Digital vs Conventional Implant Impressions: A Systematic Review and Meta-Analysis

被引:109
|
作者
Papaspyridakos, Panos [1 ,2 ]
Vazouras, Konstantinos [1 ]
Chen, Yo-wei [1 ]
Kotina, Elli
Natto, Zuhair [3 ,4 ]
Kang, Kiho [1 ]
Chochlidakis, Konstantinos [2 ]
机构
[1] Tufts Univ, Sch Dent Med, Dept Prosthodont, 1 Kneeland St, Boston, MA 02111 USA
[2] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, Rochester, NY USA
[3] King Abdulaziz Univ, Dept Dent Publ Hlth, Jeddah, Saudi Arabia
[4] Tufts Univ, Sch Dent Med, Dept Periodontol, Boston, MA 02111 USA
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2020年 / 29卷 / 08期
关键词
Accuracy of implant impressions; completely edentulous; conventional impressions; digital implant scans; digital impressions; partially edentulous; 3-DIMENSIONAL ACCURACY; IN-VITRO; DENTAL IMPLANTS; EDENTULOUS PATIENTS; GUIDED SURGERY; CASTS; TECHNOLOGY; WORKFLOW; FIT; REHABILITATION;
D O I
10.1111/jopr.13211
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To systematically review in vitro and clinical studies comparing quantitatively the 3D accuracy (global implant deviations) of digital vs conventional implant impressions for partially and completely edentulous patients. Materials and Methods Electronic and manual searches were conducted to identify in vitro and clinical studies, reporting on the 3D accuracy between digital and conventional implant impressions. Secondary outcomes were the effect of implant angulation, type of conventional impression technique, and type of intraoral scanner on the accuracy of implant impressions. Results The inclusion criteria were met by 9 in vitro studies and 1 clinical study reporting on completely edentulous impressions, while 6 in vitro and 2 clinical studies reported on partially edentulous impressions. Quantitative meta-analysis was performed for 5 completely edentulous and 6 partially edentulous studies. The studies exhibited high values for heterogeneity. A random effects model was conducted to estimate the effect size. Based on 5 in vitro studies on completely edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 8.20 mu m (95% CI: -53.56, 37.15) and the digital impressions had nominally less deviation (p =0.72). Based on 1 clinical and 5 in vitro studies on partially edentulous impressions, the mean 3D implant deviation between conventional and digital impressions was 52.31 mu m (95% CI: 6.30, 98.33) and the conventional impressions had nominally less deviation (p= 0.03). Five in vitro and 2 clinical studies were not included in the quantitative analysis due to heterogeneity in the methodology. Implant angulation affected the accuracy in favor of the partially edentulous conventional impressions whereas the effect of different scanners was not statistically significant on the completely edentulous impressions (p= 0.82). Conclusions Digital scans appear to have comparable 3D accuracy with conventional implant impressions based mainly on in vitro studies. However, clinical trials are recommended to investigate the clinical accuracy of digital scans and digitally fabricated interim or prototype prostheses, before digital implant scans can be recommended for routine clinical use.
引用
收藏
页码:660 / 678
页数:19
相关论文
共 50 条
  • [21] Evaluation of the Effect of Digital Dentistry on the Accuracy of Implant Placement and Prosthesis Fabrication-A Systematic Review and Meta-Analysis
    Reddy, Naveen
    Vempalli, Swetha
    Prakash, Jayant
    Suganna, Mahesh
    Meenakshi, Srinivasa Iyer
    Shivakumar, Ganiga Channaiah
    Crimi, Salvatore
    Minervini, Giuseppe
    PROSTHESIS, 2023, 5 (03): : 666 - 677
  • [22] Immediate vs Conventional Loading of Mandibular Overdentures: A Comprehensive Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Ye, Mingfu
    Liu, Wenjun
    Cheng, Shaolong
    Yan, Lihui
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (01) : 64 - 73
  • [23] Implant stability using piezoelectric bone surgery compared with conventional drilling: a systematic review and meta-analysis
    Garcia-Moreno, S.
    Gonzalez-Serrano, J.
    Lopez-Pintor, R. M.
    Pardal-Pelaez, B.
    Hernandez, G.
    Martinez-Gonzalez, J. M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 47 (11) : 1453 - 1464
  • [24] Marginal adaptation of zirconia complete-coverage fixed dental restorations made from digital scans or conventional impressions: A systematic review and meta-analysis
    Tabesh, Mahtab
    Nejatidanesh, Farahnaz
    Savabi, Ghazal
    Davoudi, Amin
    Savabi, Omid
    Mirmohammadi, Hesam
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (04) : 603 - 610
  • [25] Accuracy in the Marginal Adaptation and/or Internal Adaptation of Full-coverage Fixed Prostheses Made with Digital Impressions and Conventional Impressions: A Systematic Review
    Cajas-Guaman, Maria
    Cabrera-Toro, Maria
    Astudillo-Ortiz, Jaime
    Abad-Salinas, Yulissa
    Astudillo-Rubio, Daniela
    Delgado-Gaete, Bolivar
    OPEN DENTISTRY JOURNAL, 2023, 17
  • [26] Adhesion of Candida Albicans to digital versus conventional acrylic resins: a systematic review and meta-analysis
    Alhajj, Mohammed Nasser
    Halboub, Esam
    Yacob, Norlela
    Al-Maweri, Sadeq Ali
    Ahmad, Siti Fauzza
    Celebic, Asja
    Al-Mekhlafi, Hesham M.
    Salleh, Nosizana Mohd
    BMC ORAL HEALTH, 2024, 24 (01)
  • [27] Modeling of Crestal Bone After Submerged vs Transmucosal Implant Placement: A Systematic Review with Meta-Analysis
    Paul, Stefan
    Petsch, Matthias
    Held, Ulrike
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (05) : 1039 - 1050
  • [28] Trueness and precision of digital implant impressions by intraoral scanners: a literature review
    Sanda, Minoru
    Miyoshi, Keita
    Baba, Kazuyoshi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [29] THE ACCURACY OF INTRAORAL SCAN IN OBTAINING DIGITAL IMPRESSIONS OF EDENTULOUS ARCHES: A SYSTEMATIC REVIEW
    Wang, Yiyang
    Li, Yaning
    Liang, Shanshan
    Yuan, Fusong
    Liu, Yunsong
    Ye, Hongqiang
    Zhou, Yongsheng
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2024, 24 (01)
  • [30] Accuracy of Implant Impressions for Partially and Completely Edentulous Patients: A Systematic Review
    Papaspyridakos, Panos
    Chen, Chun-Jung
    Gallucci, German O.
    Doukoudakis, Asterios
    Weber, Hans-Peter
    Chronopoulos, Vasilios
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (04) : 836 - +