Validation of prompt gamma-ray spectroscopy for proton range verification in tissue-mimicking and porcine samples

被引:6
|
作者
Tattenberg, Sebastian [1 ,2 ,3 ]
Marants, Raanan [3 ,4 ]
Niepel, Katharina [1 ]
Bortfeld, Thomas [2 ,3 ]
Sudhyadhom, Atchar [3 ,4 ]
Landry, Guillaume [5 ,6 ]
Parodi, Katia [1 ]
Verburg, Joost [2 ,3 ]
机构
[1] Ludwig Maximilians Univ Munchen, Fac Phys, Dept Med Phys, Garching, Germany
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Div Radiat Biophys, Boston, MA 02114 USA
[3] Harvard Med Sch, Boston, MA 02115 USA
[4] Brigham & Womens Hosp, Dept Radiat Oncol, Dana Farber Canc Inst, 75 Francis St, Boston, MA 02115 USA
[5] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiat Oncol, Munich, Germany
[6] German Canc Consortium DKTK, Partner Site Munich, Munich, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 20期
关键词
range uncertainty; proton therapy; range verification; prompt gamma-ray spectroscopy; EMISSION; SIMULATION; PATIENT; PET;
D O I
10.1088/1361-6560/ac950f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Proton therapy of cancer improves dose conformality to the target and sparing of surrounding healthy tissues compared to conventional photon treatments. However, proton therapy's advantage could be even larger if proton range uncertainties were reduced. Sources of range uncertainties include computed tomography treatment planning images and variations in patient anatomy and setup. To reduce range uncertainties, we have developed a system for real-time in vivo range monitoring. The system is based on spectroscopy of prompt gamma-rays emitted through proton-nuclear interactions during irradiation. We validated the performance of our prompt gamm-aray spectroscopy detector prototype using tissue-mimicking and porcine samples. Approach. Measurements were performed in water, four tissue-mimicking samples (spongiosa, muscle, adipose tissue, and cortical bone), and two porcine samples (liver and brain). A dose of 0.9 Gy was delivered to a target at a depth of 12.5-17.5 cm. Multi-layer ionization chamber measurements were performed to determine stopping power ratios relative to water and ground truth proton ranges. Ground truth elemental compositions were determined using combustion analysis. Proton ranges and elemental compositions measured using prompt gamma-ray spectroscopy were compared to the ground truth. Main results. For all samples, the mean measured range over all pencil-beam spots differed from the ground truth by less than 1.2 mm. The mean standard deviation was 0.9 mm (range: 0.4 1.6 mm). The mean difference between ground truth and measured elemental compositions was 0.06 8/cm(3) (range: 0.00 g/cm(3) to 0.12 g/cm(3)). Significance. We verified the performance of our prompt gamma-ray spectroscopy detector prototype for proton range verification using tissue-mimicking and porcine samples. Measured proton ranges and elemental sample compositions were in good agreement with the ground truth. These measurements confirm the system's reliability for a variety of tissues and bridge the gap between previously-reported experiments and ongoing in vivo patient measurements.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] ABSOLUTE, PROMPT GAMMA-RAY SPECTROSCOPY AND THE DETERMINATION OF FUNDAMENTAL CONSTANTS
    DESLATTES, RD
    GREENE, GL
    KESSLER, EG
    JOURNAL DE PHYSIQUE, 1984, 45 (NC-3): : 41 - 46
  • [32] PROMPT GAMMA-RAY SPECTROSCOPY AND ITS USE IN ELEMENTAL ANALYSIS
    DECONNINCK, G
    DEMORTIER, G
    BODART, F
    ATOMIC ENERGY REVIEW, 1981, : 151 - 234
  • [33] Prompt Gamma Ray Spectroscopy of Contrast Agents in Proton Radiotherapy
    Kasanda, E.
    Muecher, D.
    Bildstein, V.
    Turko, J.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [34] Validation of Nuclear Reaction Models to Simulate Proton Therapy Range Verification Using Prompt Gamma-Rays
    Verburg, J.
    Shih, H.
    Seco, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3860 - 3860
  • [35] Proton bunch monitors for the clinical translation of prompt gamma-ray timing
    Makarevich, Krystsina
    Schellhammer, Sonja M.
    Pausch, Guntram
    Roemer, Katja E.
    Tiebel, Jessica
    Turko, Joseph
    Wagner, Andreas
    Koegler, Toni
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (22):
  • [36] Development of a new prompt gamma ray detection system for full 3D proton range verification
    Costanza, P.
    Mackay, R. I.
    Kirkby, K. J.
    Taylor, M. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S957 - S958
  • [37] Gamma-ray spectroscopy beyond the proton drip line
    Yu, CH
    Batchelder, JC
    Bingham, CR
    Gross, CJ
    Grzywacz, R
    Rykaczewski, K
    PROTON-EMITTING NUCLEI, 2003, 681 : 172 - 182
  • [38] Spectroscopic study of prompt-gamma emission for range verification in proton therapy
    Kelleter, Laurent
    Wronska, Aleksandra
    Besuglow, Judith
    Konefal, Adam
    Laihem, Karim
    Leidner, Johannes
    Magiera, Andrzej
    Parodi, Katia
    Rusiecka, Katarzyna
    Stahl, Achim
    Tessonnier, Thomas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 34 : 7 - 17
  • [39] A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy
    Draeger, E.
    Chen, H.
    Mackin, D.
    Peterson, S.
    Avery, S.
    Beddar, S.
    Polf, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3757 - 3757
  • [40] 3D prompt gamma imaging for proton beam range verification
    Draeger, E.
    Mackin, D.
    Peterson, S.
    Chen, H.
    Avery, S.
    Beddar, S.
    Polf, J. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):