On-line preconcentration and in situ photochemical vapor generation in coiled reactor for speciation analysis of mercury and methylmercury by atomic fluorescence spectrometry

被引:62
作者
Gao, Ying [1 ]
Yang, Wulin [2 ]
Zheng, Chengbin [1 ]
Hou, Xiandeng [1 ,2 ]
Wu, Li [2 ]
机构
[1] Sichuan Univ, Coll Chem, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, Analyt & Testing Ctr, Chengdu 610064, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
SOLID-PHASE EXTRACTION; NATURAL-WATERS; SORPTION PRECONCENTRATION; ABSORPTION-SPECTROMETRY; INORGANIC SELENIUM; UV-IRRADIATION; LIQUID-CHROMATOGRAPHY; SAMPLE INTRODUCTION; BIOLOGICAL SAMPLES; KNOTTED REACTOR;
D O I
10.1039/c0ja00137f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line preconcentration and in situ photochemical vapor generation in a coiled reactor was proposed for speciation analysis of ultratrace mercury and methylmercury (Hg2+ and MeHg+) by using atomic fluorescence spectrometric detection. Diethyldithiocarbamate (DDTC) served here not only as a chelating reagent to form hydrophobic compound of mercury for on-line preconcentration but also as a reductant for in situ photochemical vapor generation and desorption of mercury from the coiled reactor. Optimum conditions for on-line preconcentration and in situ photochemical vapor generation, as well as potential speciation analysis of Hg2+ and MeHg+, were carefully investigated. Limit of detection (LOD, 3 sigma) of 0.004 mu g L-1 or 0.0008 mu g L-1 for Hg2+ was obtained based on 40 s or 200 s of sample loading time, respectively, and it can be further improved by prolonging the sample loading time when necessary. The linear working range was in the range of 0.02-8 mu g L-1 with 40 s sample loading time. A precision of 4.5% RSD was achieved with mercury concentration of 2 mu g L-1. The proposed method can be applied for rapid speciation analysis of Hg2+ and MeHg+ by controlling the desorption and photochemical vapor generation conditions. The accuracy of the proposed method was evaluated by analysis of certified reference materials including water samples (GBW 080392 and GBW 080393), fish muscle (GBW 10029), and human hair (GBW 09101b), as well as National Research Council Canada DORM-2 fish muscle tissue. This is a simple, ultrasensitive and relatively green method for the determination of mercury and methylmercury.
引用
收藏
页码:126 / 132
页数:7
相关论文
共 42 条
[21]   UV-induced carbonyl generation with formic acid for sensitive determination of nickel by atomic fluorescence spectrometry [J].
Liu, Liwei ;
Deng, Hao ;
Wu, Li ;
Zheng, Chengbin ;
Hou, Xiandeng .
TALANTA, 2010, 80 (03) :1239-1244
[22]   Effect of chemical speciation on toxicity of mercury to Escherichia coli biofilms and planktonic cells [J].
Najera, I ;
Lin, CC ;
Kohbodi, GA ;
Jay, JA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (09) :3116-3120
[23]   Evaluation of different sample pre-treatment and extraction procedures for mercury speciation in fish samples [J].
Ortiz, AIC ;
Albarrán, YM ;
Rica, CC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (12) :1595-1601
[24]   Preservation and storage techniques for low-level aqueous mercury speciation [J].
Parker, JL ;
Bloom, NS .
SCIENCE OF THE TOTAL ENVIRONMENT, 2005, 337 (1-3) :253-263
[25]   Determination of trace metal fractionation in aqueous solutions using a solid phase extraction flow injection system on-line coupled to ICP-AES [J].
Puls, Christoph ;
Limbeck, Andreas .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) :1434-1440
[26]   Determination of methylmercury, ethylmercury, and inorganic mercury in mouse tissues, following administration of thimerosal, by species-specific isotope dilution GC-inductively coupled plasma-MS [J].
Qvarnström, J ;
Lambertsson, L ;
Havarinasab, S ;
Hultman, P ;
Frech, W .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4120-4124
[27]   Modern extraction techniques [J].
Raynie, Douglas E. .
ANALYTICAL CHEMISTRY, 2006, 78 (12) :3997-4003
[28]   Determination of total and inorganic mercury in whole blood by cold vapor inductively coupled plasma mass spectrometry (CV ICP-MS) with alkaline sample preparation [J].
Rodrigues, Jairo L. ;
Torres, Daiane P. ;
de Oliveira Souza, Vanessa C. ;
Batista, Bruno L. ;
de Souza, Samuel S. ;
Curtius, Adilson J. ;
Barbosa, Fernando, Jr. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) :1414-1420
[29]   An Automated Hydride Generation Interface to ICPMS for Measuring Total Arsenic in Environmental Samples [J].
Sengupta, Mrinal K. ;
Dasgupta, Purnendu K. .
ANALYTICAL CHEMISTRY, 2009, 81 (23) :9737-9743
[30]   On-line HPLC-UV/nano-TiO2-ICPMS system for the determination of inorganic selenium species [J].
Sun, YC ;
Chang, YC ;
Su, CK .
ANALYTICAL CHEMISTRY, 2006, 78 (08) :2640-2645