Protein phosphorylation reagent concentration curves via Raman Spectroscopy for real-time reaction monitoring in a microfluidic reactor

被引:0
|
作者
Casey, Abigail H. M. [1 ]
Chusan, Nyia E. [2 ]
Campbell, Caroline A. [3 ]
Triplett, Gregory E. [4 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem & Life Sci Engn, Richmond, VA 23220 USA
[2] Virginia Commonwealth Univ, Dept Psychol, Richmond, VA 23220 USA
[3] Virginia Commonwealth Univ, Dept Elect Mech Engn, Richmond, VA 23220 USA
[4] Virginia Commonwealth Univ, Dept Elect Engn, Richmond, VA 23220 USA
来源
BIOSENSING AND NANOMEDICINE XII | 2019年 / 11087卷
关键词
Raman Spectroscopy; protein modification; amino acids; principal component analysis;
D O I
10.1117/12.2531030
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Protein phosphorylation is one of the most prevalent signal transduction mechanisms that occurs within cells. This biochemical reaction follows an enzymatic reaction mechanism where the enzyme or kinase facilitates the transfer of the phosphate group from adenosine triphosphate (ATP) to the substrate protein. By monitoring this reaction in real-time, outside of the cell, the knowledge gained can be applied towards intracellular research in the future. Our goal is to combine microfluidic reactor technology with confocal Raman spectroscopy to investigate biochemical reactions such as protein phosphorylation in order to profile the reaction along the reactor path. By developing an approach that can monitor structural and conformational changes of proteins during biochemical reactions we can provide insight towards signal transduction mechanisms. Our reactor design is based off fluid dynamic principles and continuous reactor design equations. The change in concentration of a reagent during a reaction can be determined by a change in the intensity of its spectral response. The individual reagents for this particular protein phosphorylation reaction include protein kinase A, casein, ATP, a pseudosubstrate, as well as the three phosphorylatable amino acids: L-serine, L-threonine and L-tyrosine. Raman spectroscopy of varying concentrations of each individual reagent will quantify a change in concentration during the reaction. Concentration calibration curves were acquired on solutions inside the microreactor. Lower limit concentration detectability of the Raman instrument was also determined. Full Raman characterization of solid individual reagents was employed as a baseline for comparison of concentration measurements to monitor changes in reagents.
引用
收藏
页数:8
相关论文
共 40 条
  • [21] Monitoring the dynamic process of non-thermal plasma decontaminated water with Raman spectroscopy real-time analysis system
    Lu, Fu
    Ouyang, Wenchong
    He, Yuanyuan
    Wu, Zhengwei
    JOURNAL OF WATER PROCESS ENGINEERING, 2023, 56
  • [22] Predictive modeling in Clostridium acetobutylicum fermentations employing Raman spectroscopy and multivariate data analysis for real-time culture monitoring
    Zu, Theresah N. K.
    Liu, Sanchao
    Germane, Katherine L.
    Servinsky, Matthew D.
    Gerlach, Elliot S.
    Mackie, David M.
    Sund, Christian J.
    SMART BIOMEDICAL AND PHYSIOLOGICAL SENSOR TECHNOLOGY XIII, 2016, 9863
  • [23] Raman-baseddynamic feeding strategies using real-time glucose concentration monitoring system during adalimumab producingCHOcell cultivation
    Domjan, Julia
    Fricska, Annamaria
    Madarasz, Lajos
    Gyurkes, Martin
    Kote, Akos
    Farkas, Attila
    Vass, Panna
    Feher, Csaba
    Horvath, Balazs
    Konczol, Kalman
    Pataki, Hajnalka
    Nagy, Zsombor Kristof
    Marosi, Gyorgy Janos
    Hirsch, Edit
    BIOTECHNOLOGY PROGRESS, 2020, 36 (06)
  • [24] Real-time detection on the expression of soluble protein and inclusion body in the recombinant escherichia coli with laser tweezers raman spectroscopy
    Huang, Shushi
    Lu, Mingqian
    Li, Bing
    Zhou, Bing
    Chen, Limei
    Zhongguo Jiguang/Chinese Journal of Lasers, 2014, 41 (12):
  • [25] Highly sensitive microfluidic sensor using integrated optical fiber and real-time single-cell Raman spectroscopy for diagnosis of pancreatic cancer
    Ni, Renhao
    Ge, Kaixin
    Luo, Yang
    Zhu, Tong
    Hu, Zeming
    Li, Min
    Tao, Pan
    Chi, Jinyi
    Li, Guanron
    Yuan, Haojun
    Pang, Qian
    Gao, Wanlei
    Zhang, Peiqing
    Zhu, Yabin
    BIOSENSORS & BIOELECTRONICS, 2024, 264
  • [26] Real-time assessment of carbon nanotube alignment in a polymer matrix under an applied electric field via polarized Raman spectroscopy
    Chapkin, Wesley A.
    McNerny, Daniel Q.
    Aldridge, Michael F.
    He, Yipeng
    Wang, Weimin
    Kieffer, John
    Taub, Alan I.
    POLYMER TESTING, 2016, 56 : 29 - 35
  • [27] Real-time monitoring of methyl orange degradation in non-thermal plasma by integrating Raman spectroscopy with a hybrid machine learning model
    Zhou, Fan
    Chu, Jiangnan
    Lu, Fu
    Ouyang, Wenchong
    Liu, Qi
    Wu, Zhengwei
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2025, 38
  • [28] Real-Time Quantitative Operando Raman Spectroscopy of a CrOx/Al2O3 Propane Dehydrogenation Catalyst in a Pilot-Scale Reactor
    Sattler, Jesper J. H. B.
    Mens, Ad M.
    Weckhuysen, Bert M.
    CHEMCATCHEM, 2014, 6 (11) : 3139 - 3145
  • [29] Application of Raman spectroscopy to real-time monitoring of CO2 capture at PACT pilot plant; Part 1: Plant operational data
    Akram M.
    Jinadasa M.H.W.N.
    Tait P.
    Lucquiaud M.
    Milkowski K.
    Szuhanszki J.
    Jens K.-J.
    Halstensen M.
    Pourkashanian M.
    International Journal of Greenhouse Gas Control, 2020, 95
  • [30] Real-time monitoring of the column chromatography process of Ginkgo biloba using near-infrared and Raman spectroscopy combined with spectral fusion strategy
    Zhang, Sijie
    Zhang, Sheng
    Gong, Xingchu
    Qu, Haibin
    PROCESS BIOCHEMISTRY, 2024, 145 : 50 - 62