Compressed sensing with gradient total variation for low-dose CBCT reconstruction

被引:3
作者
Seo, Chang-Woo [1 ]
Cha, Bo Kyung [2 ]
Jeon, Seongchae [2 ]
Huh, Young [2 ]
Park, Justin C. [3 ]
Lee, Byeonghun [4 ]
Baek, Junghee [5 ]
Kim, Eunyoung [5 ]
机构
[1] Yonsei Univ, Coll Hlth Sci, Dept Radiat Convergence Engn, Wonju, South Korea
[2] Korea Electrotechnol Res Inst, Adv Med Device Res Ctr, Ansan, South Korea
[3] Univ Florida, Dept Radiat Oncol, Gainesville, FL USA
[4] Inha Univ, Sch Informat & Commun Engn, Inchon, South Korea
[5] Soongsil Univ, Sch Global Media, Seoul, South Korea
关键词
Iterative reconstruction; Compressed sensing; Total variation; Gradient total variation; Low-dose; CBCT; BEAM COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; ALGORITHMS; DETECTOR; CT;
D O I
10.1016/j.nima.2014.12.106
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes the improvement of convergence speed with gradient total variation (GTV) in compressed sensing (CS) for low-dose cone-beam computed tomography (CBCT) reconstruction. We derive a fast algorithm for the constrained total variation (TV)-based a minimum number of noisy projections. To achieve this task we combine the GTV with a TV-norm regularization term to promote an accelerated sparsity in the X-ray attenuation characteristics of the human body. The GTV is derived from a TV and enforces more efficient computationally and faster in convergence until a desired solution is achieved. The numerical algorithm is simple and derives relatively fast convergence. We apply a gradient projection algorithm that seeks a solution iteratively in the direction of the projected gradient while enforcing a non-negatively of the found solution. In comparison with the Feldkamp, Davis, and Kress (FDK) and conventional TV algorithms, the proposed GTV algorithm showed convergence in <= 18 iterations, whereas the original TV algorithm needs at least 34 iterations in reducing 50% of the projections compared with the FDK algorithm in order to reconstruct the chest phantom images. Future investigation includes improving imaging quality, particularly regarding X-ray cone-beam scatter, and motion artifacts of CBCT reconstruction. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:570 / 573
页数:4
相关论文
共 15 条
[1]   Fast Gradient-Based Algorithms for Constrained Total Variation Image Denoising and Deblurring Problems [J].
Beck, Amir ;
Teboulle, Marc .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2009, 18 (11) :2419-2434
[2]   Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT [J].
Bian, Junguo ;
Siewerdsen, Jeffrey H. ;
Han, Xiao ;
Sidky, Emil Y. ;
Prince, Jerry L. ;
Pelizzari, Charles A. ;
Pan, Xiaochuan .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) :6575-6599
[3]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509
[4]   Compressed sensing based cone-beam computed tomography reconstruction with a first-order method [J].
Choi, Kihwan ;
Wang, Jing ;
Zhu, Lei ;
Suh, Tae-Suk ;
Boyd, Stephen ;
Xing, Lei .
MEDICAL PHYSICS, 2010, 37 (09) :5113-5125
[5]  
Debatin M, 2012, IEEE NUCL SCI CONF R, P2295
[6]   Compressed sensing [J].
Donoho, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) :1289-1306
[7]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[8]   ALGEBRAIC RECONSTRUCTION TECHNIQUES (ART) FOR 3-DIMENSIONAL ELECTRON MICROSCOPY AND X-RAY PHOTOGRAPHY [J].
GORDON, R ;
BENDER, R ;
HERMAN, GT .
JOURNAL OF THEORETICAL BIOLOGY, 1970, 29 (03) :471-&
[9]   ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA [J].
HUDSON, HM ;
LARKIN, RS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) :601-609
[10]   GPU-based fast low-dose cone beam CT reconstruction via total variation [J].
Jia, Xun ;
Lou, Yifei ;
Lewis, John ;
Li, Ruijiang ;
Gu, Xuejun ;
Men, Chunhua ;
Song, William Y. ;
Jiang, Steve B. .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (02) :139-154