High speed, line-scanning, fiber bundle fluorescence confocal endomicroscopy for improved mosaicking

被引:28
作者
Hughes, Michael [1 ]
Yang, Guang-Zhong [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hamlyn Ctr Robot Surg, London SW7 2AZ, England
来源
BIOMEDICAL OPTICS EXPRESS | 2015年 / 6卷 / 04期
基金
英国工程与自然科学研究理事会;
关键词
MICROSCOPY; TISSUE;
D O I
10.1364/BOE.6.001241
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A significant limitation of fiber bundle endomicroscopy systems is that the field of view tends to be small, usually only several hundred micrometers in diameter. Image mosaicking techniques can increase the effective image size, but require careful manipulation of the probe to ensure sufficient overlap between adjacent frames. For confocal endomicroscopes, which typically have frame rates on the order of 10 fps, this is particularly challenging. In this paper we demonstrate that line-scanning confocal endomicroscopy can, by use of a high speed linear CCD camera, achieve a frame rate of 120 fps while maintaining sufficient resolution and signal-to-noise ratio to allow imaging of topically stained gastrointestinal tissues. This leads to improved performance of a cross-correlation based mosaicking algorithm when compared with lower frame-rate systems. (C) 2015 Optical Society of America
引用
收藏
页码:1241 / 1251
页数:11
相关论文
共 23 条
[1]   Fluorescence endomicroscopy with structured illumination [J].
Bozinovic, Nenad ;
Ventalon, Cathie ;
Ford, Tim ;
Mertz, Jerome .
OPTICS EXPRESS, 2008, 16 (11) :8016-8025
[2]   Micromachined scanning confocal optical microscope [J].
Dickensheets, DL ;
Kino, GS .
OPTICS LETTERS, 1996, 21 (10) :764-766
[3]  
Erden MS, 2013, IEEE INT CONF ROBOT, P1205, DOI 10.1109/ICRA.2013.6630725
[4]   CONFOCAL MICROSCOPY THROUGH A FIBEROPTIC IMAGING BUNDLE [J].
GMITRO, AF ;
AZIZ, D .
OPTICS LETTERS, 1993, 18 (08) :565-567
[5]   Confocal Endomicroscopy: Instrumentation and Medical Applications [J].
Jabbour, Joey M. ;
Saldua, Meagan A. ;
Bixler, Joel N. ;
Maitland, Kristen C. .
ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (02) :378-397
[6]  
Juskaitis R, 1997, SCANNING, V19, P15, DOI 10.1002/sca.4950190102
[7]   Axial response of high-resolution microendoscopy in scattering media [J].
Koucky, Michael H. ;
Pierce, Mark C. .
BIOMEDICAL OPTICS EXPRESS, 2013, 4 (10) :2247-2256
[8]  
Le Goualher G, 2004, LECT NOTES COMPUT SC, V3217, P761
[9]   Multispectral confocal microendoscope for in vivo and in situ imaging [J].
Makhlouf, Houssine ;
Gmitro, Arthur F. ;
Tanbakuchi, Anthony A. ;
Udovich, Josh A. ;
Rouse, Andrew R. .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (04)
[10]   Subcellular-resolution molecular imaging within living tissue by fiber microendoscopy [J].
Muldoon, Timothy J. ;
Pierce, Mark C. ;
Nida, Dawn L. ;
Williams, Michelle D. ;
Gillenwater, Ann ;
Richards-Kortum, Rebecca .