Can monodisperse microbubble-based three-dimensional contrast-enhanced ultrasound reduce quantitative heterogeneity? An in vitro study

被引:1
|
作者
Zheng, Qiao [1 ]
Ruan, Si-Min [2 ]
Zhang, Chun-Yang [2 ]
Cao, Zhong [3 ]
Huang, Ze-Rong [2 ]
Guo, Huan-Ling [2 ]
Xie, Xiao-Yan [2 ]
Lu, Ming-De [2 ,4 ]
Wang, Wei [2 ]
Chen, Li-Da [2 ]
机构
[1] Sun Yat Sen Univ, Fetal Med Ctr, Dept Med Ultrason, Affiliated Hosp 1, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Ultras Artificial Intelligence X Lab,Affiliated H, Guangzhou, Peoples R China
[3] Sun Yat Sen Univ, Sch Engn, Dept Biomed Engn, Guangzhou, Peoples R China
[4] Sun Yat Sen Univ, Dept Hepatobiliary Surg, Affiliated Hosp 1, Guangzhou, Peoples R China
来源
ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE | 2022年 / 31卷 / 03期
关键词
ultrasonography; three-dimensional imaging; in vitro technique; contrast agent; MULTICOMPONENT MICROBUBBLES; PERFUSION ANALYSIS; HIGHLY UNIFORM; BLOOD-STREAM; AGENTS; ANGIOGENESIS; DISSOLUTION; VASCULARITY; CERASOME; CEUS;
D O I
10.17219/acem/143585
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background. Heterogeneity within the tumor may cause large heterogeneity in quantitative perfusion parameters. Three-dimensional contrast-enhanced ultrasound (3D-CEUS) can show the spatial relationship of vascular structure after post-acquisition reconstruction and monodisperse bubbles can resonate the ul-trasound pulse, resulting in the increase in sensitivity of CEUS imaging. Objectives. To evaluate whether the combination of 3D-CEUS and monodisperse microbubbles could reduce the heterogeneity of quantitative CEUS. Materials and methods. Three in vitro perfusion models with perfusion volume ratio of 1:2:4 were set up. Both quantitative 2D-CEUS and 3D-CEUS were used to acquire peak intensity (PI) with 2 kinds of ultrasound agents. One was a new kind of monodisperse bubbles produced in this study, named Octafluoropropane-loaded cerasomal microbubbles (OC-MBs), the other was SonoVue (R). The coefficient of variation (CV) was calculated to evaluate the cross-sectional variability. Pearson's correlation analysis was used to assess the cor-relation between weighted PIs (average of PIs of 3 different planes) and perfusion ratios. Results. The average CVs of quantitative 3D-CEUS was slightly lower than that of 2D-CEUS (0.41 +/- 0.17 compared to 0.55 +/- 0.26, p = 0.3592). As for quantitative 3D-CEUS, the PI of the OC-MBs has shown better stability than that of SonoVue (R), but without a significant difference (average CVs: 0.32 +/- 0.19 compared to 0.50 +/- 0.10, p = 0.0711). In the 2D-CEUS condition, the average CVs of OC-MBs group and SonoVue (R) group were 0.68 +/- 0.15 and 0.41 +/- 0.17 (p = 0.2747). As for 3D-CEUS condition, using OC-MBs group and SonoVue (R), the r-values of the weighted PI and perfusion ratio were 0.8685 and 0.5643, respectively, while that of 2D-CEUS condition were 0.7760 and 0.3513, respectively. Conclusions. Our in vitro experiments showed that OC-MBs have the potential in acquiring more stable quantitative CEUS value, as compared to the SonoVue (R) in 3D-CEUS condition. The combination of 3D-CEUS and OC-MBs can reflect perfusion volume more precisely and may be a potential way to reduce quantitative heterogeneity.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 50 条
  • [31] Application of quantitative contrast-enhanced ultrasound for evaluation and guiding biopsy of peripheral pulmonary lesions: a preliminary study
    Wang, Y.
