A three-dimensional thermal model of the human cochlea for magnetic cochlear implant surgery

被引:1
|
作者
Esmailie, Fateme [1 ]
Francoeur, Mathieu [1 ]
Ameel, Tim [1 ]
机构
[1] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
Thermal trauma; Cochlear implant; Magnetic insertion; TEMPORAL BONE; INSERTION; TEMPERATURE; DIMENSIONS; THICKNESS; GLYCEROL; TEXTURE; HEARING; FORCE;
D O I
10.1016/j.ijheatmasstransfer.2021.121553
中图分类号
O414.1 [热力学];
学科分类号
摘要
In traditional cochlear implant surgery, physical trauma may occur during electrode array insertion. Magnetic guidance of the electrode array has been proposed to mitigate this medical complication. After insertion, the guiding magnet attached to the tip of the electrode array must be detached via a heating process and removed. This heating process may, however, cause thermal trauma within the cochlea. In this study, a validated three-dimensional finite element heat transfer model of the human cochlea is applied to perform an intracochlear thermal analysis necessary to ensure the safety of the magnet removal phase. Specifically, the maximum safe input power density to detach the magnet is determined as a function of the boundary conditions, heating duration, cochlea size, implant electrode array radius and insertion depth, magnet size, and cochlear fluid. A dimensional analysis and numerical simulations reveal that the maximum safe input power density increases with increasing cochlea size and the radius of the electrode array, whereas it decreases with increasing electrode array insertion depth and magnet size. The best cochlear fluids from the thermal perspective are perilymph and a soap solution. Even for the worst case scenario in which the cochlear walls are assumed to be adiabatic except at the round window, the maximum safe input power density is larger than that required to melt 1 mm(3) of paraffin bonding the magnet to the implant electrode array. By combining the outcome of this work with other aspects of the design of the magnetic insertion process, namely the magnetic guidance procedure and medical requirements, it will be possible to implement a thermally safe patient-specific surgical procedure. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Three-dimensional models of cochlear implants: A review of their development and how they could support management and maintenance of cochlear implant performance
    Hanekom, Tania
    Hanekom, Johan J.
    NETWORK-COMPUTATION IN NEURAL SYSTEMS, 2016, 27 (2-3) : 67 - 106
  • [42] A model of the electrically excited human cochlear neuron. II. Influence of the three-dimensional cochlear structure on neural excitability
    Rattay, F
    Leao, RN
    Felix, H
    HEARING RESEARCH, 2001, 153 (1-2) : 64 - 79
  • [43] Cochlear Implant Insertion Forces in Microdissected Human Cochlea to Evaluate a Prototype Array
    Yann Nguyen
    Miroir, Mathieu
    Kazmitcheff, Guillaume
    Sutter, Jasmine
    Bensidhoum, Morad
    Ferrary, Evelyne
    Sterkers, Olivier
    Grayeli, Alexis Bozorg
    AUDIOLOGY AND NEURO-OTOLOGY, 2012, 17 (05) : 290 - 298
  • [44] Miniature cochlea: a study of radiological measurements and its implications during the cochlear implant surgery
    Tarabishi M.N.
    Sarwat A.A.
    Kamal Rabie H.M.
    Nada I.M.
    Hakim E.K.
    Hasaballah M.S.
    El-Sharnouby M.M.
    Aziz T.T.A.
    The Egyptian Journal of Otolaryngology, 2016, 32 (3) : 170 - 177
  • [45] Ossified cochlea in cochlear implant surgery. Radiographic imaging, surgical technique and results
    RamosMacias, A
    CuyasTorres, JM
    COCHLEAR IMPLANTS, 1996, : 313 - 316
  • [46] Three-dimensional reconstruction of tectorial membrane motion in the cochlea
    Dong, W
    Cooper, NP
    BRITISH JOURNAL OF AUDIOLOGY, 2000, 34 (02): : 88 - 88
  • [47] A new method for three-dimensional immunofluorescence study of the cochlea
    Brody, Kate M.
    Hampson, Amy J.
    Cho, Hyun-jung
    Johnson, Prudence
    O'Leary, Stephen J.
    HEARING RESEARCH, 2020, 392
  • [48] Three-Dimensional Navigation in Implant Dentistry
    Marquardt, Pascal
    Witkowski, Siegbert
    Strub, Joerg
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2007, 2 (01): : 80 - 98
  • [49] Three-dimensional model printing for surgery on arteriovenous malformations
    Shah, Abhidha
    Jankharia, Bhavin
    Goel, Atul
    NEUROLOGY INDIA, 2017, 65 (06) : 1350 - 1354
  • [50] A three-dimensional model of the human pulmonary acinus
    Kitaoka, H
    Tamura, S
    Takaki, R
    JOURNAL OF APPLIED PHYSIOLOGY, 2000, 88 (06) : 2260 - 2268