Sick building syndrome in relation to building dampness in multi-family residential buildings in Stockholm

被引:79
作者
Engvall, K [1 ]
Norrby, C
Norbäck, D
机构
[1] Univ Uppsala Hosp, Dept Med Sci Occupat & Environm Med, S-75185 Uppsala, Sweden
[2] Stockholm Off Res & Stat, Stockholm, Sweden
关键词
air pollution; building dampness; dwelling; mould growth; indoor environment; sick building syndrome (SBS); questionnaire;
D O I
10.1007/s004200000218
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: The aim was to study relationships between symptoms compatible with sick building syndrome (SBS) on one hand, and different indicators of building dampness in Swedish multi-family buildings on the other. Methods: In Stockholm, 609 multi-family buildings with 14,235 dwellings were identified, and selected by stratified random sampling. The response rate was 77%. Information on weekly symptoms, age, gender,population density in the apartment, water leakage during the past 5 years, mouldy odour, condensation on windows, and high air humidity in the bathroom was assessed by a postal questionnaire. In addition, independent information on building characteristics was gathered from the building owners, and the central building register in Stockholm. Multiple logistic regression analysis was applied, and adjusted odds ratios (OR) were calculated. adjusted for age and gender, population density, and selected building characteristics. Results: Condensation on windows, high air humidity in the bathroom, mouldy odour, and water leakage was reported from 9.0%, 12.4%, 7.7% and 12.7% of the dwellings, respectively. In total 28.5% reported at least one sign of dampness. All indicators of dampness were related to an increase of all types of symptoms, significant even when adjusted for age, gender, population density, type of ventilation system, and ownership of the building. A combination of mouldy odour and signs of high air humidity was related to an increased occurrence of all types of symptoms (OR = 3.7-6.0). Similar findings were observed for a combination of mouldy odour and structural building dampness (water leakage) (OR = 2.9-5.2). In addition, a dose-response relationship between symptoms and number of signs of dampness was observed. In dwellings with all four dampness indicators, OR was 6.5, 7.1, 19.9, 5.8, 6.1, 9.4, 15.0 for ocular, nasal, throat, dermal symptoms, cough, headache and tiredness, respectively. Conclusion: Signs of high air humidity, as well as of structural building dampness, are common in multi-family buildings in Stockholm. Reports of building dampness in dwellings is related to a pronounced increase of symptoms compatible with the SBS, even when adjusted for possible confounding by age, gender, population density, and building-related risk factors.
引用
收藏
页码:270 / 278
页数:9
相关论文
共 46 条
  • [1] ANDERSSON K, 1998, INDOOR AIR S, V4, P27
  • [2] APTER A, 1994, J ALLERGY CLIN IMMUN, V94, P277, DOI 10.1016/0091-6749(94)90087-6
  • [3] Björnsson E, 1998, INT J TUBERC LUNG D, V2, P1023
  • [4] ASTHMATIC SYMPTOMS AND INDOOR LEVELS OF MICROORGANISMS AND HOUSE-DUST MITES
    BJORNSSON, E
    NORBACK, D
    JANSON, C
    WIDSTROM, J
    PALMGREN, U
    STROM, G
    BOMAN, G
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 1995, 25 (05) : 423 - 431
  • [5] Boman G, 1996, INDOOR BUILT ENVIRON, V5, P270
  • [6] BORNEHAG CG, 1994, ANAL PATTERNS INDOOR, P23
  • [7] DAMP HOUSING AND ADULT RESPIRATORY SYMPTOMS
    BRUNEKREEF, B
    [J]. ALLERGY, 1992, 47 (05) : 498 - 502
  • [8] BRUNEKREEF B, 1994, AIR QUAL MG, V2, P189
  • [9] CAIN WS, 1995, OCCUP MED, V10, P133
  • [10] INDOOR AIR-QUALITY AND HEALTH - REPRODUCIBILITY OF RESPIRATORY SYMPTOMS AND REPORTED HOME DAMPNESS AND MOLDS USING A SELF-ADMINISTERED QUESTIONNAIRE
    DALES, RE
    SCHWEITZER, I
    BARTLETT, S
    RAIZENNE, M
    BURNETT, R
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (01): : 2 - 7