Intelligent system for optimal hold-off time selection in an active quench and reset IC

被引:5
作者
Cronin, Donal [1 ]
Morrison, Alan P. [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Elect & Elect Engn, Cork, Ireland
基金
爱尔兰科学基金会;
关键词
afterpulsing; active quench and reset integrated circuit (AQR-1C); autocorrelation; autotuning; Geiger-mode avalanche photodiode (GM-APD); hold-off time; single-photon counting;
D O I
10.1109/JSTQE.2007.902087
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A signal processing circuit using autocorrelation statistics that intelligently selects the optimal hold-off time in an active quench and reset integrated circuit (AQR-IC) is presented. This circuit optimizes the hold-off time to reduce afterpulsing effects in any Geiger-mode avalanche photodiode (GM-APD). The described AQR-IC has a maximum count rate of 20 Mcounts/s, includes a sulmanosecond comparator for quickly detecting incident photons, and incorporates a novel technique, based on silicon delay lines, for selecting 1 of 16 predefined, discrete, hold-off times between 5 and 660 us. The accompanying hold-off time autotuning circuit sets the optimal hold-off time by assigning a 4-b output to the AQR-IC corresponding to the minimization of afterpulse effects in the GM-APD. The configuration sequence completes in a maximum time of 20 s, without operator intervention, and only requires repeating if the GM-APD is changed.
引用
收藏
页码:911 / 918
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 2002, P 28 EUR SOL STAT CI
[2]  
Childers D. G., 1997, PROBABILITY RANDOM P
[3]   Avalanche photodiodes and quenching circuits for single-photon detection [J].
Cova, S ;
Ghioni, M ;
Lacaita, A ;
Samori, C ;
Zappa, F .
APPLIED OPTICS, 1996, 35 (12) :1956-1976
[4]   TRAPPING PHENOMENA IN AVALANCHE PHOTODIODES ON NANOSECOND SCALE [J].
COVA, S ;
LACAITA, A ;
RIPAMONTI, G .
IEEE ELECTRON DEVICE LETTERS, 1991, 12 (12) :685-687
[5]  
Cronin D, 2004, 2004 HIGH FREQUENCY POSTGRADUATE STUDENT COLLOQUIUM, P9
[6]  
CRONIN D, 2006, P SPIE PHOT W C JAN, V6124, P224
[7]  
CRONIN D, 2005, P IEEE LEOS C OCT, P957
[8]  
Enderlein J, 1998, BIOIMAGING, V6, P3, DOI 10.1002/1361-6374(199803)6:1<3::AID-BIO2>3.0.CO
[9]  
2-M
[10]  
HAAG M, AUTOCORRELATION RAND