The Effect of Central Corneal Thickness on Tonometry

被引:1
作者
Boehm, A. G. [1 ]
机构
[1] Elblandklinikum Radebeul, Augenklin, D-01445 Radebeul, Germany
关键词
DYNAMIC CONTOUR TONOMETRY; INTRAOCULAR-PRESSURE MEASUREMENT; BIOMECHANICAL PROPERTIES; APPLANATION TONOMETRY; AGE; CURVATURE; ICARE; XL;
D O I
10.1055/s-0029-1246039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Central corneal thickness (CCT) affects IOP measurements and is an independent risk factor for the development of glaucoma. IOP measurements of all common tonometers, such as the Goldmann applanation tonometer, non-contact tonometer and rebound tonometer, are affected by CCT. Nomograms to correct IOP measurements according to CCT have been established. These nomograms lead to a reduction of the measurement error caused by CCT in groups of patients. However, one has to be aware of the fact that, in individuals, the correction of IOP measurements can even increase the deviation of the IOP measurement from the actual IOP. The effect of CCT on dynamic contour tonometry and IOP measured by ORA is negligible. CCT is an important parameter in glaucoma management and needs to be considered when interpreting IOP measurements. This can be done by using nomograms or by implementing CCT in the calculation of the individual target pressure.
引用
收藏
页码:114 / 117
页数:4
相关论文
共 26 条
[1]   Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, Ocular Response Analyzer, and Goldmann tonometry in glaucomatous eyes [J].
Annette, Hager ;
Kristina, Loge ;
Bernd, Schroeder ;
Mark-Oliver, Fuellhas ;
Wolfgang, Wiegand .
JOURNAL OF GLAUCOMA, 2008, 17 (05) :361-365
[2]   Dynamic contour tonometry in comparison to intracameral IOP measurements [J].
Boehm, Andreas G. ;
Weber, Anja ;
Pillunat, Lutz E. ;
Koch, Rainer ;
Spoerl, Eberhard .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (06) :2472-2477
[3]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[4]  
GOLDMANN H, 1957, Ophthalmologica, V134, P221
[5]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
[6]  
GROLMAN B, 1972, AMER J OPT ARCH AM A, V49, P646
[7]   Reduction of intraocular pressure and glaucoma progression - Results from the early manifest glaucoma trial [J].
Heijl, A ;
Leske, MC ;
Bengtsson, B ;
Hyman, L ;
Bengtsson, B ;
Hussein, M .
ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (10) :1268-1279
[8]   Dynamic contour tonometry - Presentation of a new tonometer [J].
Kanngiesser, HE ;
Kniestedt, C ;
Robert, YCA .
JOURNAL OF GLAUCOMA, 2005, 14 (05) :344-350
[9]   Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry [J].
Kohlhaas, M ;
Boehm, AG ;
Spoerl, E ;
Pürsten, A ;
Grein, HJ ;
Pillunat, LE .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (04) :471-476
[10]   Measuring intraocular pressure with the Pulsair 3000 and Rebound tonometers in elderly patients without an anesthetic [J].
Kontiola, A ;
Puska, P .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2004, 242 (01) :3-7