摘要
In this paper, wet gas flow modeling for the straight section of a throat-extended Venturi meter was studied. A static model based on the separated flow theory was presented. Experiments were carried out within static pressure range of 0.26 similar to 0.86 MPa, gas volumetric flowrate range of 80 similar to 120 m(3)/h, water volumetric flowrate range of 0.3 similar to 4.5 m(3)/h and quality range of 0.07 similar to 0.36. It was obtained that the root mean square of the relative errors of the DP over the straight section calculated from the static model was 8.82%.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Wet-Gas Flow Modeling for the Straight Section of Throat-Extended Venturi Meter
    Xu, Lijun
    Zhou, Wanlu
    Li, Xiaomin
    Wang, Minghao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (06) : 2080 - 2087
  • [2] Gas-Liquid Two-Phase Flow Measurement With Throat-Extended Venturi Meter Based on Differential Pressure Ratios and Fluctuations
    Suo, Peng
    Sun, Jiangtao
    Shi, Shiying
    Sun, Shijie
    He, Feng
    Zhang, Xiaokai
    Shen, Mengxian
    Li, Xiaolin
    Li, Jinfei
    Xu, Lijun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [3] Wet gas flow modeling for a vertically mounted Venturi meter
    Xu, Lijun
    Zhou, Wanlu
    Li, Xiaomin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (04)
  • [4] Modeling of wet gas flow in vertically mounted Venturi meter
    Zhou, Wanlu
    Xu, Lijun
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (05): : 1120 - 1125
  • [5] Venturi meter performance in wet gas flow
    DeLeeuw, H
    8TH INTERNATIONAL CONFERENCE ON MULTIPHASE '97 - HOW DEEP? HOW FAR? HOW SOON?, 1997, (24): : 567 - 582
  • [6] Wet gas metering by using a long-throat Venturi meter
    Xu, Lijun
    Li, Hui
    Xu, Jian
    SEVENTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY: SENSORS AND INSTRUMENTS, COMPUTER SIMULATION, AND ARTIFICIAL INTELLIGENCE, 2008, 7127
  • [7] Numerical investigation of wet gas flow in Venturi meter
    He, Denghui
    Bai, Bofeng
    FLOW MEASUREMENT AND INSTRUMENTATION, 2012, 28 : 1 - 6
  • [8] Extended Throat Venturi Based Flow Meter for Optimization of Oil Production Process
    Karimi, Muhammad Akram
    Arsalan, Muhammad
    Shamim, Atif
    IEEE SENSORS JOURNAL, 2021, 21 (16) : 17808 - 17816
  • [9] A Wet Gas Metering System Based on the Extended-Throat Venturi Tube
    Xue, Haobai
    Yu, Peining
    Zhang, Maomao
    Zhang, Haifeng
    Wang, Encheng
    Wu, Guozhu
    Li, Yi
    Zheng, Xiangyuan
    SENSORS, 2021, 21 (06) : 1 - 19
  • [10] Analysis of high pressure tests on wet gas flow metering with a Venturi meter
    Gajan, P.
    Decaudin, Q.
    Couput, J. P.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 44 : 126 - 131