X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)

被引:1
|
作者
Kim, Kwang Hyun [1 ]
机构
[1] Jungwon Univ, Dept Med Engn, Goesan Gun, Chungcheongbuk, South Korea
关键词
Dual-energy X-ray; DXA; K-edge filter; X-ray beam hardening; RADIOGRAPHY; TOMOGRAPHY;
D O I
10.1109/TNS.2010.2050335
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports a new X-ray beam geometry to acquire two separated polychromatic X-rays as well as two separated fan beams using parallel different filters built in a single collimator. This newly designed X-ray spectrum was generated by a single X-ray shot but had the effect of double X-ray exposure. The two separated filters were used side by side. The first filter for the low energy spectra was 0.5 mm thick erbium and the second filter for the high energy spectra was composed of two layers of a 0.8 mm of copper and 0.4mmof rhodium. This combination of filters showed excellent performance of X-ray beam hardening regardless of the bone thickness in the soft tissue under DXA conditions.
引用
收藏
页码:2155 / 2158
页数:4
相关论文
共 50 条
  • [1] Dual-energy X-ray Absorptiometry
    Jain, Rajesh K.
    Vokes, Tamara
    JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (03) : 291 - 303
  • [2] Osteosarcopenia-The Role of Dual-Energy X-ray Absorptiometry (DXA) in Diagnostics
    Gonera-Furman, Aleksandra
    Bolanowski, Marek
    Jedrzejuk, Diana
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (09)
  • [3] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [4] Fundamentals and pitfalls of bone densitometry using dual-energy X-ray absorptiometry (DXA)
    Nelson B. Watts
    Osteoporosis International, 2004, 15 : 847 - 854
  • [5] Detection of glass contamination in horticultural peat with dual-energy X-ray absorptiometry (DXA)
    Ayalew, G
    Holden, NM
    Grace, PA
    Ward, SM
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2004, 42 (01) : 1 - 17
  • [6] Dual-energy X-ray Absorptiometry Quality Matters
    Krueger, Diane
    Binkley, Neil
    Morgan, Sarah
    JOURNAL OF CLINICAL DENSITOMETRY, 2018, 21 (02) : 155 - 156
  • [7] Dual-energy X-ray Absorptiometry Does Not Represent Bone Structure in Patients with Osteoporosis A Comparison of Lumbar Dual-Energy X-Ray Absorptiometry with Vertebral Biopsies
    Pumberger, Matthias
    Palmowski, Yannick
    Strube, Patrick
    Schwemmer, Christin
    Roll, Stephanie
    Zippelius, Timo
    Putzier, Michael
    SPINE, 2021, 46 (13) : 861 - 866
  • [8] Fundamentals and pitfalls of bone densitometry using dual-energy X-ray absorptiometry (DXA)
    Watts, NB
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 (11) : 847 - 854
  • [9] Vertebral morphometry by dual-energy X-ray absorptiometry (DXA) for osteoporotic vertebral fractures assessment (VFA)
    Diacinti, D.
    Guglielmi, G.
    Pisani, D.
    Diacinti, D.
    Argiro, R.
    Serafini, C.
    Romagnoli, E.
    Minisola, S.
    Catalano, C.
    David, V.
    RADIOLOGIA MEDICA, 2012, 117 (08): : 1374 - 1385
  • [10] Vertebral fracture assessment by new dual-energy X-ray absorptiometry
    Bazzocchi, Alberto
    Spinnato, Paolo
    Fuzzi, Federica
    Diano, Danila
    Morselli-Labate, Antonio M.
    Sassi, Claudia
    Salizzoni, Eugenio
    Battista, Giuseppe
    Guglielmi, Giuseppe
    BONE, 2012, 50 (04) : 836 - 841