Interobserver and intraobserver variability in the assessment of pulmonary nodule size on CT using film and computer display methods

被引:50
作者
Bogot, NR
Kazerooni, EA
Kelly, AM
Quint, LE
Desjardins, B
Nan, B
机构
[1] Univ Michigan Hosp, Sch Med, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Sch Publ Hlth, Dept Biostat, Ann Arbor, MI 48109 USA
关键词
computed tomography; lung; CT; nodule; image display; quantitative;
D O I
10.1016/j.acra.2005.04.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. A critical element in determining biologic behavior of pulmonary nodules is volume and temporal volume change. We evaluate variability in nodule volume among readers and measuring methods. Materials and Methods. 55 small (<2 cm) lung nodules were measured in long- and short-axis dimensions independently by 4 radiologists, using 3 methods: 1) hard copy, 2) GE Advantage Windows workstation (GE Healthcare, Milwaukee, WI), 3) Siemens IMACS workstation (Siemens Medical Systems, Iselan, NJ). Nodule margin was recorded as smooth, lobulated, or spiculated. Volume was calculated from diameter measurements. Variability in nodule volume was evaluated within each reader, between readers, and across measurement tools. Results. Mean nodule short-axis diameter was 5.3 mm; mean long-axis diameter 7.2 mm. There was statistically significant variation among readers and measurement method for nodule volume. Volume was significantly larger using hardcopy measurements (51.9%-54.1% variation; P <.0001) than either workstation, and not different between workstations. There was greater intracbserver variability in volume using the hard-copy method, and no difference between workstation methods. Volumes based on measurements from one reader were consistently lower than those from other readers (P = <.001,.003, and .02); volume was consistently larger for another reader (P <.0001, .03, and .12). Reader agreement for nodule margin was good to excellent. Conclusion. Considerable interobserver and intraobserver variability in measuring nodules exists using hard-copy and computer tools. Since a small change in diameter indicates a much larger change in volume, this may be significant when using early repeat CT to follow small pulmonary nodules. Computer-aided diagnostic tools that reproducibly measure nodule volume are strongly needed.
引用
收藏
页码:948 / 956
页数:9
相关论文
共 14 条
  • [1] BELPER G, 2003, CANC CONTROL, V10, P306
  • [2] Comparison of unidimensional and bidimensional measurements in metastatic non-small cell lung cancer
    Cortes, J
    Rodriguez, J
    Diaz-Gonzalez, JA
    Garzon, C
    Gurpide, A
    Arbea, L
    Gil-Bazo, I
    Navarro, V
    Cambeiro, M
    Nicolas, A
    Martin-Algarra, S
    Garcia-Foncillas, J
    Calvo, E
    [J]. BRITISH JOURNAL OF CANCER, 2002, 87 (02) : 158 - 160
  • [3] Solitary pulmonary nodules: Part II. Evaluation of the indeterminate nodule
    Erasmus, JJ
    McAdams, HP
    Connolly, JE
    [J]. RADIOGRAPHICS, 2000, 20 (01) : 59 - 66
  • [4] Solitary pulmonary nodules: Part I. Morphologic evaluation for differentiation of benign and malignant lesions
    Erasmus, JJ
    Connolly, JE
    McAdams, HP
    Roggli, VL
    [J]. RADIOGRAPHICS, 2000, 20 (01) : 43 - 58
  • [5] Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: Implications for assessment of tumor response
    Erasmus, JJ
    Gladish, GW
    Broemeling, L
    Sabloff, BS
    Truong, MT
    Herbst, RS
    Munden, RF
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (13) : 2574 - 2582
  • [6] Analysis of interobserver and intraobserver variability in CT tumor measurements
    Hopper, KD
    Kasales, CJ
    VanSlyke, MA
    Schwartz, TA
    TenHave, TR
    Jozefiak, JA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) : 851 - 854
  • [7] Interobserver and intraobserver variations in sonographic measurement of thyroid volume in children
    Özgen, A
    Erol, C
    Kaya, A
    Özmen, MN
    Akata, D
    Akhan, O
    [J]. EUROPEAN JOURNAL OF ENDOCRINOLOGY, 1999, 140 (04) : 328 - 331
  • [8] Radiological measurement of breast cancer metastases to lung and liver: Comparison between WHO (bidimensional) and RECIST (unidimensional) guidelines
    Prasad, SR
    Saini, S
    Sumner, JE
    Hahn, PF
    Sahani, D
    Boland, GW
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) : 380 - 384
  • [9] Evaluation of tumor measurements in oncology: Use of film-based and electronic techniques
    Schwartz, LH
    Ginsberg, MS
    DeCorato, D
    Rothenberg, LN
    Einstein, S
    Kijewski, P
    Panicek, DM
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2000, 18 (10) : 2179 - 2184
  • [10] World Health Organization, 1979, WHO OFFS PUBL