Multi-internal standard calibration applied to inductively coupled plasma optical emission spectrometry

被引:7
作者
Sloop, John T. [1 ]
Donati, George L. [1 ]
Jones, Bradley T. [1 ]
机构
[1] Wake Forest Univ, Dept Chem, Salem Hall,Box 7486, Winston Salem, NC 27109 USA
关键词
Multi-signal methods; Signal bias correction; Internal standardization; Naturally occurring plasma species; ICP-OES; Sample throughput improvement; SIGNAL CORRECTION; SHOOT PROCEDURE; TRACE-ELEMENTS; ICP-MS; SAMPLES; SELECTION; MATRICES;
D O I
10.1016/j.aca.2021.339258
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several species are simultaneously used for internal standardization to improve accuracy in inductively coupled plasma optical emission spectrometry (ICP-OES). In multi-internal standard calibration (MISC), signal ratios between the analyte and each of several internal standard species are used for calibration. A single calibration solution is required, and the MISC graph is built with intensity ratios calculated with analytical signals recorded for the sample (I-A,I-sam) on the y-axis, while those recorded for the calibration standard (IA,std) are plot on the x-axis (i.e. I-A,I-sam/I-IS(i) vs. I-A,I-std/I-IS(i), where I-IS(i) represents the signal intensity for a given internal standard species). Nine analytes (As, Cd, Cr, Cu, Fe, Mg, Mn, Pb and Zn), and two sets of internal standard species (i.e. Bi, Ge, In, Rh, Sc, Te, Tl and Y in solution, or eighteen emission lines from plasma naturally occurring Ar) were evaluated in this proof-of-concept study. The MISC method's efficiency was evaluated by analyte addition and recovery experiments and by analyzing two certified reference materials. Figures of merit for MISC (limit of detection, repeatability and trueness) were comparable to those obtained for the traditional external standard calibration (EC) and internal standard (IS) methods. Different from IS, MISC requires no time-consuming study to identify an ideal internal standard species, and signal biases are minimized by an averaged, more encompassing internal standardization effect. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 31 条
  • [11] Influence of an internal standard in axial ICP OES analysis of trace elements in plant materials
    Drava, Giuliana
    Minganti, Vincenzo
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (02) : 301 - 306
  • [12] Gerlach W., 1929, FDN METHODS CHEM ANA
  • [13] Carbon-related matrix effects in inductively coupled plasma atomic emission spectrometry
    Grindlay, G.
    Gras, L.
    Mora, J.
    de Loos-Vollebregt, M. T. C.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (02) : 234 - 243
  • [14] Selection of internal standards in inductively coupled plasma atomic emission spectrometry by principal component analysis
    Grotti, M
    Magi, E
    Leardi, R
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (03) : 274 - 281
  • [15] Signal correction using molecular species to improve biodiesel analysis by microwave-induced plasma optical emission spectrometry
    Lowery, Kenneth L.
    McSweeney, Tina
    Adhikari, Shiba P.
    Lachgar, Abdessadek
    Donati, George L.
    [J]. MICROCHEMICAL JOURNAL, 2016, 129 : 58 - 62
  • [16] Machado RC, 2020, ANAL METHODS-UK, V12, P39, DOI [10.1039/c9ay02343g, 10.1039/C9AY02343G]
  • [17] Spectral and non-spectral interferences in the determination of selenium by inductively coupled plasma atomic emission spectrometry
    Machat, J
    Otruba, V
    Kanicky, V
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) : 1096 - 1102
  • [18] An ICP index for ICP-MS determinations - new selection rules for internal standards in ICP-MS determinations and carbon enhancement effect
    Narukawa, T.
    Iwai, T.
    Chiba, K.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (08) : 1547 - 1553
  • [19] Matrix effects using an ICP-MS with a single positive ion lens and grounded stop: analyte mass dependent?
    Olesik, John W.
    Jiao, Shi
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (05) : 951 - 966
  • [20] Evaluation of dilute-and-shoot procedure for determination of inorganic impurities in liquid pharmaceutical samples by ICP OES
    Pinheiro, Fernanda C.
    Barros, Ariane, I
    Nobrega, Joaquim A.
    [J]. MICROCHEMICAL JOURNAL, 2019, 146 : 948 - 956