Determination of trace elements in biological samples treated with formic acid by inductively coupled plasma mass spectrometry using a microconcentric nebulizer

被引:28
作者
Tormen, Luciano [1 ]
Gil, Raul A. [2 ]
Frescura, Vera L. A. [1 ]
Dante Martinez, Luis [2 ]
Curtius, Adilson J. [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Inst Quim San Luis UNSL CONICET, San Luis, Argentina
关键词
ICP-MS; Biological samples; Formic acid solubilization; Trace elements; Microconcentric nebulizer; ATOMIC-ABSORPTION-SPECTROMETRY; HIGH-EFFICIENCY NEBULIZER; ETV-ICP-MS; PHOTOCHEMICAL VAPOR GENERATION; TETRAMETHYLAMMONIUM HYDROXIDE; ULTRASONIC NEBULIZATION; EMISSION-SPECTROMETRY; SELENIUM SPECIATION; ORGANIC-SOLVENTS; FLOW-INJECTION;
D O I
10.1016/j.sab.2010.09.007
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple and fast method for the determination of As, Ba, Cd, Co, Cu, Fe, Ga, Mn, Mo, Ni, Pb, Rb, Se, Sr, TI, U, V and Zn in biological samples by inductively coupled plasma mass spectrometry (ICP-MS), after sample solubilization with formic acid and introduction by a microconcentric nebulizer, is proposed. The sample is mixed with formic acid, kept at 90 T for one hour and then diluted with nitric acid aqueous solution to a 50%v/v formic acid and 1%v/v nitric acid final concentrations. The final sample solution flow rate for introduction into the plasma was 30 mu L min(-1). The optimized and adopted nebulizer gas flow rate was 0.7 L min(-1) and RF power was 800 W. These conditions are very different than those normally used when a conventional nebulizer is employed. Rodhium was used as internal standard. External calibration against aqueous standard solutions, without formic acid, could be used for quantification, except for As, Se and Zn. However, external calibration with 50% formic acid allows the determination of all analytes with high accuracy and it is recommended. The detection limits were between 0.0005 (TI) and 022 mg kg(-1) (Fe) and the precision expressed by the relative standard deviations (RSD) were between 0.2% (Sr) and 3.5% (Ga). Accuracy was validated by the analysis of four certified reference biological materials of animal tissues, comparing the results by linear regressions and by the t-test at a 95% confidence level. The recommended procedure avoids plasma instability and carbon deposit on the cones. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:959 / 966
页数:8
相关论文
共 41 条
[1]   Pressurized liquid extraction of organometals and its feasibility for total metal extraction [J].
Alonso-Rodriguez, E. ;
Moreda-Pineiro, J. ;
Lopez-Mahia, P. ;
Prada-Rodriguez, D. ;
Fernandez-Fernandez, E. ;
Muniategui-Lorenzo, S. ;
Moreda-Pineiro, A. ;
Bermejo-Barrera, A. ;
Bermejo-Barrera, P. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (05) :511-519
[2]  
Anderson R., 1991, SAMPLE PRETREATMENT
[3]  
[Anonymous], 2003, HDB CHEM PHYS
[4]   Can we trust mass spectrometry for determination of arsenic peptides in plants:: comparison of LC-ICP-MS and LC-ES-MS/ICP-MS with XANES/EXAFS in analysis of Thunbergia alata [J].
Bluemlein, Katharina ;
Raab, Andrea ;
Meharg, Andrew A. ;
Charnock, John M. ;
Feldmann, Jorg .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (07) :1739-1751
[5]   EFFECTS OF ORGANIC-SOLVENTS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
BOORN, AW ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1402-1410
[6]   APPLICATIONS OF ULTRASONIC NEBULIZATION IN THE ANALYSIS OF PETROLEUM AND PETROCHEMICALS BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
BOTTO, RI .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :51-57
[7]   Determination of mercury in organic solvents and gas condensates by μflow-injection -: inductively coupled plasma mass spectrometry using a modified total consumption micronebulizer fitted with single pass spray chamber [J].
Bouyssiere, Brice ;
Ordonez, Yoana Nuevo ;
Lienemann, Charles-Philippe ;
Schaumloffel, Dirk ;
Lobinski, Ryszard .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (09) :1063-1068
[8]   Characterization of an ultrasonic nebulizer membrane separation interface with inductively coupled plasma mass spectrometry for the determination of trace elements by solvent extraction - Invited lecture [J].
Brenner, IB ;
Zander, A ;
Plantz, M ;
Zhu, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :273-279
[9]   Sensitivity improvement in ICP MS analysis of fuels and light petroleum matrices using a microflow nebulizer and heated spray chamber sample introduction [J].
Caumette, Guilhem ;
Lienemann, Charles-Philippe ;
Merdrignac, Isabelle ;
Paucot, Hugues ;
Bouyssiere, Brice ;
Lobinski, Ryszard .
TALANTA, 2009, 80 (02) :1039-1043
[10]   Determination of Co, Cu, Fe, Mn, Ni and V in diesel and biodiesel samples by ETV-ICP-MS [J].
Chaves, Eduardo S. ;
Lepri, Fabio G. ;
Silva, Jessee S. A. ;
de Quadros, Daiane P. C. ;
Saint'Pierre, Tatiana D. ;
Curtius, Adilson J. .
JOURNAL OF ENVIRONMENTAL MONITORING, 2008, 10 (10) :1211-1216