The use of acetabular screws in total hip arthroplasty and its influence on wear and periacetabular osteolysis in the long-term follow-up

被引:9
作者
Brodt, Steffen [1 ]
Bischoff, Kathleen [1 ]
Schulze, Marcel [1 ]
Nowack, Dimitri [1 ]
Roth, Andreas [2 ]
Matziolis, Georg [1 ]
机构
[1] Jena Univ Hosp, Dept Orthoped, Campus Eisenberg,Klosterlausnitzer Str 81, D-07607 Eisenberg, Germany
[2] Univ Hosp Leipzig, Dept Endoprosthesis Orthoped, Clin Orthoped Traumatol & Plast Surg, Liebigstr 20, D-04103 Leipzig, Germany
关键词
Hip; THA; Wear; Osteolysis; Screws; CROSS-LINKED POLYETHYLENE; INITIAL STABILITY; CEMENTLESS CUPS; FIXATION; ECCENTRICITY; SOCKETS;
D O I
10.1007/s00264-021-05219-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The cementless implantation of hip replacement cups may be performed with and without the additional use of acetabular screws. If the surgeon uses screws or not depends on variable factors. In general, the use of screws is intended to increase the primary stability of the cup. Whether screws increase the initial stability of the cup construct, or even reduce it in part, is the subject of considerable debate in the literature. It is also unclear whether the additional screws lead to increased wear or increased periacetabular osteolysis over the long-term course. Methods Two hundred eleven patients from a previous study with a minimum follow-up of 10.7 years were included. Of these, 68 patients with 82 total hip arthroplasties (THA) were given clinical and radiological follow-up examinations. Of these, 52 had been fitted without screws and 30 with screws. On the basis of radiographs, annual wear and osteolysis were quantified. The clinical results were recorded by means of VAS, HHS, and WOMAC scores. Results Significantly more periacetabular osteolysis was found if additive acetabular screws had been used. No difference was found in relation to the volumetric wear per year. Likewise, no difference was found with regard to the clinical scores. Conclusions The use of additive acetabular screws leads to increased osteolysis in the periacetabular bone stock. Insofar as the primary stability of the cementless cup construct allows it, no additional acetabular screws should be used.
引用
收藏
页码:717 / 722
页数:6
相关论文
共 28 条
[11]   Effects of screw eccentricity on the initial stability of the acetabular cup [J].
Hsu, Jui-Ting ;
Chang, Chih-Han ;
An, Kai-Nan ;
Zobitz, Mark E. ;
Phimolsarnti, Rapin ;
Hugate, Ronald R. ;
Lai, Kuo-An .
INTERNATIONAL ORTHOPAEDICS, 2007, 31 (04) :451-455
[12]   The number of screws, bone quality, coefficient affect acetabular cup and friction stability [J].
Hsu, Jui-Ting ;
Chang, Chih-Han ;
Huang, Heng-Li ;
Zobitz, Mark E. ;
Chen, Weng-Pin ;
Lai, Kuo-An ;
An, Kai-Nan .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) :1089-1095
[13]   Cementless Acetabular Fixation With and Without Screws Analysis of Stability and Migration [J].
Iorio, Richard ;
Puskas, Brian ;
Healy, William L. ;
Tilzey, John F. ;
Specht, Lawrence M. ;
Thompson, Michael S. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (02) :309-313
[14]   The initial fixation of the press-fit acetabular shell - clinical observation and experimental study [J].
Kaneko, K ;
Inoue, Y ;
Yanagihara, Y ;
Uta, S ;
Mogami, A ;
Iwase, H .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (5-6) :323-325
[15]   Wear and osteolysis outcomes for highly cross-linked polyethylene in primary total hip arthroplasty compared with conventional polyethylene: a 15-to 18-year single-centre follow-up study [J].
Moon, Nam Hoon ;
Shin, Won Chul ;
Uk, Min ;
Kang, Suk-Woong ;
Lee, Sang-Min ;
Suh, Kuen Tak .
HIP INTERNATIONAL, 2021, 31 (04) :526-532
[16]   Cementless acetabular component inserted without screws - the effect of immediate weight-bearing [J].
Ng, F. Y. ;
Zhu, Y. ;
Chiu, K. Y. .
INTERNATIONAL ORTHOPAEDICS, 2007, 31 (03) :293-296
[17]   Acetabular screws do not improve early revision rates in primary total hip arthroplasty. An instrumented registry analysis [J].
Nugent, Mary ;
Campbell, David G. ;
Lewis, Peter L. ;
Cuthbert, Alana R. ;
Solomon, Lucien B. .
INTERNATIONAL ORTHOPAEDICS, 2021, 45 (03) :593-604
[18]   A cementless, elastic press-fit socket with and without screws A 2-year randomized controlled radiostereometric analysis of 37 hips [J].
Pakvis, Dean ;
Luites, Joan ;
van Hellemondt, Gijs ;
Spruit, Maarten .
ACTA ORTHOPAEDICA, 2012, 83 (05) :481-487
[19]  
PILLIAR RM, 1987, J BIOMED MATER RES-A, V21, P1
[20]  
Ries MD, 1997, CLIN ORTHOP RELAT R, P276