One- and two-photon fluorescence resonance energy transfer microscopy to establish a clustered distribution of receptor-ligand complexes in endocytic membranes

被引:30
|
作者
Wallrabe, H
Stanley, M
Periasamy, A
Barroso, M
机构
[1] Univ Virginia, Dept Biol, WM Keck Ctr Cellular Imaging, Charlottesville, VA 22904 USA
[2] Chroma Technol Corp, Brattleboro, VT 05301 USA
关键词
MDCK cells; polymeric IgA receptors; energy transfer efficiency; FRET; clustering; one- and two-photon microscopy; FRET MICROSCOPY; MDCK CELLS; PROTEIN; RESOLUTION; TRANSCYTOSIS;
D O I
10.1117/1.1584444
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
One- and two-photon fluorescence resonance energy transfer (FRET) microscopy, using different bandwidth emission filters and a novel spectral spillover correction algorithm (PFRET algorithm), provides the basis for a quantitative approach to measure receptor clustering in endocytic membranes. Emission filters with wider bandwidth allow for an increased FRET signal and corresponding spillover. Treatment with the PFRET correction algorithm results in increasing correction levels and comparable energy transfer efficiency (E%) values, thus validating our algorithm-based approach. The relationship between E% and acceptor and donor levels and donor:acceptor (D:A) ratio is used to characterize the distribution of receptor-ligand complexes in endocytic membranes. in addition to the standard test for clustering (E%'s independence from acceptor levels), we describe a second parameter: the negative dependence of E% on increasing donor levels and D:A ratio. A donor geometric exclusion hypothesis is proposed to explain this phenomenon. One- and two-photon FRET microscopy assays show that polymeric IgA-receptor-ligand complexes are organized in clusters within apical endocytic membranes of polarized Madin-Darby canine kidney cells. (C) 2003 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:339 / 346
页数:8
相关论文
共 50 条
  • [1] Energy transfer efficiency based on one- and two-photon FRET microscopy differentiates between clustered and random distribution of membrane-bound receptor-ligand complexes
    Wallrabe, H
    Elangovan, M
    Burchard, A
    Barroso, M
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES II, 2002, 4620 : 310 - 318
  • [2] Comparison of one- and two-photon fluorescence resonance energy transfer microscopy
    Periasamy, A
    Elangovan, M
    Day, RN
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES, 2001, 4262 : 366 - 372
  • [3] Confocal fluorescence resonance energy transfer (FRET) microscopy to measure clustering of receptor-ligand complexes in endocytic membranes
    Wallrabe, H
    Burchard, A
    Periasamy, A
    Barroso, M
    MOLECULAR BIOLOGY OF THE CELL, 2002, 13 : 90A - 90A
  • [4] Characterization of one- and two-photon excitation fluorescence resonance energy transfer microscopy
    Elangovan, M
    Wallrabe, H
    Chen, Y
    Day, RN
    Barroso, M
    Periasamy, A
    METHODS, 2003, 29 (01) : 58 - 73
  • [5] Two-photon fluorescence: Resonance energy transfer
    Allcock, P
    Andrews, DL
    JOURNAL OF CHEMICAL PHYSICS, 1998, 108 (08): : 3089 - 3095
  • [6] Two-photon excitation in fluorescence polarization receptor-ligand binding assay
    Tirri, M
    Huttunen, R
    Toivonen, J
    Härkönen, P
    Soini, J
    Hänninen, P
    JOURNAL OF BIOMOLECULAR SCREENING, 2005, 10 (04) : 314 - 319
  • [7] Imaging cytosolic translocation of Mycobacteria with two-photon fluorescence resonance energy transfer microscopy
    Acosta, Yassel
    Zhang, Qi
    Rahaman, Arifur
    Ouellet, Hugues
    Xiao, Chuan
    Sun, Jianjun
    Li, Chunqiang
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (11): : 3990 - 4001
  • [8] One- and two-photon excited fluorescence of zinc(II), cadmium(II) complexes containing phenothiazine ligand
    Xue, ZM
    Tian, YP
    Wang, D
    Jiang, MH
    CHINESE CHEMICAL LETTERS, 2003, 14 (05) : 525 - 528
  • [9] Resonant transfer of one- and two-photon excitations in quantum dot–bacteriorhodopsin complexes
    V. A. Krivenkov
    P. S. Samokhvalov
    R. S. Bilan
    A. A. Chistyakov
    I. R. Nabiev
    Optics and Spectroscopy, 2017, 122 : 36 - 41
  • [10] One-photon versus two-photon excited fluorescence resonance energy transfer of GFP fusion proteins
    LaMorte, VJ
    Krasieva, TB
    Zoumi, A
    Forman, BM
    Solier, C
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES II, 2002, 4620 : 73 - 78