAL PERFORMANCE OF A FLAT-PLATE HEAT-PIPE COLLECTOR ARRAY
    BONG, TY
    NG, KC
    BAO, H
    SOLAR ENERGY, 1993, 50 (06) : 491 - 498
  • [10] Visualization and evaporator resistance measurement for a groove-wicked flat-plate heat pipe
    Wong, Shwin-Chung
    Chen, Chung-Wei