Control of suture hole bleeding after aortic valve replacement by application of BioGlue™ during circulatory arrest

被引:8
作者
Dunst, KM [1 ]
Antretter, H [1 ]
Bonatti, J [1 ]
机构
[1] Med Univ Innsbruck, Dept Cardiac Surg, A-6020 Innsbruck, Austria
关键词
suture hole bleeding; aortic surgery; Bioglue (TM);
D O I
10.1536/ihj.46.175
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bleeding from suture holes ill aortic valve replacement (AVR) may represent a difficult problem especially if the aortic wall is friable. We describe a case ill which suture hole bleeding after AVR was present at the posterior aortic wall close to the pulmonary artery. Following several attempts to suture the leak using felt pledget armed prolene sutures. deep hypothermic circulatory arrest was induced and BioGlue (TM) ill combination with Tabotamp (TM) was applied for successful sealing of the bleeding source.
引用
收藏
页码:175 / 179
页数:5
相关论文
共 13 条
[1]  
Bachet J, 1998, Chirurgie, V123, P229, DOI 10.1016/S0001-4001(98)80114-1
[2]   Late complications of tissue glues in aortic surgery [J].
Bingley, JA ;
Gardner, MAH ;
Stafford, EG ;
Mau, TK ;
Pohlner, PG ;
Tam, RKW ;
Jalali, H ;
Tesar, PJ ;
O'Brien, MF .
ANNALS OF THORACIC SURGERY, 2000, 69 (06) :1764-1768
[3]   CONTROL OF NEEDLE HOLE BLEEDING WITH ETHYL-CYANOACRYLATE GLUE (KRAZY GLUE) [J].
CITRIN, P ;
DOSCHER, W ;
WISE, L ;
MARGOLIS, IB .
JOURNAL OF VASCULAR SURGERY, 1985, 2 (03) :488-490
[4]   Prospective randomized study of a protein-based tissue adhesive used as a hemostatic and structural adjunct in cardiac and vascular anastomotic repair procedures [J].
Coselli, JS ;
Bavaria, JE ;
Fehrenbacher, J ;
Stowe, CL ;
Macheers, SK ;
Gundry, SR .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2003, 197 (02) :243-252
[5]  
Coselli JS., 2000, OPERATIVE TECH THORA, V5, P259, DOI 10.1053/otct.2000.21802
[6]  
Czerny M, 2000, J CARDIOVASC SURG, V41, P553
[7]  
Downing SW, 2003, ANN THORAC SURG, V75, P1063, DOI 10.1016/S0003-4975(02)03473-2
[8]  
Erasmi AW, 2002, ANN THORAC SURG, V73, P1025, DOI 10.1016/S0003-4975(01)03524-X
[9]   Sutureless coronary artery bypass with biologic glued anastomoses: Preliminary in vivo and in vitro results [J].
Gundry, SR ;
Black, K ;
Izutani, H .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 120 (03) :473-477
[10]   HEMOSTATIC EFFECTS OF MICROFIBRILLAR COLLAGEN HEMOSTAT (MCH) IN EXPERIMENTAL COAGULOPATHY MODEL AND ITS MECHANISM OF HEMOSTASIS [J].
HATSUOKA, M ;
SEIKI, M ;
SASAKI, K ;
KASHII, A .
THROMBOSIS RESEARCH, 1986, 42 (03) :407-412