Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration

被引:178
|
作者
Barnes, EIA
Murray, BR
Robinson, DM
Underwood, LJ
Hanson, J
Roa, WHY
机构
[1] Cross Canc Inst, Dept Radiat Oncol, Edmonton, AB T6G 1Z2, Canada
[2] Cross Canc Inst, Dept Med Phys, Edmonton, AB T6G 1Z2, Canada
[3] Cross Canc Inst, Dept Epidemiol, Edmonton, AB T6G 1Z2, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 50卷 / 04期
关键词
lung cancer; radiotherapy; respiration gating; self-gating; deep-inspiration breath hold;
D O I
10.1016/S0360-3016(01)01592-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose:To examine the dosimetric benefit of self-gated radiotherapy at deep-inspiration breath hold (DIBH) in the treatment of patients with non-small-cell lung cancer (NSCLC). The relative contributions of tumor immobilization at breath hold (BH) and increased lung volume at deep inspiration (DI) in sparing high-dose lung irradiation (greater than or equal to 20 Gy) were examined. Methods and Materials:Ten consecutive patients undergoing radiotherapy for Stage I-IIIB NSCLC who met the screening criteria were entered on this study. Patients were instructed to BH at DI without the use of external monitors or breath-holding devices (self-gating), Computed tomography (CT) scans of the thorax were performed during free breathing (FB) and DIBH. Fluoroscopy screened for reproducible tumor position throughout DIBH, and determined the maximum superior-inferior (SI) tumor motion during both FB and DIBH. Margins used to define the planning target volume (PTV) from the clinical target volume included 1 cm for setup error and organ motion, plus an additional SI margin for tumor motion, as determined from fluoroscopy. Three conformal treatment plans were then generated for each patient, one from the FB scan with FB PTV margins, a second from the DIBH scan with FB PTV margins, and a third from the DIBH scan with DIBH PTV margins, The percent of total lung volume receiving greater than or equal to 20 Gy (using a prescription dose of 70.9 Gy to isocenter) was determined for each plan. Results:Self-gating at DIBH was possible for 8 of the 10 patients; 2 patients were excluded, because they were not able to perform a reproducible DIBH, For these 8 patients, the median BH time was 23 (range, 19-52) s. The mean percent of total lung volume receiving greater than or equal to 20 Gy under FB conditions (FB scan with FB PTV margins) was 12.8%. With increased lung volume alone (DIBH scan with FB PTV margins), this was reduced to 11.0%, tending toward a significant: decrease in lung irradiation over FB (p = 0.086). With both increased lung volume and tumor immobilization (DIBH scan with DIBH PTV margins), the mean percent lung volume receiving greater than or equal to 20 Gy was further reduced to 8.8%, a significant decrease in lung irradiation compared to FB (p = 0.011). Furthermore, at DIBH, the additional benefit provided by tumor immobilization (i.e., using DIBH instead of FB PTV margins) was also significant (p = 0.006). The relative contributions of tumor immobilization and increased lung volume toward reducing the percent total lung volume receiving greater than or equal to 20 Gy were patient specific; however, all 8 of the patients analyzed showed a dosimetric benefit with this DIBH technique. Conclusion:Compared to FB conditions, at DIBH the mean reduction in percent lung volume receiving greater than or equal to 20 Gy was 14.3% with the increase in lung volume alone, 22.1% with tumor immobilization alone, and 32.5% with the combined effect. The dosimetric benefit seen at DIBH was patient specific, and due to both the increased lung volume seen at DI and the PTV margin reduction seen with tumor immobilization. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:1091 / 1098
页数:8
相关论文
共 50 条
  • [1] Evaluation of the heart and lung dosimetric parameters in deep inspiration breath hold using 3D Slicer
    Eskandari, Azam
    Nasseri, Shahrokh
    Gholamhosseinian, Hamid
    Hosseini, Sare
    Farzaneh, Mohammad Javad Keikhai
    Keramati, Alireza
    Naji, Maryam
    Rostami, Atefeh
    Momennezhad, Mehdi
    RADIATION ONCOLOGY JOURNAL, 2020, 38 (01): : 68 - 76
  • [2] Locally Advanced Lung Cancer Radiotherapy in Deep Inspiration Breath Hold: Dosimetric Benefits from a Prospective Trial
    Josipovic, M.
