In vivo performance of a laser fluorescence device for the approximal detection of caries in permanent molars

被引:31
作者
Huth, K. C. [1 ]
Lussi, A. [2 ]
Gygax, M. [2 ]
Thum, M. [1 ]
Crispin, A. [3 ]
Paschos, E. [4 ]
Hickel, R. [1 ]
Neuhaus, K. W. [2 ]
机构
[1] Univ Munich, Sch Dent, Dept Restorat Dent Periodont & Paediat Dent, D-80336 Munich, Germany
[2] Univ Bern, Dept Prevent Restorat & Paediat Dent, CH-3012 Bern, Switzerland
[3] Univ Munich, Dept Med Informat Biometry & Epidemiol, D-80336 Munich, Germany
[4] Univ Munich, Dept Orthodont, D-80336 Munich, Germany
关键词
Approximal caries; Caries detection; Laser fluorescence; RCT; OCCLUSAL CARIES; BITEWING RADIOGRAPHS; DIAGNODENT PEN; DENTAL-CARIES; REPRODUCIBILITY; CRITERIA; LESIONS; ICDAS;
D O I
10.1016/j.jdent.2010.09.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of this randomised clinical trial was to investigate if a laser fluorescence device is able to discriminate between sound and carious approximal sites and between enamel and dentinal lesions as well as to find appropriate cut off values Methods One hundred and seventeen sound or uncavitated carious sites in permanent molars were visually and radiographically examined then either opened or not after which their laser fluorescence was measured Forty three lesions were opened the canes removed and the clinically identified canes depths were registered in addition to the radiographical scoring Seventy four sites were radiographically deemed sound or had enamel canes and were not opened Here the radiographical scorings were registered Results Taking the radiographic scoring as gold standard for all investigated approximal sites, sound sites (D-0 n = 40) showed significantly lower laser fluorescence measurements than carious sites (D1-4, n = 77) (Mann-Whitney test P < 0 025) suggesting a cut off at 7 (sensitivinty = 0 68 specificity = 0 7) Comparing measurements of D0-2 (n = 74) and D-3 (4) (n = 43) the results were also different by a statistically significant amount (P < 0 025) and the cut off calculated to be 16 (sensitivity = 06, specificity = 0 84) A fair positive correlation between laser fluorescence values and radiographical scoring was found (rho = +047 P < 0 01) Analysing the 43 opened lesions with their clinically found lesion depths as gold standard there was a fair positive correlation to the laser fluorescence values (rho = +0 34 P = 0 03) and a moderately strong correlation to the radiographic scoring (rho = +067, P < 0 01) Conclusion The device may be an adjunct tool in the approximal detection of canes along with established procedures (C) 2010 Elsevier Ltd All rights reserved
引用
收藏
页码:1019 / 1026
页数:8
相关论文
共 33 条
[1]  
Altman DG, 1991, PRACTICAL STAT MED R
[2]   A systematic review of the performance of a laser fluorescence device for detecting caries [J].
Bader, JD ;
Shugars, DA .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (10) :1413-1426
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   The value of bitewing radiographs in epidemiological caries research: a systematic review of the literature [J].
Bloemendal, E ;
de Vet, HCW ;
Bouter, LM .
JOURNAL OF DENTISTRY, 2004, 32 (04) :255-264
[5]   Prevalence of dental caries in Latvian 11-to 15-year-old children and the enhanced diagnostic yield of temporary tooth separation, FOTI and electronic caries measurement [J].
Deery, C ;
Care, R ;
Chesters, R ;
Huntington, E ;
Stelmachonoka, S ;
Gudkina, Y .
CARIES RESEARCH, 2000, 34 (01) :2-7
[6]   POWER AND SAMPLE-SIZE CALCULATIONS - A REVIEW AND COMPUTER-PROGRAM [J].
DUPONT, WD ;
PLUMMER, WD .
CONTROLLED CLINICAL TRIALS, 1990, 11 (02) :116-128
[7]   Detection, diagnosing, monitoring and logical treatment of occlusal caries in relation to lesion activity and severity: An in vivo examination with histological validation [J].
Ekstrand, KR ;
Ricketts, DNJ ;
Kidd, EAM ;
Qvist, V ;
Schou, S .
CARIES RESEARCH, 1998, 32 (04) :247-254
[8]  
*EUR COMM RAD PROT, 2004, 136 EUR COMM RAD PRO
[9]  
Featherstone J D B, 2004, J Dent Res, V83 Spec No C, pC39
[10]   Influence of different storage methods on laser fluorescence values: A two-year study [J].
Francescut, P ;
Zimmerli, B ;
Lussi, A .
CARIES RESEARCH, 2006, 40 (03) :181-185