A DFIG Sensorless Rotor-Position Detector Based on a Hysteresis Controller

被引:51
作者
Marques, G. D. [1 ]
Fernao Pires, V. [2 ]
Sousa, Sergio [2 ]
Sousa, Duarte M. [1 ]
机构
[1] Univ Tecn Lisboa, Inst Super Tecn, P-1049001 Lisbon, Portugal
[2] Polytech Inst Setubal, Super Tech Sch Setubal, Dept Elect Engn, P-2910761 Setubal, Portugal
关键词
Doubly fed induction generators (DFIGs); induction generators; sensorless; FED INDUCTION GENERATOR; FIELD-ORIENTED CONTROL; PHASE-LOCKED LOOP; MRAS OBSERVER; MACHINE; OPERATION; SPEED;
D O I
10.1109/TEC.2010.2070507
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A simple sensorless method for the detection of the mechanical rotor position of the wound-rotor induction machine in order to implement stator-flux orientation is described and evaluated in this paper. The method is based on the phase comparison of the actual and the estimated rotor currents using the classical model of the machine. It can be conceptually implemented in the rotor or in the stator reference frames. It has some similarity to the model reference adaptive system methodology, but uses a hysteresis comparator instead of a proportional integral (PI) controller. In this way, the method does not need parameter determination for the controllers and shows a considerable independence of parameter uncertainties. Simulation and experimental results show that the method is appropriate for the vector control of the doubly fed induction generator (DFIG) because it leads to the decoupling of active and reactive power chains. It is also appropriate for the control of the DFIG in transients like those when voltage dips occur.
引用
收藏
页码:9 / 17
页数:9
相关论文
共 21 条
[1]  
[Anonymous], 1990, CONTROL ELECT DRIVES
[2]  
BOGALECKA E, C REC 1993 EUR POW 8, V377, P224
[3]  
BOGALECKA E, 2002, EUR POW EL APPL EL M
[4]   MRAS observer for doubly fed induction machines [J].
Cárdenas, R ;
Peña, R ;
Asher, G ;
Clare, J ;
Cartes, J .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (02) :467-468
[5]   Rotor current based MRAS observer for doubly-fed induction machines [J].
Cárdenas, R ;
Peña, R ;
Proboste, J ;
Asher, G ;
Clare, J .
ELECTRONICS LETTERS, 2004, 40 (12) :769-770
[6]   Sensorless control of a doubly-fed induction generator for stand alone operation [J].
Cárdenas, R ;
Peña, R ;
Proboste, J ;
Asher, G ;
Clare, J .
PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, :3378-3383
[7]   A simple position-sensorless algorithm for rotor-side field-oriented control of wound-rotor induction machine [J].
Datta, R ;
Ranganathan, VT .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2001, 48 (04) :786-793
[8]   Adaptive Observer for Sensorless Control of Stand-Alone Doubly Fed Induction Generator [J].
Forchetti, Daniel G. ;
Garcia, Guillermo O. ;
Ines Valla, Maria .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (10) :4174-4180
[9]   Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder [J].
Hopfensperger, B ;
Atkinson, DJ ;
Lakin, RA .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2000, 147 (04) :241-250
[10]   Operation of a phase locked loop system under distorted utility conditions [J].
Kaura, V ;
Blasko, V .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (01) :58-63