    Aznar, M.
    Rydhog, J.
    Thomsen, J.
    Damkjaer, S.
    Nygard, L.
    Pohl, M.
    Langer, S.
    Specht, L.
    Persson, G.
    JOURNAL OF THORACIC ONCOLOGY, 2018, 13 (10) : S372 - S373
  • [3] Comparison of deep inspiration breath hold and free breathing technique in left breast cancer irradiation: a dosimetric evaluation in 40 patients
    Aiello, Dario
    Borzi, Giuseppina Rita
    Marino, Lorenza
    Umina, Vincenza
    Di Grazia, Alfio Michelangelo
    JOURNAL OF RADIATION ONCOLOGY, 2019, 8 (01) : 89 - 96
  • [4] Dosimetric evaluation of modern radiation therapy techniques for left breast in deep-inspiration breath-hold
    Koivumakia, Tuomas
    Fogliata, Antonella
    Zeverino, Michele
    Boman, Eeva
    Sierpowska, Joanna
    Moeckli, Raphael
    Vallet, Veronique
    Cozzi, Luca
    Heikkila, Janne
    Vaananen, Anssi
    Vuolukka, Kristiina
    Sillanmaki, Saara
    Seppala, Jan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 82 - 87
  • [5] Dosimetric Considerations in Respiratory-Gated Deep Inspiration Breath-Hold for Left Breast Irradiation
    Walston, Steve
    Quick, Allison M.
    Kuhn, Karla
    Rong, Yi
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (01) : 22 - 32
  • [6] Application and dosimetric comparison of surface-guided deep inspiration breath-hold for lung stereotactic body radiotherapy
    Wang, Jiaxin
    Dong, Tingting
    Meng, Xiangyin
    Li, Wenbo
    Li, Nan
    Wang, Yijun
    Yang, Bo
    Qiu, Jie
    MEDICAL DOSIMETRY, 2024, 49 (04) : 372 - 379
  • [7] Intrafraction tumor motion during deep inspiration breath hold pancreatic cancer treatment
    Zeng, Chuan
    Xiong, Weijun
    Li, Xiang
    Reyngold, Marsha
    Gewanter, Richard M.
    Cuaron, John J.
    Yorke, Ellen D.
    Li, Tianfang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (05): : 37 - 43
  • [8] Dosimetric Evaluation of Deep Inspiration Breath-Hold Technique for Breast Cancer Radiotherapy: A Single-Center Experience
    Temelli, Oztun
    Demirtas, Mehmet
    Ugurlu, Berat Tugrul
    Pepele, Eda Kaya
    Yaprak, Bahaddin
    Gulbas, Hulya
    Eraslan, Fatma Aysun
    Gurocak, Simay
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2020, 35 (04): : 444 - 450
  • [9] Deep Inspiration Breath Hold for Cardiac Sparing No Deep Pockets Required
    Gallant, Fleure
    Jagsi, Reshma
    JACC: CARDIOONCOLOGY, 2024, 6 (04): : 526 - 528
  • [10] A Planning Comparison of IMRT vs. Pencil Beam Scanning for Deep Inspiration Breath Hold Lung Cancers
    Mah, Dennis
    Yorke, Ellen
    Zemanaj, Entela
    Han, Zhiqiang
    Liu, Haoyang
    George, Jobin
    Lambiase, Jason
    Czmielewski, Christian
    Lovelock, D. Michael
    Rimner, Andreas
    Shepherd, Annemarie F.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 26 - 31