Accelerated 4D Quantitative Single Point EPR Imaging Using Model-Based Reconstruction

被引:8
|
作者
Jang, Hyungseok [1 ]
Matsumoto, Shingo [2 ]
Devasahayam, Nallathamby [2 ]
Subramanian, Sankaran [2 ]
Zhuo, Jiachen [3 ]
Krishna, Murali C. [2 ]
McMillan, Alan B. [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Wisconsin Inst Med Res, Madison, WI 53705 USA
[2] NCI, Radiat Biol Branch, Ctr Canc Res, NIH, Bethesda, MD 20892 USA
[3] Univ Maryland, Dept Diagnost Radiol & Nucl Med, Baltimore, MD 21201 USA
基金
美国国家卫生研究院;
关键词
Electron paramagnetic resonance imaging; quantitative imaging; single-point imaging; model-based reconstruction; k-space extrapolation; UNDERSAMPLED DATA; RESOLUTION; MRI; ACQUISITION;
D O I
10.1002/mrm.25282
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeElectron paramagnetic resonance imaging has surfaced as a promising noninvasive imaging modality that is capable of imaging tissue oxygenation. Due to extremely short spin-spin relaxation times, electron paramagnetic resonance imaging benefits from single-point imaging and inherently suffers from limited spatial and temporal resolution, preventing localization of small hypoxic tissues and differentiation of hypoxia dynamics, making accelerated imaging a crucial issue. MethodsIn this study, methods for accelerated single-point imaging were developed by combining a bilateral k-space extrapolation technique with model-based reconstruction that benefits from dense sampling in the parameter domain (measurement of the T-2(*) decay of a free induction delay). In bilateral kspace extrapolation, more k-space samples are obtained in a sparsely sampled region by bilaterally extrapolating data from temporally neighboring k-spaces. To improve the accuracy of T-2(*) estimation, a principal component analysis-based method was implemented. ResultsIn a computer simulation and a phantom experiment, the proposed methods showed its capability for reliable T-2(*) estimation with high acceleration (8-fold, 15-fold, and 30-fold accelerations for 61x61x61, 95x95x95, and 127x127x127 matrix, respectively). ConclusionBy applying bilateral k-space extrapolation and model-based reconstruction, improved scan times with higher spatial resolution can be achieved in the current single-point electron paramagnetic resonance imaging modality. Magn Reson Med 73:1692-1701, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1692 / 1701
页数:10
相关论文
共 50 条
  • [11] Quality-Enhancing Techniques for Model-Based Reconstruction in Magnetic Particle Imaging
    Gapyak, Vladyslav
    Marz, Thomas
    Weinmann, Andreas
    MATHEMATICS, 2022, 10 (18)
  • [12] Accelerated model-based quantitative diffusion MRI A feasibility study for musculoskeletal application
    Huefken, Thomas
    Arbogast, Jannik M.
    Bracher, Anna-Katinka
    Beer, Meinrad
    Neubauer, Henning
    Rasche, Volker
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (02): : 240 - 247
  • [13] Quantitative Dual-Energy Imaging in the Presence of Metal Implants Using Locally Constrained Model-Based Decomposition
    Liu, Stephen Z.
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    Zbijewski, Wojciech
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [14] Volumetric object reconstruction using the 3D-MRF model-based segmentation
    Choi, SM
    Lee, JE
    Kim, J
    Kim, MH
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) : 887 - 892
  • [15] Model-based iterative reconstruction for single-shot EPI at 7T
    Yarach, Uten
    In, Myung-Ho
    Chatnuntawech, Itthi
    Bilgic, Berkin
    Godenschweger, Frank
    Mattern, Hendrik
    Sciarra, Alessandro
    Speck, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2250 - 2264
  • [16] Phase reconstruction using fast binary 4D STEM data
    O'Leary, C. M.
    Allen, C. S.
    Huang, C.
    Kim, J. S.
    Liberti, E.
    Nellist, P. D.
    Kirkland, A. I.
    APPLIED PHYSICS LETTERS, 2020, 116 (12)
  • [17] 4D Imaging based on the Fresnel Incoherent Correlation Holography
    Shi, Xia
    Yuan, Bin
    Zhu, Wufeng
    Liang, Erjun
    Liu, Xiaomin
    Ma, Fengying
    HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS VI, 2014, 9271
  • [18] 4D microvascular imaging based on ultrafast Doppler tomography
    Demene, Charlie
    Tiran, Elodie
    Sieu, Lim-Anna
    Bergel, Antoine
    Gennisson, Jean Luc
    Pernot, Mathieu
    Deffieux, Thomas
    Cohen, Ivan
    Tanter, Mickael
    NEUROIMAGE, 2016, 127 : 472 - 483
  • [19] Model-Based Reconstruction for Highly Accelerated First-Pass Perfusion Cardiac MRI
    Correia, Teresa
    Schneider, Torben
    Chiribiri, Amedeo
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT II, 2019, 11765 : 514 - 522
  • [20] A patient specific 4D MRI liver motion model based on sparse imaging and registration
    Noorda, Yolanda H.
    Bartels, Lambertus W.
    van Stralen, Marijn
    Pluim, Josien P. W.
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671