This paper reports a new X-ray beam geometry to acquire two separated polychromatic X-rays as well as two separated fan beams using parallel different filters built in a single collimator. This newly designed X-ray spectrum was generated by a single X-ray shot but had the effect of double X-ray exposure. The two separated filters were used side by side. The first filter for the low energy spectra was 0.5 mm thick erbium and the second filter for the high energy spectra was composed of two layers of a 0.8 mm of copper and 0.4mmof rhodium. This combination of filters showed excellent performance of X-ray beam hardening regardless of the bone thickness in the soft tissue under DXA conditions.
引用
收藏
页码:2155 / 2158
页数:4
相关论文
共 50 条
  • [41] Dual-energy x-ray absorptiometry (DXA) scan interpretation: Looking beyond the numbers
    Theodorou, DJ
    Theodorou, SJ
    Sartoris, DJ
    Deftos, LJ
    Resnick, D
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : S145 - S146
  • [42] Bone age assessment by dual-energy X-ray absorptiometry in children: an alternative for X-ray?
    Heppe, D. H. M.
    Taal, H. R.
    Ernst, G. D. S.
    Van den Akker, E. L. T.
    Lequin, M. M. H.
    Hokken-Koelega, A. C. S.
    Geelhoed, J. J. M.
    Jaddoe, V. W. V.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1010): : 114 - 120
  • [43] Dual-energy X-ray absorptiometry of the pig: Protocol development and evaluation
    Nielsen, DH
    McEvoy, FJ
    Poulsen, HL
    Madsen, MT
    Buelund, LE
    Svalastoga, E
    MEAT SCIENCE, 2004, 68 (02) : 235 - 241
  • [44] Dual-Energy X-Ray Absorptiometry in the Evaluation of Abdominal Aortic Calcifications
    Bazzocchi, Alberto
    Ciccarese, Federica
    Diano, Danila
    Spinnato, Paolo
    Albisinni, Ugo
    Rossi, Cristina
    Guglielmi, Giuseppe
    JOURNAL OF CLINICAL DENSITOMETRY, 2012, 15 (02) : 198 - 204
  • [45] CONFRONTING MORPHOMETRIC X-RAY RADIOGRAPHY AND DUAL-ENERGY X-RAY ABSORPTIOMETRY IN THE DIAGNOSIS OF OSTEOPOROSIS
    Stefani, A.
    Desideri, G.
    Camerota, A.
    Carucci, A. C.
    Caporuscio, S.
    Canzoni, M.
    Raffaele, A.
    Sorgi, M. L.
    OSTEOPOROSIS INTERNATIONAL, 2017, 28 : S389 - S389
  • [46] Body composition measured by dual energy X-ray absorptiometry (DXA).
    Boileau, R
    Slaughter, M
    Stillman, R
    Christ, G
    Dykstra, R
    Geeseman, R
    FarrellLee, K
    Novitsky, S
    Pritschet, B
    FASEB JOURNAL, 1996, 10 (03): : 1119 - 1119
  • [47] Movement artifact and dual x-ray absorptiometry (DXA).
    Cawkwell, GD
    ARTHRITIS AND RHEUMATISM, 1996, 39 (09): : 368 - 368
  • [48] Absorbed dose measurements in dual energy X-ray absorptiometry (DXA)
    Bezakova, E
    Collins, PJ
    Beddoe, AH
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : 172 - 179
  • [49] Dual energy X-ray absorptiometry
    Winzenberg, Tania
    Jones, Graeme
    AUSTRALIAN FAMILY PHYSICIAN, 2011, 40 (1-2) : 43 - 44
  • [50] Lean mass reference curves in adolescents using dual-energy x-ray absorptiometry (DXA)
    Ripka, Wagner Luis
    Orsso, Camila E.
    Haqq, Andrea M.
    Luz, Thais Gretis
    Prado, Carla M.
    Ulbricht, Leandra
    PLOS ONE, 2020, 15 (02):