Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration

被引:178
|
作者
Barnes, EIA
Murray, BR
Robinson, DM
Underwood, LJ
Hanson, J
Roa, WHY
机构
[1] Cross Canc Inst, Dept Radiat Oncol, Edmonton, AB T6G 1Z2, Canada
[2] Cross Canc Inst, Dept Med Phys, Edmonton, AB T6G 1Z2, Canada
[3] Cross Canc Inst, Dept Epidemiol, Edmonton, AB T6G 1Z2, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 50卷 / 04期
关键词
lung cancer; radiotherapy; respiration gating; self-gating; deep-inspiration breath hold;
D O I
10.1016/S0360-3016(01)01592-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose:To examine the dosimetric benefit of self-gated radiotherapy at deep-inspiration breath hold (DIBH) in the treatment of patients with non-small-cell lung cancer (NSCLC). The relative contributions of tumor immobilization at breath hold (BH) and increased lung volume at deep inspiration (DI) in sparing high-dose lung irradiation (greater than or equal to 20 Gy) were examined. Methods and Materials:Ten consecutive patients undergoing radiotherapy for Stage I-IIIB NSCLC who met the screening criteria were entered on this study. Patients were instructed to BH at DI without the use of external monitors or breath-holding devices (self-gating), Computed tomography (CT) scans of the thorax were performed during free breathing (FB) and DIBH. Fluoroscopy screened for reproducible tumor position throughout DIBH, and determined the maximum superior-inferior (SI) tumor motion during both FB and DIBH. Margins used to define the planning target volume (PTV) from the clinical target volume included 1 cm for setup error and organ motion, plus an additional SI margin for tumor motion, as determined from fluoroscopy. Three conformal treatment plans were then generated for each patient, one from the FB scan with FB PTV margins, a second from the DIBH scan with FB PTV margins, and a third from the DIBH scan with DIBH PTV margins, The percent of total lung volume receiving greater than or equal to 20 Gy (using a prescription dose of 70.9 Gy to isocenter) was determined for each plan. Results:Self-gating at DIBH was possible for 8 of the 10 patients; 2 patients were excluded, because they were not able to perform a reproducible DIBH, For these 8 patients, the median BH time was 23 (range, 19-52) s. The mean percent of total lung volume receiving greater than or equal to 20 Gy under FB conditions (FB scan with FB PTV margins) was 12.8%. With increased lung volume alone (DIBH scan with FB PTV margins), this was reduced to 11.0%, tending toward a significant: decrease in lung irradiation over FB (p = 0.086). With both increased lung volume and tumor immobilization (DIBH scan with DIBH PTV margins), the mean percent lung volume receiving greater than or equal to 20 Gy was further reduced to 8.8%, a significant decrease in lung irradiation compared to FB (p = 0.011). Furthermore, at DIBH, the additional benefit provided by tumor immobilization (i.e., using DIBH instead of FB PTV margins) was also significant (p = 0.006). The relative contributions of tumor immobilization and increased lung volume toward reducing the percent total lung volume receiving greater than or equal to 20 Gy were patient specific; however, all 8 of the patients analyzed showed a dosimetric benefit with this DIBH technique. Conclusion:Compared to FB conditions, at DIBH the mean reduction in percent lung volume receiving greater than or equal to 20 Gy was 14.3% with the increase in lung volume alone, 22.1% with tumor immobilization alone, and 32.5% with the combined effect. The dosimetric benefit seen at DIBH was patient specific, and due to both the increased lung volume seen at DI and the PTV margin reduction seen with tumor immobilization. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:1091 / 1098
页数:8
相关论文
共 50 条
  • [21] Retrospective evaluation of visually monitored deep inspiration breath hold for breast cancer patients using edge detection
    Conroy, L.
    Yeung, R.
    Quirk, S.
    Phan, T.
    Smith, W. L.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 583 - 586
  • [22] Deep inspiration breath hold (DIBH) for cardiac sparing in breast cancer radiotherapy
    Farzin, M.
    Garosi, M.
    Rajabpour, M. Vand
    Gholami, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (01): : 91 - 95
  • [23] The effect of deep inspiration breath-hold on tumour oxygenation
    Aquino-Parsons, C
    Ries, CR
    Minchinton, AI
    D'yachkova, Y
    CLINICAL ONCOLOGY, 2003, 15 (07) : 386 - 393
  • [24] Combining deep-inspiration breath hold and intensity-modulated radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: Dosimetric evaluation using comprehensive plan quality indices
    Choi, Seo Hee
    Park, So Hyun
    Lee, Jason Joon Bock
    Baek, Jong Geol
    Kim, Jin Sung
    Yoon, Hong In
    RADIATION ONCOLOGY, 2019, 14 (1)
  • [25] Cardiac dosimetric evaluation of deep inspiration breath-hold level variances using computed tomography scans generated from deformable image registration displacement vectors
    Harry, Taylor
    Rahn, Doug
    Semenov, Denis
    Gu, Xuejun
    Yashar, Catheryn
    Einck, John
    Jiang, Steve
    Cervino, Laura
    MEDICAL DOSIMETRY, 2016, 41 (01) : 22 - 27
  • [26] Combining deep-inspiration breath hold and intensity-modulated radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: Dosimetric evaluation using comprehensive plan quality indices
    Seo Hee Choi
    So Hyun Park
    Jason Joon Bock Lee
    Jong Geol Baek
    Jin Sung Kim
    Hong In Yoon
    Radiation Oncology, 14
  • [27] Identifying breast cancer patients who gain the most dosimetric benefit from deep inspiration breath hold radiotherapy
    Browne, Patricia
    Beaton, Nakia-Rae
    Sharma, Harish
    Watson, Sharon
    Mai, G. Tao
    Harvey, Jennifer
    Bernard, Anne
    Brown, Elizabeth
    Hargrave, Catriona
    Lehman, Margot
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (04) : 294 - 301
  • [28] Initial end-to-end testing of the ExacTrac dynamic deep inspiration breath hold workflow using a breath hold breast phantom
    Simon K. Goodall
    Peter L. Rampant
    Physical and Engineering Sciences in Medicine, 2023, 46 : 1239 - 1247
  • [29] Heart dose reduction by prone deep inspiration breath hold in left-sided breast irradiation
    Mulliez, Thomas
    Veldeman, Liv
    Speleers, Bruno
    Mahjoubi, Khalil
    Remouchamps, Vincent
    Van Greveling, Annick
    Gilsoul, Monique
    Berwouts, Dieter
    Lievens, Yolande
    Van den Broecke, Rudy
    De Neve, Wilfried
    RADIOTHERAPY AND ONCOLOGY, 2015, 114 (01) : 79 - 84
  • [30] Improved heart, lung and target dose with deep inspiration breath hold in a large clinical series of breast cancer patients
    Nissen, Henrik D.
    Appelt, Ane L.
    RADIOTHERAPY AND ONCOLOGY, 2013, 106 (01) : 28 - 32