Electrochemical bioassay coupled to LAMP reaction for determination of high-risk HPV infection in crude lysates

被引:26
作者
Izadi, Nasim [1 ]
Sebuyoya, Ravery [1 ,3 ]
Moranova, Ludmila [1 ,3 ]
Hrstka, Roman [1 ]
Anton, Milan [2 ]
Bartosik, Martin [1 ]
机构
[1] Masaryk Mem Canc Inst, Res Ctr Appl Mol Oncol RECAMO, Zluty Kopec 7, Brno 65653, Czech Republic
[2] Masaryk Univ, Med Fac, Univ Hosp Brno, Dept Obstet Gynecol, Obilni Trh 11, Brno 60200, Czech Republic
[3] Masaryk Univ, Fac Sci, Natl Ctr Biomol Res, Kamenice 5, Brno 62500, Czech Republic
关键词
HPV; Cervical cancer; Crude lysate; Electrochemistry; LAMPamplification; MEDIATED ISOTHERMAL AMPLIFICATION; DNA BIOSENSOR; GENOMIC DNA; ASSAY; PCR; DESIGN;
D O I
10.1016/j.aca.2021.339145
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical (EC) detection of DNA biomarkers represents an interesting tool in molecular oncology due to its sensitivity, simplicity, low cost or rapid times of measurement. However, majority of EC assays, same as most optical-based techniques, require preceding DNA extraction step to remove other cellular components, making these assays more laborious and time-consuming. One option to circumvent this is to use LAMP (loop-mediated amplification), an isothermal amplification technique that can amplify DNA directly in crude lysates in a short time at a constant temperature. Here, we coupled the LAMP reaction with EC readout to detect DNA from the two most common oncogenic human papillomavirus (HPV) types that cause cervical cancer in women, i.e. HPV 16 and HPV 18, directly in crude lysates without a need for DNA extraction step. We show that in crude lysates, the LAMP reaction was superior to PCR, with very good selectivity on a panel of cancer cell lines and with high sensitivity, enabling detection of HPV DNA from as few as 10 cells. As a proof of principle, we applied the assay to nineteen clinical samples both from uninfected women and from women suffering from cervical precancerous lesions caused by HPV 16 or HPV 18 genotypes. Clinical samples were simply boiled for 5 min in homogenization buffer without DNA extraction step, and amplified with LAMP. We obtained excellent concordance of our assay with PCR, reaching 100% sensitivity for both genotypes, 81.82% specificity for HPV 16 and 94.12% spec-ificity for HPV 18. Proposed assay could be a straightforward, simple, rapid and sensitive alternative for early diagnostics of precancerous cervical lesions. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 34 条
[11]   Identification of two independent X-autosome translocations in closely related mammalian (Proechimys) species [J].
da Silva, Wiliam Oliveira ;
Rodrigues da Costa, Marlyson Jeremias ;
Pieczarka, Julio Cesar ;
Rissino, Jorge ;
Pereira, Jorge C. ;
Ferguson-Smith, Malcolm Andrew ;
Nagamachi, Cleusayoshiko .
SCIENTIFIC REPORTS, 2019, 9 (1)
[12]   Design and application of a loop-mediated isothermal amplification assay for the rapid detection of Staphylococcus pseudintermedius [J].
Diribe, Onyinye ;
North, Sarah ;
Sawyer, Jason ;
Roberts, Lisa ;
Fitzpatrick, Noel ;
La Ragione, Roberto .
JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2014, 26 (01) :42-48
[13]   DNA-based label-free electrochemical biosensors: From principles to applications [J].
Hai, Xin ;
Li, Yuanfang ;
Zhu, Chengzhan ;
Song, Weiling ;
Cao, Jingyu ;
Bi, Sai .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 133
[14]   Development of a bio-inkjet printed LAMP test kit for detecting human African trypanosomiasis [J].
Hayashida, Kyoko ;
Nambala, Peter ;
Van Reet, Nick ;
Buscher, Philippe ;
Kawai, Naoko ;
Mutengo, Mable Mwale ;
Musaya, Janelisa ;
Namangala, Boniface ;
Sugimoto, Chihiro ;
Yamagishi, Junya .
PLOS NEGLECTED TROPICAL DISEASES, 2020, 14 (10) :1-17
[15]   Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M-avium, and M-intracellulare in sputum samples [J].
Iwamoto, T ;
Sonobe, T ;
Hayashi, K .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) :2616-2622
[16]   A new DNA sensor design for the simultaneous detection of HPV type 16 and 18 DNA [J].
Jampasa, Sakda ;
Siangproh, Weena ;
Laocharoensuk, Rawiwan ;
Yanatatsaneejit, Pattamawadee ;
Vilaivan, Tirayut ;
Chailapakul, Orawon .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 :514-521
[17]   Recent advances in biosensor development for the detection of cancer biomarkers [J].
Jayanthi, V. S. P. K. Sankara Aditya ;
Das, Asim Bikas ;
Saxena, Urmila .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :15-23
[18]   Point-of-care rapid detection of Vibrio parahaemolyticus in seafood using loop-mediated isothermal amplification and graphene-based screen-printed electrochemical sensor [J].
Kampeera, Jantana ;
Pasakon, Patiya ;
Karuwan, Chanpen ;
Arunrut, Narong ;
Sappat, Assawapong ;
Sirithammajak, Sarawut ;
Dechokiattawan, Nipaphorn ;
Sumranwanich, Thitinun ;
Chaivisuthangkura, Parin ;
Ounjai, Puey ;
Chankhamhaengdecha, Surang ;
Wisitsoraat, Anurat ;
Tuantranont, Adisorn ;
Kiatpathomchai, Wansika .
BIOSENSORS & BIOELECTRONICS, 2019, 132 :271-278
[19]   Rapid Detection of Zika Virus in Urine Samples and Infected Mosquitos by Reverse Transcription-Loop-Mediated Isothermal Amplification [J].
Lamb, Laura E. ;
Bartolone, Sarah N. ;
Tree, Maya O. ;
Conway, Michael J. ;
Rossignol, Julien ;
Smith, Christopher P. ;
Chancellor, Michael B. .
SCIENTIFIC REPORTS, 2018, 8
[20]   A colorimetric Loop-mediated isothermal amplification (LAMP) assay based on HRP-mimicking molecular beacon for the rapid detection of Vibrio parahaemolyticus [J].
Lee, Jeong-Eun ;
Mun, Hyoyoung ;
Kim, Se-Ri ;
Kim, Min-Gon ;
Chang, Ji-Yoon ;
Shim, Won-Bo .
BIOSENSORS & BIOELECTRONICS, 2020, 151