Can monodisperse microbubble-based three-dimensional contrast-enhanced ultrasound reduce quantitative heterogeneity? An in vitro study

被引:1
|
作者
Zheng, Qiao [1 ]
Ruan, Si-Min [2 ]
Zhang, Chun-Yang [2 ]
Cao, Zhong [3 ]
Huang, Ze-Rong [2 ]
Guo, Huan-Ling [2 ]
Xie, Xiao-Yan [2 ]
Lu, Ming-De [2 ,4 ]
Wang, Wei [2 ]
Chen, Li-Da [2 ]
机构
[1] Sun Yat Sen Univ, Fetal Med Ctr, Dept Med Ultrason, Affiliated Hosp 1, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Ultras Artificial Intelligence X Lab,Affiliated H, Guangzhou, Peoples R China
[3] Sun Yat Sen Univ, Sch Engn, Dept Biomed Engn, Guangzhou, Peoples R China
[4] Sun Yat Sen Univ, Dept Hepatobiliary Surg, Affiliated Hosp 1, Guangzhou, Peoples R China
来源
ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE | 2022年 / 31卷 / 03期
关键词
ultrasonography; three-dimensional imaging; in vitro technique; contrast agent; MULTICOMPONENT MICROBUBBLES; PERFUSION ANALYSIS; HIGHLY UNIFORM; BLOOD-STREAM; AGENTS; ANGIOGENESIS; DISSOLUTION; VASCULARITY; CERASOME; CEUS;
D O I
10.17219/acem/143585
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background. Heterogeneity within the tumor may cause large heterogeneity in quantitative perfusion parameters. Three-dimensional contrast-enhanced ultrasound (3D-CEUS) can show the spatial relationship of vascular structure after post-acquisition reconstruction and monodisperse bubbles can resonate the ul-trasound pulse, resulting in the increase in sensitivity of CEUS imaging. Objectives. To evaluate whether the combination of 3D-CEUS and monodisperse microbubbles could reduce the heterogeneity of quantitative CEUS. Materials and methods. Three in vitro perfusion models with perfusion volume ratio of 1:2:4 were set up. Both quantitative 2D-CEUS and 3D-CEUS were used to acquire peak intensity (PI) with 2 kinds of ultrasound agents. One was a new kind of monodisperse bubbles produced in this study, named Octafluoropropane-loaded cerasomal microbubbles (OC-MBs), the other was SonoVue (R). The coefficient of variation (CV) was calculated to evaluate the cross-sectional variability. Pearson's correlation analysis was used to assess the cor-relation between weighted PIs (average of PIs of 3 different planes) and perfusion ratios. Results. The average CVs of quantitative 3D-CEUS was slightly lower than that of 2D-CEUS (0.41 +/- 0.17 compared to 0.55 +/- 0.26, p = 0.3592). As for quantitative 3D-CEUS, the PI of the OC-MBs has shown better stability than that of SonoVue (R), but without a significant difference (average CVs: 0.32 +/- 0.19 compared to 0.50 +/- 0.10, p = 0.0711). In the 2D-CEUS condition, the average CVs of OC-MBs group and SonoVue (R) group were 0.68 +/- 0.15 and 0.41 +/- 0.17 (p = 0.2747). As for 3D-CEUS condition, using OC-MBs group and SonoVue (R), the r-values of the weighted PI and perfusion ratio were 0.8685 and 0.5643, respectively, while that of 2D-CEUS condition were 0.7760 and 0.3513, respectively. Conclusions. Our in vitro experiments showed that OC-MBs have the potential in acquiring more stable quantitative CEUS value, as compared to the SonoVue (R) in 3D-CEUS condition. The combination of 3D-CEUS and OC-MBs can reflect perfusion volume more precisely and may be a potential way to reduce quantitative heterogeneity.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 50 条
