Pulse oximetry

被引:0
作者
McMorrow, Roger C. N. [1 ]
Mythen, Michael G. [2 ]
机构
[1] Rotunda Hosp, Anaesthet SpR, Dublin 1, Ireland
[2] UCL Inst Child Hlth, Portex Anaesthesia Intens Care & Resp Unit, London, England
关键词
monitoring oxygenation; non-invasive; pulse oximetry;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of review Pulse oximetry is now a ubiquitous and essential tool of modern medicine, and while it is a relatively recent invention, the technology has rapidly matured since the first commercially available oximeters were introduced in the 1970s. This review seeks to provide an overview of the basic physical operation of the probe and discuss its limitations, sources of error and some current advances in the use of multi-wavelength probes. Recent findings New multi-wavelength oximeters and plethysmographic waveform analysis may expand the information that we can collect and use non-invasively. This includes distinguishing between haemoglobinopathies, monitoring volume status and volume loss, and potentially monitoring cardiac output non-invasively. Summary The pulse oximeter, like any. basic tool, must be used properly. There, is considerable misunderstanding and lack of education among junior clinicians as to the use and interpretation of pulse oximeters. The introduction of the pulse oximeter has demonstrated a cost saving, although the cost-benefit of new multi-wavelength probes remains unproven.
引用
收藏
页码:269 / 271
页数:3
相关论文
共 33 条
[1]   FLUORESCENT LIGHT INTERFERES WITH PULSE OXIMETRY [J].
AMAR, D ;
NEIDZWSKI, J ;
WALD, A ;
FINCK, AD .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (02) :135-136
[2]   EFFECTS OF METHEMOGLOBINEMIA ON PULSE OXIMETRY AND MIXED VENOUS OXIMETRY [J].
BARKER, SJ ;
TREMPER, KK ;
HYATT, J .
ANESTHESIOLOGY, 1989, 70 (01) :112-117
[3]   PULSE OXIMETRY IN THE POSTOPERATIVE CARE OF CARDIAC SURGICAL PATIENTS - A RANDOMIZED CONTROLLED TRIAL [J].
BIERMAN, MI ;
STEIN, KL ;
SNYDER, JV .
CHEST, 1992, 102 (05) :1367-1370
[4]   PULSE OXIMETRY MONITORING OUTSIDE THE INTENSIVE-CARE UNIT - PROGRESS OF PROBLEM [J].
BOWTON, DL ;
SCUDERI, PE ;
HARRIS, L ;
HAPONIK, EF .
ANNALS OF INTERNAL MEDICINE, 1991, 115 (06) :450-454
[5]   THE PULSE OXIMETRY GAP IN CARBON-MONOXIDE INTOXICATION [J].
BUCKLEY, RG ;
AKS, SE ;
ESHOM, JL ;
RYDMAN, R ;
SCHAIDER, J ;
SHAYNE, P .
ANNALS OF EMERGENCY MEDICINE, 1994, 24 (02) :252-255
[6]  
CHELLURI L, 1991, Respiratory Care, V36, P1383
[7]   A COMPARISON OF THE PERFORMANCE OF 20 PULSE OXIMETERS UNDER CONDITIONS OF POOR PERFUSION [J].
CLAYTON, DG ;
WEBB, RK ;
RALSTON, AC ;
DUTHIE, D ;
RUNCIMAN, WB .
ANAESTHESIA, 1991, 46 (01) :3-10
[8]   Evaluation of pulse oximetry in sickle cell anemia patients presenting to the emergency department in acute vasoocclusive crisis [J].
Comber, JT ;
Lopez, BL .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1996, 14 (01) :16-18
[9]  
COMROE JH, 1947, AM J MED SCI, V214, P1
[10]  
COTE CJ, 1988, ANESTH ANALG, V67, P683