An Analysis of the Structures at Risk from Percutaneous Pinning of Distal Radius Fractures and a Comparison of Two Pinning Techniques: A Cadaveric Study

被引:0
|
作者
Kamble, Prashant [1 ,2 ]
Prabhakar, Akil S. [1 ,2 ]
Mohanty, Shubhranshu S. [1 ,2 ]
Prabhu, Rudra M. [1 ,2 ]
Keny, Swapnil [1 ,2 ]
Panchal, Sameer [3 ]
机构
[1] Seth GS Med Coll, Dept Orthopaed, Mumbai, Maharashtra, India
[2] King Edward Mem Hosp, Bombay, Maharashtra, India
[3] Sir HN Reliance Fdn Hosp & Res Ctr, Dept Orthopaed, Mumbai, Maharashtra, India
关键词
Superficial radial nerve injury; Percutaneous pinning; Distal radius fracture; K-wire; Tendon injury; KIRSCHNER-WIRE PLACEMENT; SUPERFICIAL BRANCH; NERVE;
D O I
10.1142/S2424835522500850
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: A stab incision and blunt dissection prior to wire placement are believed to decrease the risk of injury to underlying structures during percutaneous pinning of distal radius fractures (DRF). However, only a few studies have compared stab incision and blunt dissection to direct wire placement. The aim of this cadaveric study is to analyse the structures at risk during percutaneous pinning of DRF and compare the two methods of wire placement. Methods: A total of 10 cadavers (20 upper limbs) were divided into two groups of five each. Five 2.0 mm Kirschner (K)-wires were inserted into the distal radius under fluoroscopic control in a standard fashion to simulate percutaneous pinning of DRF. In group 1, the K-wires were inserted directly, whereas in group 2, the wires were inserted after making a stab incision and blunt dissection to reach the bone. Each cadaveric limb was then dissected carefully to measure the distance of the K-wires from the branches of the superficial radial nerve (SRN), the cephalic vein and the first dorsal compartment and to determine the structures injured (pierced or in close contact) by the K-wires. Results: Out of the 100 K-wires placed, 18 wires were in close contact or pierced an underlying structure. These included 11 wires injuring tendons, six wires injuring branches of the SRN and one wire injuring the cephalic vein. Direct wire placement (group 1) resulted in injury to eight structures (44.4%) while stab incision and blunt dissection prior to wire placement (group 2) resulted in injury to 10 structures (55.5%). This difference was not statistically significant. Conclusions: Percutaneous pinning of OAF is associated with a high risk of injury to the extensor tendons and branches of the SRN. This risk is not reduced by making a stab incision and blunt dissection prior to K-wire placement.
引用
收藏
页码:772 / 781
页数:10
相关论文
共 30 条
  • [1] Percutaneous Pinning of Distal Radius Fractures: An Anatomic Study Demonstrating the Proximity of K-Wires to Structures at Risk
    Chia, Benjamin
    Catalano, Louis W., III
    Glickel, Steven Z.
    Barron, O. Alton
    Meier, Kristen
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (06): : 1014 - 1020
  • [2] Is percutaneous pinning an outdated technique for distal radius fractures?
    Rupp, Markus
    Cambon-Binder, Adeline
    Alt, Volker
    Feron, Jean-Marc
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 : S30 - S35
  • [3] Percutaneous Distal Radius-Ulna Pinning of Distal Radius Fractures to Prevent Settling
    Kim, Jin Young
    Tae, Suk Kee
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (10): : 1921 - 1925
  • [4] Distal Radius Fractures: Nonoperative and Percutaneous Pinning Treatment Options
    Gofton, Wade
    Liew, Allan
    HAND CLINICS, 2010, 26 (01) : 43 - 53
  • [5] Functional and radiological outcome of percutaneous pinning for fractures of distal radius
    Atiq, Ghulam
    Hassan, Waqar
    Khan, Ayub Nawaz
    Hassan, Mahmood-ul
    RAWAL MEDICAL JOURNAL, 2013, 38 (02): : 156 - 159
  • [6] Percutaneous pinning versus pin-in-plaster for treatment of distal radius fractures
    Tajeddin, Farhang
    Esmaeilnejadganji, Seyyed Mokhtar
    BaghianiMoghaddam, Behnam
    Ahangar, Sekineh Kamali
    Feridoni, Masood Bahrami
    CASPIAN JOURNAL OF INTERNAL MEDICINE, 2019, 10 (03) : 309 - 313
  • [7] Single versus double percutaneous pinning of pediatric distal radius fractures
    Beatty, Evan W.
    Osada, Koya
    Zbeda, Robert M.
    Bae, Donald S.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2025, 34 (02): : 128 - 133
  • [8] Percutaneous pinning for non-comminuted extraarticular fractures of distal radius
    Abhishek K. Das
    Nandkumar Sundaram
    Thiruvengita G. Prasad
    Suresh K. Thanhavelu
    Indian Journal of Orthopaedics, 2011, 45 : 422 - 426
  • [9] Distal Radius Fractures: Evaluation of Closed Reduction and Percutaneous Kirschner Wire Pinning
    Ozkan, Sezai
    Westenberg, Ritsaart F.
    Helliwell, Lydia A.
    Mudgal, Chaitanya S.
    JOURNAL OF HAND AND MICROSURGERY, 2018, 10 (03) : 134 - 138
  • [10] Percutaneous pinning for non-comminuted extra-articular fractures of distal radius
    Das, Abhishek K.
    Sundaram, Nandkumar
    Prasad, Thiruvengita G.
    Thanhavelu, Suresh K.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (05) : 422 - 426