    Xu, Z.
    Huang, H.
    Zhou, X.
    Xian, M.
    CLINICAL RADIOLOGY, 2020, 75 (01) : 79.e19 - 79.e24
  • [32] The application of three-dimensional contrast-enhanced ultrasound to measure volume of affected tissue after HIFU treatment for localized prostate cancer
    Sedelaar, JPM
    Aarnink, RG
    van Leenders, GJLH
    Beerlage, HP
    Debruyne, FMJ
    Wijkstra, H
    de la Rosette, JJMCH
    EUROPEAN UROLOGY, 2000, 37 (05) : 559 - 568
  • [33] Three-Dimensional Contrast-Enhanced Sonography of Vascular Patterns of Focal Liver Tumors: Pilot Study of Visualization Methods
    Luo, Wen
    Numata, Kazushi
    Morimoto, Manabu
    Nozaki, Akito
    Nagano, Yasuhiko
    Sugimori, Kazuya
    Tanaka, Katsuaki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (01) : 165 - 173
  • [34] Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy
    Nemec, Ursula
    Nemec, Stefan F.
    Novotny, Clemens
    Weber, Michael
    Czerny, Christian
    Krestan, Christian R.
    EUROPEAN RADIOLOGY, 2012, 22 (06) : 1357 - 1365
  • [35] Comparative Study of Contrast-Enhanced Ultrasound Qualitative and Quantitative Analysis for Identifying Benign and Malignant Breast Tumor Lumps
    Liu, Jian
    Gao, Yun-Hua
    Li, Ding-Dong
    Gao, Yan-Chun
    Hou, Ling-Mi
    Xie, Ting
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (19) : 8149 - 8153
  • [36] Contrast-enhanced two- and three-dimensional sonography for evaluation of intra-abdominal hemorrhage
    Liu, JB
    Merton, DA
    Goldberg, BB
    Rawool, NM
    Shi, WT
    Forsberg, F
    JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (02) : 161 - 169
  • [37] Three-dimensional ultrasound reconstruction of the pelvicaliceal system: an in-vitro study
    Khurshid R. Ghani
    James Pilcher
    Uday Patel
    David Rowland
    Daruish Nassiri
    Ken Anson
    World Journal of Urology, 2008, 26
  • [38] Three-dimensional ultrasound reconstruction of the pelvicaliceal system: an in-vitro study
    Ghani, Khurshid R.
    Pilcher, James
    Patel, Uday
    Rowland, David
    Nassiri, Daruish
    Anson, Ken
    WORLD JOURNAL OF UROLOGY, 2008, 26 (05) : 493 - 498
  • [39] Application of real-time three-dimensional contrast-enhanced ultrasound using SonoVue for the evaluation of focal liver lesions: a prospective single-center study
    Lu, Ying
    Liu, Baoxian
    Zheng, Yanling
    Luo, Jia
    Zhang, Xiaoer
    Huang, Guangliang
    Xie, Xiaohua
    Ye, Jieyi
    Wang, Wei
    Liu, Xusheng
    Xie, Xiaoyan
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2018, 10 (05): : 1469 - 1480
  • [40] Quantitative contrast-enhanced endoscopic ultrasound in pancreatic ductal adenocarcinoma and pancreatic neuroendocrine tumors: can we predict survival using perfusion parameters? A pilot study
    Constantin, Alina L.
    Cazacu, Irina M.
    Burtea, Daniela Elena
    Harbiyeli, Irina F. Cherciu
    Bejinariu, Nona
    Popescu, Carmen F.
    Serbanescu, Mircea S.
    Tabacelia, Daniela
    Copaescu, Catalin
    Bhutani, Manoop S.
    Stroescu, Cezar
    Saftoiu, Adrian
    MEDICAL ULTRASONOGRAPHY, 2022, 24 (04) : 393 - 398