  • [1] Three-dimensional evaluation of microvascular networks using contrast-enhanced ultrasound and microbubble tracking
    Johnson, Kenneth
    Oezdemir, Ipek
    Hoyt, Kenneth
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [2] Three-dimensional contrast-enhanced ultrasound of the liver: Experience of 92 cases
    Xu, Hui-Xiong
    Lu, Ming-De
    Xie, Xiao-Hua
    Xie, Xiao-Yan
    Xu, Zuo-Feng
    Chen, Li-Da
    Liu, Guang-Jian
    Liang, Jin-Yu
    Lin, Man-Xia
    Wang, Zhu
    Huang, Bei
    ULTRASONICS, 2009, 49 (03) : 377 - 385
  • [3] Value of three-dimensional contrast-enhanced power Doppler ultrasound for characterizing adnexal masses
    Huchon, Cyrille
    Metzger, Ulrike
    Bats, Anne-Sophie
    Bensaid, Cherazade
    Chatellier, Gilles
    Azizi, Michel
    Lefrere-Belda, Marie-Aude
    Dujardin, Arnaud
    Bernard, Jean-Pierre
    Lecuru, Fabrice
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2012, 38 (05) : 832 - 840
  • [4] Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases
    El Kaffas, Ahmed
    Sigrist, Rosa Maria Silveira
    Fisher, George
    Bachawal, Sunitha
    Liau, Joy
    Wang, Huaijun
    Karanany, Alexander
    Durot, Isabelle
    Rosenberg, Jarrett
    Hristov, Dimitre
    Willmann, Jurgen K.
    THERANOSTICS, 2017, 7 (15): : 3745 - 3758
  • [5] Feasibility of dynamic three-dimensional contrast-enhanced ultrasound in focal liver lesions: Image quality evaluation and correlation of quantification with two-dimensional contrast-enhanced ultrasound
    Cao, Jiaying
    Dong, Yi
    Fan, Peili
    Mao, Feng
    Wang, Wenping
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2019, 72 (03) : 305 - 316
  • [6] Comparison of Real-Time Two-Dimensional and Three-Dimensional Contrast-Enhanced Ultrasound to Quantify Flow in an In Vitro Model: A Feasibility Study
    Ruan, Si-Min
    Zheng, Qiao
    Wang, Zhu
    Hu, Hang-Tong
    Chen, Li-Da
    Guo, Huan-Ling
    Xie, Xiao-Yan
    Lu, Ming-De
    Li, Wei
    Wang, Wei
    MEDICAL SCIENCE MONITOR, 2019, 25 : 10029 - 10035
  • [7] Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation
    Daeichin, Verya
    van Rooij, Tom
    Skachkov, Ilya
    Ergin, Bulent
    Specht, Patricia A. C.
    Lima, Alexandre
    Ince, Can
    Bosch, Johan G.
    van der Steen, Antonius F. W.
    de Jong, Nico
    Kooiman, Klazina
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (03) : 555 - 567
  • [8] Immediate evaluation and guidance of liver cancer thermal ablation by three-dimensional ultrasound/contrast-enhanced ultrasound fusion imaging
    Xu, Er-Jiao
    Lv, Shu-Min
    Li, Kai
    Long, Ying-Lin
    Zeng, Qing-Jing
    Su, Zhong-Zhen
    Zheng, Rong-Qin
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 34 (06) : 870 - 876
  • [9] Three-dimensional Contrast-enhanced Ultrasound in Response Assessment for Breast Cancer: A Comparison with Dynamic Contrast-enhanced Magnetic Resonance Imaging and Pathology
    Jia, Wan-Ru
    Tang, Lei
    Wang, Deng-Bin
    Chai, Wei-Min
    Fei, Xiao-Chun
    He, Jian-Rong
    Chen, Man
    Wang, Wen-Ping
    SCIENTIFIC REPORTS, 2016, 6
  • [10] Three-dimensional reconstruction of fine vascularity in ultrasound breast imaging using contrast-enhanced spatial compounding:: In vitro analyses
    Hansen, Christian
    Huettebraeuker, Nils
    Wilkening, Wilko
    Ermert, Helmut
    ACADEMIC RADIOLOGY, 2008, 15 (09) : 1155 - 1164