Digital vs Conventional Implant Impressions: A Systematic Review and Meta-Analysis

被引:109
|
作者
Papaspyridakos, Panos [1 ,2 ]
Vazouras, Konstantinos [1 ]
Chen, Yo-wei [1 ]
Kotina, Elli
Natto, Zuhair [3 ,4 ]
Kang, Kiho [1 ]
Chochlidakis, Konstantinos [2 ]
机构
[1] Tufts Univ, Sch Dent Med, Dept Prosthodont, 1 Kneeland St, Boston, MA 02111 USA
[2] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, Rochester, NY USA
[3] King Abdulaziz Univ, Dept Dent Publ Hlth, Jeddah, Saudi Arabia
[4] Tufts Univ, Sch Dent Med, Dept Periodontol, Boston, MA 02111 USA
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2020年 / 29卷 / 08期
关键词
Accuracy of implant impressions; completely edentulous; conventional impressions; digital implant scans; digital impressions; partially edentulous; 3-DIMENSIONAL ACCURACY; IN-VITRO; DENTAL IMPLANTS; EDENTULOUS PATIENTS; GUIDED SURGERY; CASTS; TECHNOLOGY; WORKFLOW; FIT; REHABILITATION;
D O I
10.1111/jopr.13211
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To systematically review in vitro and clinical studies comparing quantitatively the 3D accuracy (global implant deviations) of digital vs conventional implant impressions for partially and completely edentulous patients. Materials and Methods Electronic and manual searches were conducted to identify in vitro and clinical studies, reporting on the 3D accuracy between digital and conventional implant impressions. Secondary outcomes were the effect of implant angulation, type of conventional impression technique, and type of intraoral scanner on the accuracy of implant impressions. Results The inclusion criteria were met by 9 in vitro studies and 1 clinical study reporting on completely edentulous impressions, while 6 in vitro and 2 clinical studies reported on partially edentulous impressions. Quantitative meta-analysis was performed for 5 completely edentulous and 6 partially edentulous studies. The studies exhibited high values for heterogeneity. A random effects model was conducted to estimate the effect size. Based on 5 in vitro studies on completely edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 8.20 mu m (95% CI: -53.56, 37.15) and the digital impressions had nominally less deviation (p =0.72). Based on 1 clinical and 5 in vitro studies on partially edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 52.31 mu m (95% CI: 6.30, 98.33) and the conventional impressions had nominally less deviation (p= 0.03). Five in vitro and 2 clinical studies were not included in the quantitative analysis due to heterogeneity in the methodology. Implant angulation affected the accuracy in favor of the partially edentulous conventional impressions whereas the effect of different scanners was not statistically significant on the completely edentulous impressions (p= 0.82). Conclusions Digital scans appear to have comparable 3D accuracy with conventional implant impressions based mainly on in vitro studies. However, clinical trials are recommended to investigate the clinical accuracy of digital scans and digitally fabricated interim or prototype prostheses, before digital implant scans can be recommended for routine clinical use.
引用
收藏
页码:660 / 678
页数:19
相关论文
共 50 条
  • [41] The Frequency of Peri-Implant Diseases: A Systematic Review and Meta-Analysis
    Atieh, Momen A.
    Alsabeeha, Nabeel H. M.
    Faggion, Clovis Mariano, Jr.
    Duncan, Warwick J.
    JOURNAL OF PERIODONTOLOGY, 2013, 84 (11) : 1586 - 1598
  • [42] Patient preference and clinical working time between digital scanning and conventional impression making for implant- supported prostheses: A systematic review and meta-analysis
    Manicone, Paolo Francesco
    De Angelis, Paolo
    Rella, Edoardo
    Damis, Giovanni
    D'addona, Antonio
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04) : 589 - 596
  • [43] The Effect of Antidepressants on Dental Implant Failure: A Systematic Review and Meta-analysis
    Harutyunyan, Liza
    Lieuw, Kayla
    Yang, Bryan
    Lee, Eric
    Yeh, Yu-Ting
    Chen, Hsuan-Hung
    Lin, Guo-Hao
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (05) : 665 - 673b
  • [44] The effect of photobiomodulation therapy on implant stability: A systematic review and meta-analysis
    Arshad, Mahnaz
    Mazidi, Yekta
    Chiniforush, Nasim
    Shirvani, Armin
    Bassir, Seyed Hossein
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2024,
  • [45] The effect of antiresorptive drugs on implant therapy: Systematic review and meta-analysis
    Stavropoulos, Andreas
    Bertl, Kristina
    Pietschmann, Peter
    Pandis, Nikolaos
    Schiodt, Morten
    Klinge, Bjorn
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 54 - 92
  • [46] Immediate implant placement in compromised sockets: A systematic review and meta-analysis
    Amid, Reza
    Kadkhodazadeh, Mahdi
    Moscowchi, Anahita
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (03) : 307 - 317
  • [47] Implant Health in Treated Periodontitis Patients: A Systematic Review and Meta-Analysis
    Marty, Lea
    Hoornaert, Alain
    Enkel, Benedicte
    Penhoat, Alan
    Colat-Parros, Jacques
    Soueidan, Assem
    Jordana, Fabienne
    DENTISTRY JOURNAL, 2024, 12 (08)
  • [48] Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis
    Basaki, Kinga
    Alkumru, Hasan
    De Souza, Grace
    Finer, Yoav
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 792 - 799
  • [49] Differences in Dental Implant Survival between Immediate vs. Delayed Placement: A Systematic Review and Meta-Analysis
    Patel, Rishi
    Ucer, Cemal
    Wright, Simon
    Khan, Rabia S.
    DENTISTRY JOURNAL, 2023, 11 (09)
  • [50] Digital Impressions in Implant Dentistry: A Literature Review
    Marques, Simone
    Ribeiro, Paulo
    Falcao, Carlos
    Lemos, Bernardo Ferreira
    Rios-Carrasco, Blanca
    Rios-Santos, Jose Vicente
    Herrero-Climent, Mariano
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (03) : 1 - 20