Desynchronization of the mu oscillatory activity during motor imagery: A preliminary EEG-fMRI study

被引:0
作者
Kim, Hyun-Chul [1 ]
Lee, Jong-Hwan [1 ]
机构
[1] Korea Univ, Dept Brain & Cognit Engn, Seoul, South Korea
来源
3RD INTERNATIONAL WINTER CONFERENCE ON BRAIN-COMPUTER INTERFACE | 2015年
关键词
Electroencephalography (EEG); functional magnetic resonance imaging (fMRI); mu rhythmic power; motor imagery; simultaneous EEG-fMRI; COMPONENT ANALYSIS; ARTIFACTS;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The purpose of this study is to identify the correspondence between distinct brain oscillatory activity acquired from electroencephalography (EEG) and blood oxygenation level dependent signals obtained from functional magnetic resonance imaging (fMRI). In this preliminary study, the changes in the mu rhythmic power (8-13Hz) during motor imagery tasks in the EEG data simultaneously acquired with fMRI data were examined. The average mu powers during the left-hand (LH)/right-hand (RH) motor imagery tasks were separately estimated after removing dominant artifacts, such as gradient artifact, ballistocardiogram artifact, and helium-pump artifact. As a result, the relatively lower mu power of the contralateral motor area during LH/RH motor imagery tasks was observed compared to ipsilateral side. This observation indicates a functional signature for motor imagery tasks.
引用
收藏
页码:21 / 22
页数:2
相关论文
共 8 条
[1]   A method for removing imaging artifact from continuous EEG recorded during functional MRI [J].
Allen, PJ ;
Josephs, O ;
Turner, R .
NEUROIMAGE, 2000, 12 (02) :230-239
[2]  
Berger H, 1930, J PSYCHOL NEUROL, V40, P160
[3]   The spatiospectral characterization of brain networks: Fusing concurrent EEG spectra and fMRI maps [J].
Bridwell, David A. ;
Wu, Lei ;
Eichele, Tom ;
Calhoun, Vince D. .
NEUROIMAGE, 2013, 69 :101-111
[4]   EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis [J].
Delorme, A ;
Makeig, S .
JOURNAL OF NEUROSCIENCE METHODS, 2004, 134 (01) :9-21
[5]   Recursive approach of EEG-segment-based principal component analysis substantially reduces cryogenic pump artifacts in simultaneous EEG-fMRI data [J].
Kim, Hyun-Chul ;
Yoo, Seung-Schik ;
Lee, Jong-Hwan .
NEUROIMAGE, 2015, 104 :437-451
[6]   Removal of FMRI environment artifacts from EEG data using optimal basis sets [J].
Niazy, RK ;
Beckmann, CF ;
Iannetti, GD ;
Brady, JM ;
Smith, SM .
NEUROIMAGE, 2005, 28 (03) :720-737
[7]   Mu rhythm (de)synchronization and EEG single-trial classification of different motor imagery tasks [J].
Pfurtscheller, G. ;
Brunner, C. ;
Schloegl, A. ;
da Silva, F. H. Lopes .
NEUROIMAGE, 2006, 31 (01) :153-159
[8]   Event-related EEG/MEG synchronization and desynchronization: basic principles [J].
Pfurtscheller, G ;
da Silva, FHL .
CLINICAL NEUROPHYSIOLOGY, 1999, 110 (11) :1842-1857