The response of a radiophotoluminescent glass dosimeter in megavoltage photon and electron beams

被引:17
作者
Araki, Fujio [1 ]
Ohno, Takeshi [1 ]
机构
[1] Kumamoto Univ, Fac Life Sci, Dept Hlth Sci, Chuo Ku, Kumamoto 8620976, Japan
关键词
radiophotoluminescent glass dosimeter; beam quality dependence; Monte Carlo simulation; Burlin's general cavity theory; MONTE-CARLO SIMULATIONS; QUALITY DEPENDENCE; ROD DETECTOR; LIF; TLD;
D O I
10.1118/1.4901639
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigated the response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon and electron beams. Methods: The RGD response was compared with ion chamber measurements for 4-18 MV photons and 6-20 MeV electrons in plastic water phantoms. The response was also calculated via Monte Carlo (MC) simulations with EGSnrc/egs_chamber and Cavity user-codes, respectively. In addition, the response of the RGD cavity was analyzed as a function of field sizes and depths according to Burlin's general cavity theory. The perturbation correction factor, P-Q, in the RGD cavity was also estimated from MC simulations for photon and electron beams. Results: The calculated and measured RGD energy response at reference conditions with a 10 x 10 cm(2) field and 10 cm depth in photons was lower by up to 2.5% with increasing energy. The variation in RGD response in the field size range of 5 x 5 cm(2) to 20 x 20 cm(2) was 3.9% and 0.7%, at 10 cm depth for 4 and 18 MV, respectively. The depth dependence of the RGD response was constant within 1% for energies above 6 MV but it increased by 2.6% and 1.6% for a large (20 x 20 cm(2)) field at 4 and 6 MV, respectively. The dose contributions from photon interactions (1 - d) in the RGD cavity, according to Burlin's cavity theory, decreased with increasing energy and decreasing field size. The variation in (1 - d) between field sizes became larger with increasing depth for the lower energies of 4 and 6 MV. P-Q for the RGD cavity was almost constant between 0.96 and 0.97 at 10 MV energies and above. Meanwhile, P-Q depends strongly on field size and depth for 4 and 6 MV photons. In electron beams, the RGD response at a reference depth, d(ref), varied by less than 1% over the electron energy range but was on average 4% lower than the response for 6 MV photons. Conclusions: The RGD response for photon beams depends on both (1 - d) and perturbation effects in the RGD cavity. Therefore, it is difficult to predict the energy dependence of RGD response by Burlin's theory and it is recommended to directly measure RGD response or use the MC-calculated RGD response, regarding the practical use. The response for electron beams decreased rapidly at a depth beyond d(ref) for lower mean electron energies <3 MeV and in contrast P-Q increased. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:8
相关论文
共 30 条
[1]   Application of a radiophotoluminescent glass plate dosimeter for small field dosimetry [J].
Aaki, F ;
Ishidoya, T ;
Ikegami, T ;
Moribe, N ;
Yamashita, Y .
MEDICAL PHYSICS, 2005, 32 (06) :1548-1554
[2]  
[Anonymous], PIRS898 NAT RES COUN
[3]   Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams from a linear accelerator and Cyber-Knife [J].
Araki, F ;
Moribe, N ;
Shimonobou, T ;
Yamashita, Y .
MEDICAL PHYSICS, 2004, 31 (07) :1980-1986
[4]   Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector [J].
Araki, F ;
Ikegami, T ;
Ishidoya, T ;
Kubo, HD .
MEDICAL PHYSICS, 2003, 30 (08) :1976-1981
[5]  
Araki Fujio, 2005, Igaku Butsuri, V25, P24
[6]  
*AS TECHN GLASS CO, 2000, EXPL MAT RPL GLASS D
[7]   A GENERAL THEORY OF CAVITY IONISATION [J].
BURLIN, TE .
BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (466) :727-&
[8]   STOPPING-POWER AND MASS ENERGY-ABSORPTION COEFFICIENT RATIOS FOR SOLID WATER [J].
HO, AK ;
PALIWAL, BR .
MEDICAL PHYSICS, 1986, 13 (03) :403-404
[9]   Application of a newly developed photoluminescence glass dosimeter for measuring the absorbed dose in individual mice exposed to low-dose rate 137Cs γ-rays [J].
Hoshi, Y ;
Nomura, T ;
Oda, T ;
Iwasaki, T ;
Fujita, K ;
Ishikawa, T ;
Kato, A ;
Ikegami, T ;
Sakai, K ;
Tanooka, H ;
Yamada, T .
JOURNAL OF RADIATION RESEARCH, 2000, 41 (02) :129-137
[10]  
International Atomic Energy Agency, 2000, IAEA TRS-398