The assessment of automated measures of hydrogel contact lens refractive index

被引:20
作者
Nichols, JJ [1 ]
Berntsen, DA [1 ]
机构
[1] Ohio State Univ, Coll Optometry, Columbus, OH 43218 USA
关键词
hydrogel contact lens; refractive index; reliability; validity; water content;
D O I
10.1046/j.1475-1313.2003.00147.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate within- and between-operator reliability and validity of refractive index measures of hydrogel lenses. Methods: Twenty-three lenses of various nominal water contents were examined by two operators on two occasions separated by 1 h. An automated refractometer (CLR 12-70, Index Instruments, Cambridge, UK) was used for refractive index measures. Lenses were presented in a random order to each operator by a third party, and operators were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement (LoA), and paired t-tests were used to characterize the within- and between-operator reliability and validity of lens refractive index measures. Results: The mean (+/-S.D.) difference between sessions was 0.0001 +/- 0.0011, which did not significantly differ from zero (p = 0.64). Within-operator reliability was excellent (ICC = 0.9990, 95% LoA = -0.0021 to 0.0024). The mean (+/-S.D.) difference between-operators was 0.0002 +/- 0.0010, which was not significantly different from zero (p = 0.54). Between-operator reliability was also excellent (ICC = 0.9984, 95% LoA = -0.0026 to 0.0029). The mean difference between the nominally reported refractive index and our refractive index measures was -0.0009 +/- 0.082, which did not differ statistically from zero (p = 0.52); the 95% LoA for this difference was -0.0152 to 0.0169. Conclusion: There is good reliability within- and between-operators in measuring the refractive index of hydrogel lenses using the CLR 12-70 automated refractometer.
引用
收藏
页码:517 / 525
页数:9
相关论文
共 47 条
  • [1] THE EFFECTS OF HYPOTONIC AND HYPERTONIC SOLUTIONS ON THE FLUID CONTENT OF HYDROPHILIC CONTACT-LENSES
    AIELLO, JP
    INSLER, MS
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 99 (05) : 521 - 523
  • [2] Alemany Antonio Lopez, 2000, CLAO Journal, V26, P200
  • [3] ANDRASKO G, 1982, J AM OPTOM ASSOC, V53, P207
  • [4] Andrasko G., 1983, ICLC, P22
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] INVIVO DEHYDRATION OF DISPOSABLE (ACUVUE) CONTACT-LENSES
    BRENNAN, NA
    LOWE, R
    EFRON, N
    HARRIS, MG
    [J]. OPTOMETRY AND VISION SCIENCE, 1990, 67 (03) : 201 - 203
  • [7] Bruce A S, 1989, J Am Optom Assoc, V60, P581
  • [8] DEDONATO LM, 1982, AM J OPTOM PHYS OPT, V59, P213
  • [9] EFRON N, 1987, CLAO Journal, V13, P152
  • [10] EFRON N, 1988, OPHTHAL PHYSL OPT, V8, P253, DOI 10.1016/0275-5408(88)90176-7