Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids

被引:303
作者
Gao, Wei [1 ,2 ,3 ]
Nyein, Hnin Y. Y. [1 ,2 ,3 ]
Shahpar, Ziba [1 ,2 ]
Fahad, Hossain M. [1 ,2 ]
Chen, Kevin [1 ,2 ,3 ]
Emaminejad, Sam [1 ,2 ,3 ]
Gao, Yuji [1 ,2 ,3 ]
Tai, Li-Chia [1 ,2 ,3 ]
Ota, Hiroki [1 ,2 ,3 ]
Wu, Eric [1 ,2 ]
Bullock, James [1 ,2 ,3 ]
Zeng, Yuping [1 ]
Lien, Der-Hsien [1 ,2 ,3 ]
Javey, Ali [1 ,2 ,3 ]
机构
[1] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Berkeley Sensor & Actuator Ctr, Berkeley, CA 94720 USA
[3] Lawrence Berkeley Natl Lab, Div Mat Sci, Berkeley, CA 94720 USA
来源
ACS SENSORS | 2016年 / 1卷 / 07期
基金
日本学术振兴会;
关键词
flexible electronics; wearable biosensors; heavy metals monitoring; sweat; multiplexed sensing; temperature compensation; ANODIC-STRIPPING VOLTAMMETRY; HUMAN SWEAT; ELECTRONIC SKIN; ELECTROCHEMICAL SENSOR; TRACE-METALS; COPPER; MICROELECTRODE; SPECTROMETRY; PERSPIRATION; EXCRETION;
D O I
10.1021/acssensors.6b00287
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A flexible and wearable microsensor array is described for simultaneous multiplexed monitoring of heavy metals in human body fluids. Zn, Cd, Pb, Cu, and Hg ions are chosen as target analytes for detection via electrochemical square wave anodic stripping voltammetry (SWASV) on Au and Bi microelectrodes. The oxidation peaks of these metals are calibrated and compensated by incorporating a skin temperature sensor. High selectivity, repeatability, and flexibility of the sensor arrays are presented. Human sweat and urine samples are collected for heavy metal analysis, and measured results from the microsensors are validated through inductively coupled plasma mass spectrometry (ICP-MS). Real-time on-body evaluation of heavy metal (e.g., zinc and copper) levels in sweat of human subjects by cycling is performed to examine the change in concentrations with time. This platform is anticipated to provide insightful information about an individual's health state such as heavy metal exposure and aid the related clinical investigations.
引用
收藏
页码:866 / 874
页数:9
相关论文
共 44 条
  • [1] Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
    Bandodkar, Amay J.
    Jia, Wenzhao
    Yardimci, Ceren
    Wang, Xuan
    Ramirez, Julian
    Wang, Joseph
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (01) : 394 - 398
  • [2] Non-invasive wearable electrochemical sensors: a review
    Bandodkar, Amay J.
    Wang, Joseph
    [J]. TRENDS IN BIOTECHNOLOGY, 2014, 32 (07) : 363 - 371
  • [3] Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring
    Bandodkar, Amay J.
    Molinnus, Denise
    Mirza, Omar
    Guinovart, Tomas
    Windmiller, Joshua R.
    Valdes-Ramirez, Gabriela
    Andrade, Francisco J.
    Schoening, Michael J.
    Wang, Joseph
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 54 : 603 - 609
  • [4] Characteristics of subtractive anodic stripping voltammetry of Pb and Cd at silver and gold electrodes
    Bonfil, Y
    Brand, M
    Kirowa-Eisner, E
    [J]. ANALYTICA CHIMICA ACTA, 2002, 464 (01) : 99 - 114
  • [5] Chen K, 2016, ADV MATER, V28, P4397, DOI [10.1002/adma.201504958, 10.1002/adma.201670151]
  • [6] A soft and flexible biosensor using a phospholipid polymer for continuous glucose monitoring
    Chu, MingXing
    Kudo, Hiroyuki
    Shirai, Takayuki
    Miyajima, Kumiko
    Saito, Hirokazu
    Morimoto, Nobuyuki
    Yano, Kazuyoshi
    Iwasaki, Yasuhiko
    Akiyoshi, Kazunari
    Mitsubayashi, Kohji
    [J]. BIOMEDICAL MICRODEVICES, 2009, 11 (04) : 837 - 842
  • [7] COHN JR, 1978, ANN CLIN LAB SCI, V8, P270
  • [8] Development of an anodic stripping voltammetric assay, using a disposable mercury-free screen-printed carbon electrode, for the determination of zinc in human sweat
    Crew, A.
    Cowell, D. C.
    Hart, J. P.
    [J]. TALANTA, 2008, 75 (05) : 1221 - 1226
  • [9] The use of a gold disc microelectrode for the determination of copper in human sweat
    de Souza, Ana P. R.
    Lima, Alex S.
    Salles, Maiara O.
    Nascimento, Angerson N.
    Bertotti, Mauro
    [J]. TALANTA, 2010, 83 (01) : 167 - 170
  • [10] Transparent Triboelectric Nanogenerators and Self-Powered Pressure Sensors Based on Micropatterned Plastic Films
    Fan, Feng-Ru
    Lin, Long
    Zhu, Guang
    Wu, Wenzhuo
    Zhang, Rui
    Wang, Zhong Lin
    [J]. NANO LETTERS, 2012, 12 (06) : 3109 - 3114